Controls EMGRT1 Скачать руководство пользователя страница 8

                       CONTROLS, INCORPORATED 

C O N T R O L   S Y S T E M S   &   S O L U T I O N S  

                                                                                                            
                                                                                                                  - 7 - 

 

9) Controller Menus 

9.1  The control panel has menus to view engine and controller parameters.  These menus are accessible via a 

four-button pad located on the face of the control panel.  

9.2   Available Menus 

Sender Configuration: 

Speed signal and overspeed settings. 

Control Functions

:  

 

Glow plug and auto start settings. 

Discrete Input Configurations

 (View 

only) 

9.3  Menu Access & Navigation 

9.3.1 Entering Menus 

1. Press and hold the MENU key & simultaneously press the ENTER key. 

9.3.2 Navigation 

1. Press MENU to select the next menu category. 
2. Press UP to view or edit the specific screen(s) in the category. 
3. Use the UP and DOWN keys to move among the screens in the category. 
4. Press MENU at any time within a category to jump back to the inner ring 

  

9.3.3 Password Entry     

The password screen is provided to restrict the edit of sensitive values to authorized personnel. 
Not entering a password permits viewing, but no editing of restricted values.  Upon encountering 
the password screen, a series of dashes will be displayed. To enter the password: 
 
1. Press ENTER to begin editing. The password zeroes will be bracketed. 
2. Use the UP and DOWN keys to set the first (leftmost) digit, as you would for a cylinder 

combination lock. 

3. Press ENTER to freeze that digit and move to the next one on the right. 
4. Repeat steps 2 and 3 until all digits have been set. After the final digit is set, the brackets 

automatically disappear. 

5. Press the UP key to proceed to the next screens. 
 
If the correct password was entered earlier, navigating back over the password entry screen will 
show the password as a row of stars. The password approval state is retained as long as the 
panel is powered up. 

9.3.4 Editing 

Some screens permit parameter changes. 
1. Press ENTER to start editing. The value on the screen will be surrounded by brackets.  On 

password-protected screens, brackets appear only when the correct password was entered 
earlier. 

2. Use the UP and DOWN keys to adjust the value. In the case of a selection list, the various 

possible selections will be shown in a ring. In the case of a variable number, press the 
appropriate key to step up/down. For larger changes, press and hold the UP or DOWN key.  
(The value will step faster as the key is held down. Stepping will stop when preset value limits 
are reached or the key is released.) 

3. Press ENTER to save the new value. The brackets will disappear. 
4. To skip the edit and retain the old value, press MENU instead of ENTER. 

    

9.3.5 Exiting 

1. Press and hold the MENU key & simultaneously press the ENTER key. 

Leaving during editing will abandon the edit and the old value will be retained. Exiting has no effect 
on the password approval. To clear the approved password state, power cycle the panel. 

 

 

Содержание EMGRT1

Страница 1: ...er EMGRT1 Customer The Gorman Rupp Company Revision 2 0 ______________________________________________________________________________________________________________________________________ Copyright...

Страница 2: ...ngine When engine is started manually the controller will operate To stop the engine the key needs to be switched to the Off position B Automatic Engine Start Stop 1 For auto start place key in the Au...

Страница 3: ...is plug play with all engine and accessory connectors incorporated into the enclosure 1 3 The backlit digital display is 1 H x 4 W with two rows of 16 characters Character height is approximately 1 4...

Страница 4: ...time display parameter are Water Temperature Degrees F Battery Voltage Engine RPM Fuel Level if fuel level sender installed Oil Pressure PSI Engine Hours 2 3 Menu Enter Buttons To access and scroll me...

Страница 5: ...ws that are removable for internal access 3 3 The controller is plug play with all engine and accessory connectors incorporated into the enclosure These connections include Engine Harness Connector 16...

Страница 6: ...6 1 4 Low Fuel Level Fuel Level is measured below 1 for 5 seconds 7 Controller Specific Alarms 7 1 The controller monitors additional system inputs directly including 7 1 1 Emergency Stop Digital An E...

Страница 7: ...Pin C Oil Pressure Pin F Battery Pin G Battery to Alt Excite Pin R Battery to Fuel Solenoid Pin J Battery to Pre Heat Relay Pin P MPU Pin A MPU 8 2 Float Connection The controller is connected to the...

Страница 8: ...ss ENTER to freeze that digit and move to the next one on the right 4 Repeat steps 2 and 3 until all digits have been set After the final digit is set the brackets automatically disappear 5 Press the...

Страница 9: ...y default settings can be reset in two ways 9 4 1 Reset Procedure See picture below 1 Turn the key to the Auto position 2 Open the enclosure to access the circuit board 3 Make connection between two p...

Страница 10: ...Digital Input 1 Low Water Level Na Yes Digital Input 2 Low Oil Level Na Yes PA Pre Alarm A Alarm AWRO Alarm While Running Only RPM Calibration Speed Set Procedure Your control system may need to be ca...

Страница 11: ...x 3 MPU 18 Battery Positive Relay Common 4 MPU 19 5 Fuel Level Sender 240 33 ohm 20 Alternator Excite D 6 Low Water Level Switch 21 Power Crank Solenoid 10A DC Max 7 Low Oil Level Switch 22 Fault Comm...

Страница 12: ...S 11 10 2 TTL Outputs 10 2 1 When active the outputs sink to 0 VDC 10 2 2 When not active the outputs stay at 5 VDC 39 Low Oil Pressure Shutdown 40 High Temp Shutdown 41 Low Fuel Level Shutdown 42 Ov...

Страница 13: ...harging Battery System The Self Charging Battery System SCBS included with this control is designed to maintain a high level of battery capacity during extended periods of standby operation However ca...

Страница 14: ...ions must be met if warranty is valid Seller will not be liable for any damage done by unauthorized repair work unauthorized misapplication in non suitable environment In no event shall the Seller be...

Отзывы: