*
M’Ax Advanced User Guide
38
Issue Number: 4
www.controltechniques.com
8
Menu 6 Parameters - Sequencer Functions, AC Supply Loss
Modes
Parameter
Range(
ô
)
Default(
ð
)
Type
6.01
Stop mode selector
0 ~ 2
2
RW
Txt
P
6.03
AC supply loss mode selector
0 ~ 1
0
RW
Uni
P
6.08
Hold zero speed select
0 ~ 1
1
RW
Bit
6.15
Drive enable
0 ~ 1
1
RW
Bit
6.20
Powered-up time (years, days)
00.00 ~ 9.365 y.d
RO
Uni
S
P
6.21
Powered-up time (hours, minutes)
00.00 ~ 23.59 h.m
RO
Uni
S
P
6.31
Sequencing bit JOG FORWARD
0 ~ 1
0
RW
Bit
6.32
Sequencing bit JOG REVERSE
0 ~ 1
0
RW
Bit
6.33
Sequencing bit FORWARD/REVERSE
0 ~ 1
0
RW
Bit
6.34
Sequencing bit RUN
0 ~ 1
0
RW
Bit
6.35
FORWARD LIMIT switch
0 ~ 1
0
RW
Bit
6.36
REVERSE LIMIT switch
0 ~ 1
0
RW
Bit
6.44
Active supply indicator
0 ~ 1
RO
Bit
6.48
DC-bus threshold voltage
0 ~ 600
400
RW
Uni
6.49
Controlled-stop enabled indicator
0 ~ 1
RO
Bit
6.50
UV warning threshold
0 ~ 600
400
RW
Uni
Содержание M'Ax
Страница 9: ... M Ax Advanced User Guide 6 Issue Number 4 www controltechniques com ...
Страница 47: ... M Ax Advanced User Guide 44 Issue Number 4 www controltechniques com ...
Страница 48: ... 45 M Ax Advanced User Guide www controltechniques com Issue Number 4 Figure 9 1 Menu 7 software diagram ...
Страница 49: ... M Ax Advanced User Guide 46 Issue Number 4 www controltechniques com ...
Страница 73: ... M Ax Advanced User Guide 70 Issue Number 4 www controltechniques com ...