CEM-PA-B Function Parameter layout
Ref Page
Command
Parameter Help / Description
STD
EXP
9
LG
EN EN English
X
X
9
MODE
EXP Standard / Expert mode
X
X
9
SENS
AUTO Malfunction monitoring [ON / OFF /AUTO]
X
X
10
EOUT
0 Output signal if not ready [0.01%]
X
10
SYS_RANGE
100 System pressure [bar]
X
X
10
SIGNAL:X
U0-10 Type of Input
X
X
13
N_RANGE:X
100 Sensor nominal pressure [bar]
X
X
13
OFFSET:X
0 Sensor offset [mbar]
X
X
10
SIGNAL:W
U0-10 Type of Input
X
X
14
RA:UP
100 Command signal ramp time [ms]
X
X
14
RA:DOWN
100 Command signal ramp time [ms]
X
X
15
C:P
50 P gain [x 0.01]
x
X
15
C:I
4000 I gain [0.01ms]
X
X
15
C:D
0 D gain [0.1ms]
X
X
15
C:D_T1
500 D gain filter [0.1ms]
x
X
15
C:FF
8000 Feed forward [0.01%]
X
X
16
C:I_LIM
2500 Integrator limitation [0.01%]
X
X
16
C:I_ACT
2500 Integrator activation threshold [0.01%]
X
X
17
MIN
0 Deadband compensation [0.01%]
X
X
17
MAX
10000 Output Scaling [0.01%]
X
X
17
TRIGGER
200 Trigger point of the MIN function in 0.01%
X
X
18
SIGNAL:U
+ Output polarity
X
X
18
CURRENT
1000 Rated solenoid current [mA]
X
X
18
DFREQ
121 Dither frequency [Hz]
X
X
18
DAMPL
500 Dither amplitude [0.01%]
X
X
19
PWM
2604 PWM frequency [Hz]
X
X
19
ACC
ON Auto Adjustment of the current loop [OFF / ON]
X
20
PPWM
7 P-Gain of the current loop
X
20
IPWM
40 I-Gain of the current loop
X
MODE