background image

2.6. Mounting the tray

-

Centre on tab and lower into place (fig. 4).

2.7. Door closing pressure

Figure 5
The closing latch rotates around a pressure screw
positioned cam.

-

Loosen pressure screw 1.

-

Turn cam to desired position.

-

Tighten pressure screw 1.

2.8. Pre-utilisation check

-

Check that the glasses are not damaged.

-

Check that the smoke passages are not obstructed by
packaging or removable parts.

-

Check that the seals of the smoke-line are in good
condition.

-

Check that the doors close correctly.

-

Check that all removable parts are correctly installed.
(grates, tray, etc.)

2.9. Soot Doors

It will be necessary to have a soot door to enable the
chimney to be swept. This may either be in the actual
brickwork of the chimney or in the register plate. Various
type and positions of soot doors are shown in figure 3.

2.10. Commissioning

On completion of the installation and after allowing a
suitable period of time for the fire cement and mortar to
dry out, the stove should be lit and checked to ensure
that smoke and fumes are taken from the appliance up
the chimney and emitted safely. Also check all joints
and seals.

Installation instructions

 

Figure 4 - Fixing the ash lip tray

1 - Pressure screw

2 - Cam

Figure 5 - Door closing pressure

Continental "La Parisienne" - ref. : 124 03 01 - 124 05 01 - 124 07 01

6

Technical manual "286"

Содержание 124 03 01

Страница 1: ...43 43 43 Fax 03 28 43 43 99 RC Hazebrouck 445750565B Subject to modifications Continental Room heater La Parisienne 124 03 01 124 05 01 124 07 01 How to install use and maintain your stove Norme NF D 35 301 Description of the appliance Installation instructions Operating instructions Spare parts Warranty certificate FR EN NL ES PT PL PL PL PL PL ...

Страница 2: ... CONTENTS Page Page FRANCO BELGE congratulates you on your choice FRANCO BELGE which has been granted the ISO 9001 certification guarantees the quality of its appliances and is committed to meet its customers needs FRANCO BELGE which can boast a 75 year experience in the industry of heating devices uses state of the art technologies to design and manufacture its whole range of products This docume...

Страница 3: ...25 30 40 Diameter cm 10 16 10 16 10 16 Autonomy h 8 8 8 Chimney draft required Pa 10 10 10 Ash pan capacity Litre 2 5 2 5 2 5 1 3 Regulations Important Before commencing the installation of your new Franco Belge appliance it is recommended that the instructions are read and understood Health and Safety at Work Act 1974 The installation should comply with the Health and Safety at Work Act 1974 and ...

Страница 4: ...for the installation of fuel burning appliances otherwise it must necessary to install a tubing The flue must be in good condition and must provide sufficient draught refer to technical details p 3 The flue must be clean It should be swept to remove soot and dislodge tar deposits The flue must be well insulated If the flue inner wall surfaces are cold a good thermal draw is impossible causing cond...

Страница 5: ...he stove expert advice should be sought either from the supplier or the local building inspector 2 5 Connections to flues There are several ways of connecting the stove to the flue Horizontal lengths of flue must be kept to a minimum and should not be more that 150 mm 6 inches long All flue connections must be well sealed Installation instructions X Forbidden 1 Flue duct 2 Stainless funnel shaped ...

Страница 6: ...tes tray etc 2 9 Soot Doors It will be necessary to have a soot door to enable the chimney to be swept This may either be in the actual brickwork of the chimney or in the register plate Various type and positions of soot doors are shown in figure 3 2 10 Commissioning On completion of the installation and after allowing a suitable period of time for the fire cement and mortar to dry out the stove s...

Страница 7: ...y avoided if when lighting your stove from cold the chimney is heated up as quickly possible This will create an up draught which is required to pull air through the stove which in turn burns the fuel The easiest way to produce this column of air moving is to open the air inlet wheel on maxi use paper or fire lighters and small pieces of wood in order to achieve a fast burning fire with little smo...

Страница 8: ...environment pollution and smell etc and cause the fire to burn too quickly and overheat F Green wood and recovered wood can even tually cause a chimney fire 3 4 Maintenance Daily Shake the grate Empty the Ash Pan Do not allow ash to build up under the grate when burning solid fuel as this will cause overheating and damage to the grate Periodically Clean out the flue ways Sweep the chimney at least...

Страница 9: ... continuously burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression In houses equipped with mechanical ventilation partly open a window until the fire is well established Smokes while burning Draught is insufficient þ Consult a chimney specialist Check that the flue is no...

Страница 10: ...D G 01 22 300459 79 Base B E H 01 23 301032 EF Frame C F I 01 23 301032 77 Frame A D G 01 23 301032 79 Frame B E H 01 24 301511 EF Door lock C F I 01 24 301511 77 Door lock A D G 01 24 301511 79 Door lock B E H 01 25 301740 EF Air damper C F I 01 25 301740 77 Air damper A D G 01 25 301740 79 Air damper B E H 01 26 301921 Oscillating grate A B C D E F G H I 01 27 302145 59 Top plate A B C D E F G H...

Страница 11: ... I 02 49 216116 Circulation duct D E F 01 49 216117 Circulation duct G H I 01 53 276001 Plate A B C D E F G H I 01 54 979900 Fixing plate A B C D E F G H I 07 60 162042 Descriptive plate A B C 01 60 162043 Descriptive plate D E F 01 60 162044 Descriptive plate G H I 01 70 181613 Rope A B C D E F G H I 0 9 m Spare parts Continental La Parisienne ref 124 03 01 124 05 01 124 07 01 Technical manual 28...

Страница 12: ...resulting from the use of fuel not recommended in our instructions Parts which are damaged by external causes such as unadapted chimneys thunderstorms damp faulty pressure or fail in pressure thermic anomalies explosions etc Electrical parts which are deteriorated by any connection or use on a supply circuit with voltage within 10 of the indicted voltage 230 V in EU Material subject to modificatio...

Отзывы: