![Control iD iDProx Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/control-id/idprox/idprox_manual_2658598002.webp)
ABA Track II
The ABA Track II protocol uses 4 wires: CARDPRES,
CLK, DATA and GND. The CARDPRES output remains
at the logical level 1 while there is no card to be
read. When a card is close to the reader, the
CARDPRES output goes to logical level 0 and the
data is read from DATA each time the CLK input
goes from the logical level 1 to logical level 0. When
all the data is sent, the CARDPRES output goes back
to the logical level 1 and data is not read anymore.
The wiring diagram for this case is presented below:
⚠
Warning! The Wiegand protocol is faster and
the most efficient option
⚠
You cannot use this protocol with the iDBox
controller.
RS-232
The RS232 protocol usually uses 3 cables: RX, TX
and
GND.
Data is transmitted by the TX output and received
by the RX input. No synchronization signal is
required in this case.
The output of this protocol, through this reader, is
TTL, i.e. a logical level 1 is represented by 5V and
logical level 0 is represented by 0V, with no negative
voltage.
The wiring diagram is presented below:
Technical Specifications
Power Supply
External power supply 12VDC /1A (not included).
1.2W nominal consumption.
Identification
Proximity card: ASK, FSK, PSK or Mifare.
⚠
The type of card must be defined before
purchasing.
Range
ASK: 15cm | FSK: 10cm | PSK: 10cm | Mifare: 6cm
Communication
Wiegand output, may be configured for ABA Track
II.
RS232 TTL shared output
Interface
Yellow, green and red LED controlled by an input.
4kHz and 70dbA Buzzer @100mm controlled by an
input.
Dimensions and weight
Slim Model
20mm x 95mm x 51mm (H x W x L)
103g
Compact Model
22mm x 130mm x 55mm (H x W x L)
102g
Assembly Instructions
iDProx Compact
iDProx Slim
Manual – iDProx – Versão 2.4 EN – Control iD 2017©