3.2.3.1
USER menu
As alternative to the two Standard methods, the system allows creating a customized test
procedure, setting the following parameters:
Fig. 3-15
CALCULATION:
selection of the type of calculation (MEDIAN, MEAN, MEAN W/O OUTLIERS e.g.
discarding non meaningfull values):
Fig. 3-16
•
MEDIAN: the final result of the test is calculated as the median value considering all
the readings belonging to this set of measures
•
MEAN: the final result of the test is calculated as the average value considering all
the reading belonging to this set
•
MEAN W/O OUTLIERS: the final result of the test is calculated as the average
value considering all the reading belonging to this set, discarding non-significant
values, according to the criterion given by the EN 12504-2 standard (6 units).
NUMBER OF READINGS:
Allows setting the number of rebounds of the customized test set that will be considered
for the calculation method above selected.
Fig. 3-17
Содержание 58-C0181/DGT
Страница 1: ...MANUALE DI ISTRUZIONI INSTRUCTION MANUAL 58 C0181 DGT Digital Concrete Hammer ...
Страница 2: ......
Страница 57: ...Manuale di Istruzioni Instruction Manual 58 C0181 DGT Rev 2 EN 04 02 2015 53 Notes ...
Страница 58: ...Manuale di Istruzione Instruction Manual 04 02 2015 58 C0181 DGT Rev 2 EN 54 Notes ...
Страница 59: ...Manuale di Istruzioni Instruction Manual 58 C0181 DGT Rev 2 EN 04 02 2015 55 Notes ...
Страница 60: ...Manuale di Istruzione Instruction Manual 04 02 2015 58 C0181 DGT Rev 2 EN 56 Notes ...