Utility Tower Series UPS
UP350TE/UP500TE/UP500E/UP750E
User Manual
K01-U350E0A-01
SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to
unpack, install, or operate your UPS.
This equipment can be operated by any individuals with no previous training.
The socket-outlet shall be installed near the equipment and easily accessible.
During the installation of this equipment it should be assured that the sum of the leakage currents of
the UPS and the connected loads does not exceed 3.5mA.
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should be
therefore disconnected in the plus and minus pole at the quick connectors of the battery when
maintenance or service work inside the UPS is necessary.
Do not dispose of batteries in a fire, the battery may explode.
Do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes.
INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
UPS Unit; PowerPanel
®
Software Disk
¯
1; Serial Interface Cable (DB-9)
¯
1; Telephone Cable
¯
1;
IEC-IEC Power Cord
¯
2; User Manual; PowerPanel
®
Software User Manual.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR
EQUIPMENT
1. Insure that the equipment plugged into the battery power-supplied outlets does not exceed the
UPS unit’s rated capacity (350VA/210W for UP350TE, 500VA/300W for UP500TE, 500VA/325W
for UP500E, 750VA/450W for UP750E). If rated unit capacities are exceeded, an overload
condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
2. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert
Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only
calculates the maximum amount of VA that the equipment can use, not what is typically used by
the equipment at any one time. Users should expect usage requirements to be approximately 60%
of below value.
TO ESTIMATE POWER REQUIREMENTS
1. Watts (W) x 2.0 = VA or Amps (A) x 230 = VA
2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual
requirements. There are many factors that can affect the amount of power that your computer
system will require. The total load that you will be placing on the battery-powered outlets should
not exceed 80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
1. Connect the equipment to your UPS outlets. The IEC-IEC power cords coming with the unit are
used to connect your computer and monitor to the UPS. Items such as copiers, laser printers,
vacuums, space heaters, or other large electrical devices should not be connected to the UPS.
Please make sure that the total loads of your equipments are less than the maximum total power
load of your UPS.
2. Use your computer power cord to connect the UPS to a wall outlet. Please avoid using extension
cords and adapter plugs. (To maintain optimal battery charge, leave the UPS plugged in at all
times.)
3. Press the UPS power button to turn it on. The “Power On” indicator will be illuminated in “Green”.
4. Install your software and accessories. To use the software, simply connect the enclosed serial
interface cable to the serial port on the UPS and an open serial port on the computer.
BASIC OPERATION
FRONT PANEL AND REAR PANEL DESCRIPTION
◆
Power Switch
UP350TE/UP500TE UP500E/UP750E
Press the power button to turn the UPS ON or OFF.
◆
Power On Indicator
This LED is illuminated when the utility condition is normal and the UPS outlets are
providing “clean power”, free of surges and spikes.
◆
Using Battery Indicator
This illuminates during utility failure, indicating that the battery is supplying power to
the battery-power supplied outlets.
◆
Battery Backup and Surge Protection Outlets
The UPS provides battery powered and surge protected
outlets for connected equipment to insure temporary
uninterrupted operation during a power failure and against
surges and spikes.
◆
Surge Protection Outlets
The UPS provides surge protected
only outlet for connected
equipments against surges and spikes.
◆
Serial Port to PC
This port allows connection and
communication from the DB-9 serial on the computer
to the UPS unit. The UPS communicates its status to the PowerPanel
®
software. This
interface is also compatible with the UPS service provided by
Windows 98, Windows
ME, Windows NT, Windows 2000, Windows XP, Windows Server 2003.
◆
Ethernet (RJ-45) Network Protection Ports
These ports are the protection for your computer network cable.
BATTERY REPLACEMENT AND STORAGE
CAUTION!
Read and follow the
IMPORTANT SAFETY INSTRUCTIONS
before servicing the battery.
Service the battery under the supervision of personnel knowledgeable of batteries and their
precautions. Keep unauthorized personnel away from batteries.
If you have questions,
contact
your dealer or call the number in this manual
for information on battery replacement.
CAUTION! Use only the specified type of battery.
See your dealer for replacement batteries.
CAUTION!
The battery may present the risk of electrical shock.
Do not dispose of batteries in a
fire
, as it may explode. Follow all local ordinances regarding proper disposal of batteries.
CAUTION!
Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes
and may be toxic.
CAUTION!
A battery can present a high risk of short circuit current and electrical shock.
Take the
following prec
autions before replacing the battery
:
1. Remove all watches, rings or other metal objects.
2. Only use tools with insulated handles.
3.
DO NOT
lay tools or other metal parts on top of battery or any battery terminals.
4. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of
ground.
CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK!
The likelihood of such shock will be reduced if such grounds are removed during installation
and maintenance (applicable to a UPS and a remote battery supply not having a grounded
circuit).
5.
Batteries are consider
HAZARDOUS WASTE
and must be disposed of properly. Contact your
local government for more information about proper disposal and recycling of batteries.
6. Turn off and unplug all connected equipment.
7. Turn the UPS off and unplug it from the AC power source.
8
.
Turn the UPS upside down.