Log Mode:

 Activates logging of diagnostic information. 

The log level is set in the above property. Options include 

Off

Print

 (to the window), 

Log

 (to the Director Log), and 

Print and Log

 (both). Default is 

Off

• 

Driver Version:

 (Read only) Shows the version number of 

the driver currently in use. 

• 

Device Status:

 (Read only) Shows the current status of 

the product, whether online or offline. However, in some 

cases, the device may not report its status immediately, 

such as when the device is rebooting. 

• 

Firmware Version: 

(Read only) Shows the version 

number of the firmware currently in use on the device. 

The firmware will be updated automatically over the air 

when the Control4 OS is updated and when that update 

includes a new firmware version for this device. 

• 

Bootloader Version:

 (Read only) Shows the version 

number of the firmware currently in use on the device. 

The bootloader can only be updated by Control4, so this 

property is for support/diagnostic information only. 

Battery properties

• 

Battery Level: 

Reports the charge level of the battery. 

When the batteries on a Z2C are low, a low battery alert 

can be configured using the Z2C’s battery level. When the 

batteries are very low, the LED behavior and temperature 

and humidity reporting become unreliable.

Humidity properties

• 

Local Humidity:

 (Read only) Shows the relative humidity 

measured where the device is located. The value is shown 

as a percentage. 

• 

Local Humidity Offset:

 The humidity sensor provides 

accuracy of +/- 4% relative humidity. Adjusting the 

Local Humidity Offset

 can result in increased inaccuracy 

of relative humidity reporting without using humidity 

calibration equipment for validation.

Temperature properties

• 

Temperature Scale:

 Sets which scale is used to 

calculate the temperature used in the 

Local

 and 

Remote 

Temperature

 properties described below, and affects only 

the 

Properties

 tab’s settings. Options include 

Fahrenheit

 

and 

Celsius

. Default is 

Fahrenheit

.

• 

Local Temperature:

 (Read only) Shows the most recent 

reported temperature recorded by the internal thermistor. 

The scale of the temperature is determined by the 

Temperature Scale

 property. 

• 

Local Temperature Offset

—Modifies the reported local 

temperature to account for environmental variances. The 

temperature can be changed downward or upward by a 

maximum of 20 degrees. The default is 

0

 (no correction). 

• 

Remote Temperature:

 (Read only) Shows the most recent 

reported temperature recorded by the remote thermistor. 

The scale of the temperature is determined by the 

Temperature Scale

 property. 

• 

Remote Temperature Offset

—Modifies the reported  

remote temperature (the temperature recorded by 

an external thermistor) to account for environmental 

variances. (When multiple temperature sensors are 

located in the same room, you may notice each sensor 

shows a slightly different reading. This results from normal 

manufacturing variances in temperature sensors and the 

device’s position/location in the room.) The temperature 

can be changed downward or upward by a maximum of 

20 degrees. The default is 

0

 (no correction).

Contacts properties

• 

Contact Internal Status:

 (Read only) Shows the status of 

the static connection for the internal contact.

• 

Contact 1-4 Status: 

(Read only) Represents the status of 

the wired contacts.

Checkin properties

• 

Checkin Interval: 

Defines how often the device checks 

with the controller to see if the controller is requesting 

information from the device, such as version information, 

or if the controller is trying to update any settings on 

the device, such as the check in interval. A check in can 

also be manually triggered by pressing the button on the 

Z2C. The check-in interval can be configured to check in 

with the controller between 10 minutes and 4 hours. The 

default is 10 minutes. Increasing the check-in interval will 

increase the battery life of the device.

• 

Last Checkin Time: 

(Read only) Shows the most recent 

time the device checked in with the controller.

• 

Missed Checkin Limit:

 Sets the number of times the 

checkin is missed before triggering the “Missed Checkin” 

programming event.

Actions tab

Buttons located on the 

Actions 

tab allow you to view version 

and diagnostic information.

• 

Version Information:

 This action button will display the 

versions of the driver’s Base Template and Template, as 

well as the Boot Loader to the 

Lua Output

 window of the 

Lua

 tab. The 

Log Mode

 property does not have to be set 

to Print to display this information to the window.

• 

Diagnostic Information:

 This action button will display the 

following information to the 

Lua Output

 window of the 

Lua

 tab (the 

Log Mode

 property does not have to be set 

to Print to display this information to the window): device 

ZigBee MAC address, ZigBee mesh PAN id, Template 

Version, Base Template Version, Boot Loader Version, 

ZigBee Node ID.