Rolling Door Opener RDO-1V3 Tri-Tran
+
Installation Instructions
Controll-A-Door
®
Diamond PD
and Firmamatic
TM
OR
Important Safety Instructions
T o Incr
ease Force Pr
essure
a. Hold down the FORCE MARGIN SET button
.
b. While holding the FORCE MARGIN SET button, pr
ess the PLUS (+) button. Each
press will incr
eases the force mar
gin.
c. The OPEN LIMIT LED will flash each time the PLUS (+) button is pr
essed to indicate
an increase in for
ce.
d. If the OPEN LIMIT
LED flashes continuously when
the PLUS (+) button is being
pressed, this indicates that the maximum for
ce setting has been reached.
e. T
est the force again as per T
esting Close Cycle and Testing Open Cycle.
To Recall Factory Set For
ce
a. Holding down the FORCE MARGIN SET button and the LIMIT SET button for two
seconds.
b. Release both buttons. The default setting should now be r
ecalled.
Doc #: 161013_00
Part #: 79097
Released: 28/03/14
WARNING!
•
The door may operate unexpectedly, therefore do not allow anything to stay in the path of
the door.
•
When operating the manual release while the door is open, the door may fall rapidly due
to weak or broken springs, or due to being improperly balanced.
•
The drive must not be used with a door incorporating a wicket door, unless the drive cannot
be operated with the wicket door open.
•
The drive is intended to be installed at least 2.5m above the floor.
•
Do not disengage the opener to manual operation with children/persons or any objects
including motor vehicles within the doorway.
•
If the door is closing and is unable to re-open when obstructed, discontinue use. Do not
use a door with faulty obstruction sensing
•
When using auto close mode, a
Photo Electric beam
must be fitted correctly and tested
for operation at regular intervals.
Extreme caution
is recommended when using auto
close mode.
All safety rules
must be followed.
ELECTROCUTION!
•
Place opener in protected area so that it does not get wet.
•
Do not spray with water .
•
Disconnect the power cord
from mains power before making any repairs or removing
covers. Only
experienced
service personnel should remove covers from the opener.
•
If the power supply cord is damaged, it
must
be replaced by an Automatic Technology
service agent or suitably qualified person.
•
Connect the opener to a properly
earthed
general purpose 240V mains power outlet
installed by a qualified electrical contractor.
CAUTION:
Emergency Access
•
If garage has no pedestrian entrance door, an emergency access device should be
installed. This accessory allows manual operation of the garage door from outside in case
of power failure.
Muscular strain
•
Practice correct lifting techniques (carton weighs approx 9kgs)
•
Practice correct lifiting techniques when required to lift the door as per installation instructions.
Fall from ladder
•
Ensure ladder is the correct type for job.
•
Ensure ladder is on flat firm ground that will take the weight without the legs sinking.
•
Ensure user has 3 points of contact while on ladder.
Crush injury from unsecured
door
•
Place a 2 metre exclusion zone around area under the door while it is unsecured.
•
Do not move under a door while it is on the door support (or ladder)
•
Follow the installation instructions
•
Fit door support (or ladder) snugly under door before removing bracket.
•
Ensure door support (or ladder) is on flat ground
Garage Door
•
Examine the door installation, in particular, springs and mountings for signs of wear, damage
and imbalance.
•
The garage door must be
well balanced.
Sticking or binding doors must be repaired by a
qualified garage door installer prior to installation of the opener.
•
Remove or disengage
all garage door locks and mechanisms prior to installation of the
opener.
Entanglement
•
Never plug in and operate opener prior to installation.
•
Keep hands and loose clothing clear of door and guides at all times.
Entrapment under
operating door
•
DO NOT
operate the opener unless the garage door is in full view and free from objects
such as cars and children/people. Make sure that the door has finished moving before
entering or leaving the garage
•
In order for the opener to
sense
an object obstructing the door way, some
force
must be
exerted on the object. As a result the object, door and/or person may suffer minor
damage
or
injury.
•
Ensure the garage door is in good working order by undertaking regular servicing.
•
Install the optional wall transmitter in a location where the garage door is visible, but out
of the reach of children at a height of at least 1.5m.
