Thread any relay wires, contact wires, and external thermistor
wires from the wall through the openings in the tray and to the
terminal block.
T
C1
C2
Cm
C3
C4
PWR Cm
Note:
The two
Cm
(common/ground) pins are connected and
can be used interchangeably.
9
Insert and tighten the mounting screws.
Note:
You may optionally choose to use robust two-sided
tape to mount the tray assembly to the wall or other flat
surface, as long as the tape won’t prevent the back of the
tray from sitting flush against the mounting surface.
10
Connect the wires from the tray to the terminals in the cover,
matching the proper wires to the target terminal locations. The
pin/terminal definitions are defined within Composer Pro. See
“Configuring” on the next page. (Pins Cm and PWR are used for
optional external power connections.)
Important!
When using multiple external contact sensors, or
when using an external contact sensor along with an external
thermistor, you MUST connect each device to one of the Cm
pins in addition to the appropriate sensor or thermistor pin
to make a proper wiring connection. See the “Sample wiring
configurations” section of this document for examples.
11
Attach the cover assembly to the tray:
A.
Align the cover edge’s two
latching tabs with corresponding
tab receivers on the tray’s edge.
B.
Close the cover by rocking
it toward the other end of the
tray until it snaps into place with
the tray.
A
B
12
For Zigbee to IR, connect any IR emitters to the two IR ports, then
affix the emitter head to the IR window on the device to control
(such as a TV).
Connecting alternate DC power
Although a power adapter is included, you may elect to instead
connect an alternate 5-24V DC or AC power source to pins
Cm
-
PWR
.
Connect DC positive polarity to pin
PWR
, and negative to pin
Cm
.
T
C1
C2
Cm
C3
C4
PWR Cm
DC power
3/8˝
(9.5 mm)
+
–
Configuring
Connections
Static connections
Some connections in the driver are static in that they are always
available regardless of any settings/options. These include the
two IR connections, IR Output 1 and IR Output 2, and the internal
contact.
Dynamic connections
Other connections in the driver are dynamic in that the
connections will appear based on certain options—in particular,
the
IO Options
property.
If you change to another IO option, any
connections created in the original IO option will be broken
.
To configure your device:
1
Add the device to your Composer Pro project. When prompted to
identify the device, press the ID button on the face of the cover
four times. The green LED blinks twice to confirm the ID has been
sent to the Control4 system.
- OR -
In Composer Express, add a device into the project, scan for
Zigbee devices, then press the ID button on the face of the cover
four times.
2
In the driver’s
Properties
tab, view or configure the settings
explained below under “Properties,” then click
Set
to the right of
the setting after each change.
3
Configure each relay’s power up state. This is the state you want
the relay to adopt after a device reboot. For example, after a
power outage (resulting in a device reboot), you may want the
garage door to default to closed, the window coverings to be
restored to their last known state, and the fireplace to be turned
off.
Tip:
Two SPST relays can optionally be linked to simulate a
single SPDT relay. However, unlike a true SPDT relay, both
relays will open during a power failure.