Control iD iDProx Скачать руководство пользователя страница 2

ABA Track II 

The ABA Track II protocol uses 4 wires: CARDPRES, 
CLK, DATA and GND. The CARDPRES output remains 
at  the  logical  level  1  while  there  is  no  card  to  be 
read.  When  a  card  is  close  to  the  reader,  the 
CARDPRES  output  goes  to  logical  level  0  and  the 
data  is  read  from  DATA  each  time  the  CLK  input 
goes from the logical level 1 to logical level 0. When 
all the data is sent, the CARDPRES output goes back 
to the logical level 1 and data is not read anymore. 
The wiring diagram for this case is presented below: 

 

 

 Warning! The Wiegand protocol is faster and 

the most efficient option 
 

 You cannot use this protocol with the iDBox 

controller. 
 
RS-232 

 
The  RS232  protocol  usually  uses  3  cables:  RX,  TX 
and 

 

GND. 

Data is transmitted by the TX output and received 
by  the  RX  input.  No  synchronization  signal  is 
required in this case. 
The output of this protocol, through this reader, is 
TTL,  i.e.  a  logical  level  1  is represented by  5V  and 
logical level 0 is represented by 0V, with no negative 
voltage. 
The wiring diagram is presented below: 

 

 

Technical Specifications 

Power Supply 

External power supply 12VDC /1A (not included). 

1.2W nominal consumption. 

Identification 

Proximity card: ASK, FSK, PSK or Mifare. 

⚠ 

The  type  of  card  must  be  defined  before 

purchasing.   

Range 

ASK: 15cm | FSK: 10cm | PSK: 10cm | Mifare: 6cm 

Communication 

 Wiegand output, may be configured for ABA Track 
II. 

 RS232 TTL shared output   

Interface 

Yellow, green and red LED controlled by an input.  

4kHz and 70dbA Buzzer @100mm controlled by an 
input.   

Dimensions and weight 

Slim Model  

20mm x 95mm x 51mm (H x W x L) 

103g 

Compact Model 

22mm x 130mm x 55mm (H x W x L) 

102g 

Assembly Instructions

 

iDProx Compact 

 

 

iDProx Slim

 

 

Manual – iDProx – Versão 2.4 EN – Control iD 2017© 

Отзывы: