Before You Install in a Third-Party DIN Rail Panel

Install the third-party panel according to the third-party instructions.

Installation Instructions

Install in a Control4 Panel

With the Ethernet port facing right, hold the Bus Ethernet Gateway upright 

and angle it to the right so that the right side of the module fits onto the rail 

in the panel.

With the right side already in place, push forward on the left side of the Bus 

Ethernet Gateway to snap it onto the rail (see Figure 2).

Figure 2. Snap on the Bus Ethernet Gateway - Control4 Panels

NOTE

:

 To remove the module, push the module toward the left side, pull 

out from the left side., and remove it from the right side.

Install in a Third-Party Panel

With the Ethernet port facing up, hold the module lengthwise and angle it up 

so that the top side of the module fits onto the rail. 

With the top side already in place, rotate the module down to snap it onto the 

rail (see Figure 3).

Figure 3. Snap on the Bus Ethernet Gateway - Third-Party Panels

NOTE

To remove the module, push the module toward the bottom, rotate 

the module up, and lift it off.

On the top of the Bus Ethernet Gateway, connect the Ethernet CAT5 cable to 

the RJ-45 port.

Install the other modules in the panel as defined in their respective installation 

guides.

Wiring Diagrams

For information about bus wiring details, refer to the 

Keypad Bus Wiring Guide

.

Operations and Configuration

Button Taps

The button taps are defined in the table below.

Function

Button Taps

Identify

4

Factory Reset

9

Reboot

15

LED Indicators

The indicator lights on the front of the Bus Ethernet Gateway communicate the 

status of the device.

Indicator

Color

Status

Notes

Status

Blue

Power On

Black

No Power

Link/Activity

Solid Green

Link

Orange

Activity

Flashing Green 

Firmware is updating

Flashing gets faster 
as the  
update proceeds

Reset Button

NOTE:

 

 The Reset button is recessed and must be pressed using a paper 

clip or similar device. A single click of the 

Reset

 button is equivalent to 

powering the Bus Ethernet Gateway off and back on.

Regulatory/Safety Compliance 

To review regulatory information for your particular Control4 products, see 

the information located on the Control4 website at: http://www.control4.com/

regulatory/.

Warranty 

For complete warranty information, including details on consumer legal rights as 

well as warranty exclusions, review the Warranty card or visit www.control4.com/

warranty.

About this Document