CONTRASTECH Mars Series Скачать руководство пользователя страница 15

- 15 -

AcquisitionStart

AcquisitionStart

Starts the Acquisition of the device. The
number of frames captured is specified
by AcquisitionMode.

AcquisitionStop

AcquisitionStop

Stops the Acquisition of the device at
the end of the current Frame. It is
mainly used when AcquisitionMode is
Continuous but can be used in any
acquisition mode.

AcquisitionFrameCount

AcquisitionFrameCount

Min: 1

Max: 255

MultiFrames acquisition mode. Sets the
number of frames to acquire when a
valid trigger is received.

AcquisitionLineRate

AcquisitionLineRate

Controls the acquisition rate (in Hertz)
at which the frames are captured.

AcquisitionLineRateEnable

AcquisitionLineRateEnable

False/True

Enables setting the camera's acquisition
frame rate to a specified value

AcquisitionStatusSelector

AcquisitionStatusSelector

AcquisitionTriggerWait

FrameTriggerWait

Selects the internal acquisition signal to
read using

AcquisitionStatus

.

Device is currently waiting for a trigger
to capture one or more frames.

Device is currently waiting for a frame
trigger.

AcquisitionStatus

AcquisitionStatus

True

/

False

Reads the state of the internal
acquisition signal selected using

AcquisitionStatusSelector.

TriggerSelector

TriggerSelector

Acquisition

Start/Frame

Start/ Line Start

Selects which type of trigger to
configure .

TriggerMode

TriggerMode

Off
On

Controls the enable state of the
selected trigger.

(The selected trigger is turned off.)
(The selected trigger is turned active.)

TriggerSoftware

TriggerSoftware

Generates an internal trigger. This
feature is available when

TriggerMode

is set to

ON

and

TriggerSource

is set

to

Software

.

Trigger Source

Trigger Source

Specifies the internal signal or physical
input line to use as the trigger source.
The selected trigger must have its

TriggerMode

set to

ON

.

Trigger Activation

Trigger Activation

RisingEdge

Select the activation mode for the
selected Input Line trigger source.

The trigger is considered valid on

the rising edge of the line source signal

Содержание Mars Series

Страница 1: ...Mars Line Scan GigE Camera User Manual Using iCentral with Mars Line Scan GigE Cameras...

Страница 2: ...other equipment connected to our camera Handle this camera with care Do not abuse the camera Avoid striking shaking etc The camera could be damaged by improper handling Do not open the housing and do...

Страница 3: ...a Installation 7 3 iCentral Installation 7 4 iCentral Panes Description 10 4 1 Tool Bar 10 4 2 Visibility 11 4 3 Parameters Pane 12 4 3 1 Device Control 12 4 3 2 Image Format Control Descriptions 12 4...

Страница 4: ...ce Compact appearance 62 62 35mm On board buffer 256MB for data transmission and image reload under burst mode Support API trigger External trigger Free Run mode and other trigger mode Support sharpne...

Страница 5: ...5 1 3 2 Interface Description The description of each interface as shown in Figure 1 2 Figure 1 2 Interface Description...

Страница 6: ...is connected with the device free mode with image transmission Slow Flashing Blue Using trigger mode Red Blue Flashing Alternately Red and Blue Firmware is upgrading Abnormal Red Steady Red Device mal...

Страница 7: ...e installation position Connect the camera with right lens 2 Connect the camera to the PC network card by Gigabit Ethernet cable CAT5E or CAT6 3 Choose one of the following power supply methods DC pow...

Страница 8: ...8 Note Please check the following item...

Страница 9: ...f there is a new camera in the network it is required to click refresh in order to refresh the device list 5 Double click the device or click button for device connection and disconnection Explanation...

Страница 10: ...e iCentral are described in the figure below 4 1 Tool Bar File For user configuration User can do the following operations open open recent save and save as Tool bar Parameters Pane Message Window Con...

Страница 11: ...ow the instruction to change data 4 2 Visibility All camera features have a Visibility attribute which defines its requirement or complexity The states vary from Beginner features required for basic o...

Страница 12: ...anging all acquisition parameters supported by the acquisition device Parameters in gray are read only either always or due to another feature being disabled Parameters in black are user set in iCentr...

Страница 13: ...ixels ReverseX ReverseX False True Flip horizontally the image sent by the device The Region of interest is applied after the flipping PixelFormat PixelFormat Mono8 Mono10 Mo no10Packed Mono1 2 Mono12...

Страница 14: ...s to capture during an acquisition and the way the acquisition stops Frames are captured continuously with AcquisitionStart until stopped with the AcquisitionStop command One frame is captured for eac...

Страница 15: ...using AcquisitionStatus Device is currently waiting for a trigger to capture one or more frames Device is currently waiting for a frame trigger AcquisitionStatus AcquisitionStatus True False Reads th...

Страница 16: ...ight ResultingLineRateAbs ResultingLineRateAbs Indicates the absolute value of the maximum allowed acquisition frame rate The absolute value is a float value that indicates the maximum allowed acquisi...

Страница 17: ...tures Display Name Feature Values Description LineSelector LineSelector Selects the physical line or pin of the external device connector to configure LineMode LineMode Selects the physical line or pi...

Страница 18: ...ectionLevel LineDetectionLevel Threshold3V3 Threshold5V LineDebouncingPeriod LineDebouncingPeri od Min 3 40282e 38 Max 3 40282e 38 Default in nanosecond ns 4 3 5 EventControl The following table descr...

Страница 19: ...a Min 0 Max 3 99998 Controls the gamma correction of pixel intensity This is typically used to compensate for non linearity of the display system such as CRT 4 3 7 LUTControl The following table descr...

Страница 20: ...iveLinkCount GEVActiveLinkCount Indicates the current number of active logical links GEVInterfaceSelector GEVInterfaceSelector Selects which logical link to control GEVMACAddress GEVMACAddress MAC add...

Страница 21: ...IP Configuration is not defined Device IP Address Configuration is set to Persistent IP static Device IP Address Configuration is set to DHCP Dynamic Host Configuration Protocol Network requires a DH...

Страница 22: ...ndicates the number of message channels supported by this device GevStreamChannelCount GevStreamChannelCount Indicates the number of stream channels supported by this device GevHeartbeatTimeout GevHea...

Страница 23: ...elSelector Selects the stream channel to control GevSCPInterfaceIndex GevSCPInterfaceIndex Index of the logical link to use GevSCPHostPort GevSCPHostPort Controls the port of the selected channel to w...

Страница 24: ...ion IP address from which a GVSP receiver may receive data stream Static IP Configuration Configures the following parameters in TransportLayerControl GevCurrentIPConfigurationLLA True GevCurrentIPCon...

Страница 25: ...ccess Reports the last user set executed by the device from a user set load command or as a result of a device reset 4 3 10 CounterAndTimerControl The following table describes each Counter and Timer...

Страница 26: ...hift DigitalShift Min 0 Max 4 Sets the value of the selected digital shift control FPNcalibrationStatus FPNcalibrationStatus Fixed pattern noise correction calibration status FPNAlgorithmSelector FPNA...

Страница 27: ...27 Hangzhou Contrstech Co Ltd Add No 11 Xiyuan 8th Road West Lake District Hangzhou 310030 China TEL 86 571 89712238 Fax 400 8266 163 01460 Web site www contrastech com E mail market contrastech com...

Отзывы: