SPECIFICATIONS

Display: 

Triple 4 digit LCD. 

Over Range Indication: 

OL

 - appears.

Low Battery Indicative: 

 shows up when tire 

battery’s voltage below the 

operating voltage.

Sampling Rate : 

about 1 time per second

Power Requirement:  6pcs 1.5V size AAA alkaline 

batteries or 9V AC Adaptor / 

500mA minimum.

Battery Life: 

Approx. 90 hours. (Interval 

printing = 60 minutes, excluding 

beeper). 160 hours (without 

printing & beeper).

Printing Interval: 

6 sec to 59 win 59 sec 

Operating Temperature 

and Humidity: 

0 to 50°C (32 to 122°F) below 

95% RH 

Storage Temperature 

and Humidity: 

–10 to 60°C (14 to 140°F) 

below 70% RH Dimensions 

(Meter): 

193 (L) x 74 (W) x 37(H) mm

(Probe): 

160 (L) x 13(D) mm/1m cable

Weight: 

Approx. 430g with batteries & 

thermo-paper.

Accessories 

Carrying case, Instruction 

manual, Batteries, 2 Rolls of 

thermo-paper, type K probe.

Printer: 

Thermo-printing tape with 16 

characters per line using 38mm 

width plain thermo-paper.

Electrical Specifications

Humidity:

Range: 

30%RH to 95%RH

Resolution: 0.1%RH
Temperature (T1):

Range: 

–20 to 60°C (–4 to 140°F)

Resolution: 

0.1°C / 0.1°F

Dew Point:

Range: 

–44.0 to 58.5°C (–47.2 to 137.3°F)

NAME OF PARTS AND POSITION

1.  LCD: Measured values, until, symbols, and decimal 

points are displayed.

2.  (CIRCLE): Key for power on/off

3.  [C/F]: Key for exchanging temperature unit °C and °F.

4.  [PRINT]:

 

Key for start printing current data. The format  

  as below:

LINE 1  20:12:01  02-21

LINE 2   

58.9%RH

LINE 3  td 

15.7°C

LINE 4  T1 

24.3°C

LINE 5  T2 

24.8°C

Line 1: printing time hour minute: second, month- day.

Line 2: printing humidity value.

Line 3: printing Dew point value.

Line 4: printing T1 temperature value.

Line 5: printing T2 temperature value (K-Type).

 Press this button for 2 seconds, the printer will  

  enter interval printing status, and won’t stop  

  unless this button is pressed again or FEED  

  button is pressed. 

5.  DC 9V VAC adaptor input jack. 

6.  [FEED] PAPER (Fig-2):

 Key for moving forward thermo-paper  

  one line. 

 Perform force stop printing, and skip any  

  printing data.

7.  [DEW POINT]: Key for changing humidity in 

dew-point display.

8.  [MAX/MIN]:

 

Press this key one time to enter  

  maximum/minimum record mode, the  

  “REC” symbol is displayed.

 Press this key to display the maximum  

  reading (“MAXREC” symbol displayed),  

  the minimum reading (“MINREC” symbol  

  displayed) in cycle.

 Press this key 2 seconds to exit this mode.

9.  [HOLD]: Key for holding the display reading and press 

again to exit.

10. 

: Key for start/stop set-up parameters mode. 

Parameters (in sequence):

ON/OFF 

(interval printing enable or disable). 

TIME INTV  (printing interval ranging from  

00m:06s to 59m:59s).

INTV► 

(Interval printing start time ranging from 

00h:00m to 23h:59m).

INTV

 

(Interval printing stop time ranging from 

00h:00m to 23h:59m).

TIME 

(Calendar setting year, month, day, hour, 

minute).

11. 

 DOWN: Key for decreasing the value of  

parameters.

12. 

 RIGHT: Key for moving to the desired next 

parameter setting.

13. 

 UP: Key for increasing the value of  

parameters setting.

14. 

 LEFT: Key for moving to the desired forward 

parameter setting.

15.  Way out for thermo-paper.

16.  Type K temperature probe jack.

17.  Battery cabinet and cover: 6pcs 1.5V size AAA 

alkaline batteries.

18.  Humidity (including temperature) probe.
LCD DISPLAY

1.  Dew point measurement indicator.

2.  Preset interval printing function ON indicator.

3.  Low battery indicator.

4.  Printing indicator.

5.  Interval printing start time setting indicator.

6.  Interval printing stop time setting indicator.

7.  Calendar time indicator.

8.  Interval printing indicator.

9.  T1 measurement indicator.

10.  T1 measurement value (NTC).

11.  T2 measurement indicator.

12.  T2 measured value (Type-K).

13.  Temperature measurement units.

14.  Humidity measurement units.

15.  Recording indicator.

16.  Minimum measurement value indicator.

17.  Maximum measurement value indicator.

18.  Data hold indicator.

19.  Humidity and dew point temperature measured 

value

PRECAUTIONS AND PREPARATIONS FOR  

MEASUREMENT
1.  Before operating this instrument, please examine it 

to make sure no shipping damage occurs. Otherwise 

notify your dealer.

2.  Save all packing materials until you are sure that this 

unit can normally operate.

3.  Be sure that batteries are correctly placed in the case 

or adaptive 9V Adaptor is in correct connection.

4.  An unsecured battery cover will cause error  

measuring.

5.  To avoid battery leakage problem, remove batteries if 

this meter will not be used for a long time.

6.  Do not use or store this meter outside the operating/

storage environment.

OPERATING PROCEDURE

1.  This meter can be supplied with batteries or DC 9V 

AC Adaptor. If using batteries:
Remove the rear cover, and install batteries, pay  

attention to the polarity of battery socket. If using 9V 

Adaptor, make sure that it is in good connection to 

the Adaptor socket of the meter. Choose the K-type 

temperature probe for your application and insert it 

into T2 the temperature probe socket. Insert Humidity/

Temperature (T1) probe into T1 the meter socket.

2.  Press the   button to power on the meter, the current 

date and time will display about 3 seconds. If “---“ ap-

pears, it indicates no probe or the probe is broken.

3.  T1 indicates room temperature, T2 indicates K-type 

thermocouple test value.

4.  Printing date:

Press [PRINT] one time to print one set date.

If need continuous printing, press and hold down 

PRINT button, until LCD display “INTV” mark and 

enter continuous interval printing mode, the printer will 

print data as follows:

INTV 

00:06   

Interval printing time, minute : second

10:55:19  08-16   

Printing time, hour:minute:second,  

 

   month:day

62.7 

%RH   

Humidity test value and unit.

td 

19.8  °C  Dew point and unit

T1 

27.6  °C  Room temperature test value and unit.

T2 

26.5  °C  K-type thermocouple test value  

 

 

 

and unit.

10:55:25 08-16

62.7 %RH

td 

19.8 °C

T1 

27.6 °C

T2 

26.5 °C

10:55:31 08-16

62.7 %RH

td 

19.8 °C

T1 

27.6 °C

T2 

26.5 °C

10:55:37 08-16

62.8 %RH

td 

19.8 °C

T1 

27.6 °C

T2 

26.5 °C

Press [PRINT] or [FEED] key to exit printing mode.

 

When the meter is powered on, if the printing function 

setting is “ON”, and now time is interval printing start 

time, the meter will enter to continuous interval print-

ing mode and start printing.

*  Press (PRINT) or (FEED) key to exit printing mode.

*  The interval printing function worked only when the 

start printing time is earlier than the stop printing time, 

and interval print time can not be longer than  

24 hours.

Caution:

 Before printing, please check thermo-paper is 

not clipped by thermo-paper cover, if anything interrupts 

the printer, the mater will shut off the printer power, and  

” symbol flickers.

SETTING MODE

Press “

” button to enter setting function, re-press this 

button can select setting parameters in circle (printer 

on or off, interval printing time, start printing time and 

calendar setting). The modifier parameter will flicker until 