Continental Instruments CICP1800T Скачать руководство пользователя страница 2

A standard on-board power supply provides 800mA @5VDC 
or  500mA  @12VDC  for  reader  power.  An  additional 
3A@12VDC  is  available  with  the  optional  expanded  power 
supply. The Turbo  Superterm  can  be  ordered  with  a  factory 
installed expanded power supply. The expanded power supply 
can  also  be  ordered  separately  and  field  installed  within  the 
Turbo  Superterm  enclosure.  The  expanded  power  supply 
includes a 12AH standby battery, an upgrade to the standard 
7AH battery. The standard 7AH and expanded 12AH batteries 
provide  4–6  hours  standby.  In  addition  to  the  rechargeable 
standby  battery,  each  Turbo  Superterm  includes  a  lithium 
battery for up to one year of data protection.

UL294 (Access Control System Unit), UL1076 (Proprietary 
Burglar Alarm Unit) listings and CE are optional with the 
Turbo Superterm-8.

Typical Door Configuration

See Continental Instruments Configuration Guide for 
additional detailed system wiring information.

Continental Instruments, A Napco Security Group Company 

 355 Bayview Ave., Amityville, NY 11701

(631) 842-9400 

 FAX (631) 842-9135 www.cicaccess.com GSA GS-07F-00039H

CardAccess® and CI SQL 3000™ are trademarks of Continental/NAPCO. © Continental Instruments/NAPCO, 2003.

CICP1800T Eight-Door Intelligent Controller

Continental  Instrument’s  Controllers  can  connect  to  the
CardAccess  Server  via  hardwire  (shown  below),  LAN/WAN 
dial-up modem or fiber optics. See the CIC Configuration Guide 
for additional detailed system information.

Turbo Superterm-8 Components

QTY.

Part No.

Description

1

CICP1800T

or

CICP1800TEXP

Eight (8) reader controller with stan-
dard 40,000 card capacity, 24  
supervised alarm inputs, tamper 
alarm, and 17 relay outputs. Unit ships 
complete in a locked steel enclosure 
including a 7AH standby battery for 
memory and system operation.

Same as above, with expanded 
power supply. Required if more  
than one Relay Expander Board 
(CICP1800TRB) is used or additional 
12VDC is needed. A 12AH Battery is 
included.

1

Standard

14VAC Power Supply via step-
down transformer mounted inside  
enclosure. 10’ power line cable with 
110VAC plug is  included.

1

Standard

7AH Battery Backup included.

1 Optional CICEXPPWS

12V Linear Expanded Power
Supply provides 3A @ 12VDC  
Auxiliary Power. 12AH Battery is 
included.

2 Optional CICP1800MB2X2

Memory Board - 2MB per memory 
board (up to 210,000 cards w/4 MB of 
memory expansion).

Up to 3 
Optional*

CICP1800RB

Relay Expander Board - 16 output 
relays, 8 alarm inputs (Unsupervised).

Up to 3 
Optional*

CICP1800AB

Alarm Expander Board - 16 alarm 
inputs (Supervised). UL Listed.

Note: *A maximum of 3 Expansion Boards in any combination may be added to the Turbo Super-
term enclosure.

A480

Superterm8.5x11x.indd

3/4/04, 2:34 PM

2