•
Photo Electric beams must be installed if the closing force at the bottom edge of the door
exceeds 400N (40kg)
This automatic garage door opener is designed and tested to offer safe service provided it is
installed and operated in strict accordance with the following safety rules. Failure to comply with
the following instructions may result in death, serious personal injury or property damage.
34-36 Marigold St, Revesby, NSW, Australia ABN 25 010 473 971
P: 13 62 63 W: www.bnd.com.au
WARNING!
Take car
e when testing or adjusting the
Safety Obstruction For
ce. Excessive for
ce may
cause
SERIOUS PERSONAL INJURY and/or PROPER
TY
DAMAGE.
Testing Close Cycle
a.
Press the pr
ogrammed transmitter to open the door.
b.
Place a piece of timber approximately 40mm high on the
floor directly under the door
.
c.
Press the pr
ogrammed transmitter to close door.
d.
The door should strike the object and re-open.
Testing Open Cycle
a.
Press the transmitter to close the door
.
b.
Press again to open the door
.
c.
When the door reaches appr
oximately half way, fir
mly grab
the door’s bottom rail - the door should stop.
d.
If the door does not reverse r
eadily when closing, or stop
when opening, the force may be excessive and need
adjusting.
40mm block
of wood
Safety Obstruction Forces
WARNING!
If the door fails these tests, put the opener into
manual mode, only operate the door by hand and call for
service.
WARNING!
Photo electric beams must be installed if the closing
force at the bottom edge of the door exceeds 400N (40kg) for
ce.
WARNING!
Please test the manual release mechanism to
ensure that the manual r
elease is easy to operate. No more
than 15 kg of force should be r
equired to disengage the door
using the manual release cor
d. If excessive force is r
equired
reset the close limit position.
Adjusting Safety Obstruction Force
The Safety Obstruction Force is calculated automatically
during setup. Adjusting this is normally only necessitated by
environmental conditions such as windy or dusty ar
eas, and areas
with extreme temperatur
e changes.
Symptom
Possible cause
Remedy
The opener does not work
from the transmitter
The opener does not have power
The battery in the transmitter is flat
Transmitter does not contain
Tri-T
ran
+
Technology
The opener has been put into “Vacation
Mode”
The transmitter button is not programmed to
operate the door.
Door Code LED is flashing yet the opener is
not working.
Plug a device of similar voltage (e.g. a hairdryer) into
the power point and check that it is OK
Replace the battery
Check that the transmitter has grey buttons and the
model number on the back displays V2. Contact
dealer for support if otherwise.
Tur
n off “V
acation Mode”
(Section 8.3, step e of Home Owners Manual)
Code in the transmitter
Ensure the corr
ect button on the transmitter is being
pressed.
One transmitter works but
the other/s do not
Faulty transmitter
Flat battery
Replace transmitter
Replace battery
The motor is running but the
door remains stationary
The opener is disengaged
Re-engage the opener
The transmitter range varies
or is restricted
Variations ar
e normal depending on
conditions e.g. temperature or exter
nal
interference
The battery life is exhausted
Position of the transmitter in the motor
vehicle
Make sure you can see the door when you use the
transmitter.
Check the battery status by pressing a button (flashing
or no light requir
es battery to be changed)
Aim the transmitter through the windscr
een.
The Courtesy light does not
work
LED has failed
Change LED.
The door reverses for no
apparent r
eason
This may occur occasionally from
environmental conditions such as ar
eas that
are windy
, dusty or have extreme temperatur
e
changes.
If Safety beams are installed they may be
partially obstructed.
Ensure the door runs smoothly befor
e increasing the
force pr
essure.
Ensure the beam path is not obstructed. Check the
Alignment.
The door stops or moves
very slowly.
Garage door in poor condition e.g. springs
may be broken.
(Optional Battery Back Up Accessory) The
batteries may have little OR no charge
Check the door’s operation.
Connect mains power and leave the batteries to
charge. The batteries may take 24 to 48 hours to r
each
their maximum charge capacity
.
The SERVICE LED has
started to flash and is
beeping numerous times
A Fault has been detected. The fault will
be active each time an attempt is made to
operate the door.
Record opener function (How many beeps?) then pr
ess
the LIMIT SET button once to reset the opener
. If the
fault continues to be tripped contact 1300 736 410 for
support.
The Open (Green) LED and
Close (Red) LED are flashing
alternatively
Opener is overloaded
Check the doors operation by disengaging the motor
and ensuring the door runs smoothly. If necessary make
door adjustments or contact your door professional.
The Open (Green) LED
continues to flash
Door obstructed when opening
Clear away any obstructions and test door opens
correctly
. (If door is damaged, contact your door
professionl).
The Close (Red) LED
continues to flash
Door obstructed when closing
Limits may be cleared
Clear away any obstructions and test door closes
correctly
. (If door is damaged, contact your door
professional).
Remove all power sources (including the battery
backup). Wait till all lights ar
e out (10-15 secs), then
reconnect power
. If Red LED is flashing, limits are not
set. Reset Limits.
Troubleshooting Guide
T o Decr
ease Force Pr
essure
a. Hold down the FORCE MARGIN SET button.
b. While
holding the FORCE
MARGIN SET button, pr
ess the MINUS (-) button.
Each
press will decr
ease the force mar
gin.
c. The CLOSE LIMIT LED will flash each time the MINUS (-) button is pr
essed to
indicate a decrease in for
ce.
d. If
the CLOSE
LIMIT LED
flashes continuously
when the
MINUS (-)
button is
being
pressed, this indicates that the minimum for
ce setting has been reached.
e. T
est the force again as per T
esting Close Cycle and T esting Open Cycle.
Tools Required
•
Ladder
•
Adjustable Wrench
•
Socket set
•
Drill
Open to Installation
Section
Power Supply
Properly earthed 3 pin single -phase power is required.
a.
WARNING!
A portable power generator is
not recommended due to spikes, surges and
fluctuations in the supply.
Unsuitable Door Types
The drive must not be used with a door incorporating
a wicket door, unless the drive cannot be operated
with the wicket door open. The fitting of an opener to
doors with removable mullions is not recommended.
Sideroom
The minimum sideroom required from the edge of the
door curtain is 41mm to the inside of the door bracket,
and 85mm to the wall. If a Battery Backup is to be fitted,
at least 135mm to the bracket is required.
Therefore the recommended sideroom from the edge of
the door curtain is 95mm to the inside of the door bracket,
and 135mm to the wall as per diagram.
85
41
135
95
Minimum Side room
Recommended Side room
Position
The opener can be installed on either the right - or left hand side of the
door (when viewed from the inside the garage). The opener is factory set
for right hand side installation.
The opener must be installed in a dry position that is protected from the
weather. Moisture or corrosion damage is not covered by the Warranty.
•
Screwdrivers
•
Marker Pen
•
Door Stand
Kit Contents
1.
1 x RDO-1V3 drive unit
2. 2 x Locking Bar Covers
3. 2 x TB-6 Transmitters (RDO-1V3)
OR
2 x TB-5 Transmitters (Firmamatic)
4. 1 x Collar Kit
5. 1 x Weight Bar
Fastner Bag
6. 2 x Nilock Nut
7. 2 x 2 x 3/16 x 1/2 flat washers
8. 2 x Pan Head Screw M4 x 50
9. 2 x Self Tapping Screw M10 x 32
10. 2 x Washer 6.4 x 20.6 x 1.2 GAL
Accessory Pack
11. 2 x Extension Fork
12. 2 x Flat Washer 107D 6.4 x 20.5 x 1.6
13. 2 x Hex Serration Head Screw M6 x 45
14. Wall Mount Transmitter (RDO-1V3 only)
1
2
3
5
6
7
8
13
12
11
9
4
10
34-36 Marigold St, Revesby, NSW
, Australia ABN 25 010 473 971
P: 13 62 63 W: www
.bnd.com.au
To Recalculate For
ce Margins
a.
Press and hold the FORCE MARGIN SET Button for six (6) seconds, the beeper
will sound once
.
b.
The door will start to move and re-calculate for
ce margins. The door can move
between the open and close limit positions up to four (4) times (depending on
the position of the door and the power up condition).
c.
A single beep will be heard once the pr
ocess is complete.
d.
T est the for
ce again as per T esting Close Cycle and T
esting Open Cycle.
Important Note:
Only Tri-Tran
+
Technology Transmitters
and Keypads are compatible with this
RDO-1V3 product.
14