OPERATION
INTELLISTAT TS
TM
MONITOR DESCRIPTION
- High / Low Input Voltage
- High / Low Output Voltage
- High Output Volt-Amperes
- High / Low Output Frequency
- High / Low Battery Voltage
- High Battery Charge Current
FEATURES
INVERTER STATUS AND ALARM INDICATORS
- LCD display of all electrical parameters.
- NFPA compliant automatic battery testing and logging.
- User programmable automatic system testing.
- System alarm annunciation.
- Audible alarm with alarm silence.
- Alarm status display.
- Email / Cell phone status notification.
- Optional fax / email / voice / web page reporting of test results.
- Date and time display.
- Auto logging of test results / events.
- Multi layer password protection.
- Remote monitoring capabilities.
- Programmable local interfaces.
- Logs up to 50 events.
- Non volatile clock and memory.
- Programmable alarm set points.
- System Normal
- General Alarm
- System on Battery
- Low Battery Warning
- Low Battery Shutdown
- Battery Test in Process
- Output Volt-Amperes
- Output Watts
- Output Power Factor
- Auto Battery Test Failed / Passed
- Output Circuit Breaker Open
- Charger Fail / DC Open Circuit
- System in Static or Manual Bypass
- REPO Active
MEASURED PARAMETERS
- Battery Charger Current
- Battery Capacity Remaining
- Input Voltage
- Output Voltage
- Output Current
- Output Percent Load
- Output Frequency
- Battery Voltage
ADVANCED DIGITAL MONITORING -
The user-friendly Intellistat TS
TM
monitor provides quick, full access to all of
the monitor features, and also allows all programming to be done directly from the monitor. An easy to read LCD
indicates all the electrical parameters, as well as the functional status of the inverter. A virtual keypad allows the
entry of date / time values, system set points and password information into the monitor, without the need for an
external computer and cable.
The Intellistat TS
TM
-
Intelligent status monitoring a UPS’s operational status is critical for maintaining operational
efficiency, as well as for monitoring the power feeding the computer systems. With this in mind, Controlled Power
Company designed the model
“ES”
with state of the art monitoring features to provide complete system diagnostics
and testing with access to all electrical system parameters.
AUTOMATIC SYSTEM TESTS -
The Intellistat TS
TM
Monitor automatically performs a user defined (date and time)
30 second system test every 30 days; as well as a user defined (date and time) annual 60 second system test. For
all of these tests, the Intellistat TS
TM
Monitor logs the test results with the date and time, as well as a “pass” or “fail”
indication.
MANUAL SYSTEM TESTS -
The Intellistat TS
TM
Monitor
also allows the user to manually invoke a user defined
system test for 30 seconds.