background image

1

W415-0872 / B / 12.02.10

1.30

SAFETY INFORMATION

!

WARNING

If the information in these instructions is not followed exactly, a 

fi re or explosion may result causing property damage, personal 

injury or death. Improper installation, adjustment, alteration, 

service or maintenance can cause injury or property damage, 

bodily injury or even death. Please  read entire manual before 

you install and use your appliance. 

This appliance has not been tested with an unvented gas log 
set. To reduce risk of fi re or injury, do not install an unvented 

gas log set into the appliance.

-  This appliance can be very hot when burning. 
-  Combustible materials such as fi rewood, wet clothing, etc. placed too 

close can catch fi re. 

- Children and pets must be kept from touching the appliance when it is hot. 
- The chimney must be sound and free of cracks. Before installing this unit, 

contact the local    building or fi re authority and follow their guidelines.

- Operate only with the door tightly closed. 
- Burn wood behind the log retainer directly on the fi rebricks. 
- Do not use an elevated grate or otherwise raise the fi re. 
- At least 14 square inches of outside air must be admitted to the room or 

directly to the unit through a 4” diameter pipe.

- This appliance is designed to burn natural wood only. Higher effi ciencies 

and lower emissions generally result when burning air dried seasoned 
hardwoods, as compared to softwoods or to green or freshly cut 
hardwoods. 

- Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, 

etc. 

- Do not burn treated wood, coal, charcoal, colored paper, cardboard, 

solvents or garbage. 

- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to 

achieve heat output rates that exceed design specifi cations can result in 
steel distortion and damage.

INSTALLER:  LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER:  RETAIN THIS MANUAL FOR FUTURE REFERENCE.

INSTALLATION AND 

OPERATING INSTRUCTIONS

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 

103 Miller Drive, Crittenden, Kentucky, USA, 41030

Phone (705)721-1212 • Fax (705)722-6031 • www.continentalfi replaces.com • ask@continentalfi re.on.ca

$10.00

CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY 

(D.E.Q.) PARTICULATE EMISSION STANDARDS BY E.E.M.C  THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STAN-

DARDS: CSA B366.2, ULC S627, UL 1482.

CI-1402

WOOD INSERT

Содержание CI-1402

Страница 1: ...e admitted to the room or directly to the unit through a 4 diameter pipe This appliance is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air...

Страница 2: ...ISHING 13 5 1 BRICKS AND BAFFLES INSTALLATION 13 5 2 DOOR REMOVAL INSTALLATION 14 5 3 DOOR HANDLE INSTALLATION 14 5 4 FLASHING INSTALLATION 15 6 0 OPERATION 16 6 1 BLOWER 17 6 2 AIR CONTROL 18 6 3 FIR...

Страница 3: ...1 0 INSTALLATION OVERVIEW Rating plate see RATING PLATE INFORMATION section Blower see BLOWER INSTALLATION section Door see DOOR AND HANDLE INSTALLATION section Flashing see FLASHING section Draft se...

Страница 4: ...r servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe servicing a seperate...

Страница 5: ...S APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET TO REDUCE RISK OF FIRE OR PREVENT INJURY DO NOT INSTALL A VENTED OR UNVENTED GAS LOG SET INTO THE APPLIANCE BURNING YOUR UNIT WI...

Страница 6: ...exhaust products to easily flow through it Chimney vent systems that are too short or too long can also have an adverse affect on the flow of exhaust through it The wood burning appliance and chimney...

Страница 7: ...rced air heating devices or a bathroom exhaust fan Expansion contraction noises during heating up and cooling down cycles are normal and to be expected After extended periods of non operation such as...

Страница 8: ...E HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT 111KT A MINIMUM CLEARANCE OF 18 457mm TO THE CHIMNEY CONNECTOR MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION RENSEIGNEZ VOUS AUPR S DESAUTORI...

Страница 9: ...e more than 1 to the side of the insert or between the mantel and the top of the insert SIDEWALL COMBUSTIBLE MANTEL NON COMBUSTIBLE FACING A F G E C B D NON COMBUSTIBLE HEARTH AND THERMAL FLOOR PROTEC...

Страница 10: ...E SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRE STRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUS...

Страница 11: ...ver in position as high as possible with two masonry screws per side through the flanges into the fireplace In Canada Install a listed 6 inch diameter flexible stainless steel liner from the top of th...

Страница 12: ...ements supersede any pre existing facing material clearances listed for the factory built fireplace C Installation must include a full height listed chimney liner meeting HT requirements 2100 F as re...

Страница 13: ...nifold Ensure that the top baffles are pushed all the way to the rear of the firebox leaving a minimum of a 1 gap along the front This will allow the flue gases to escape the firebox C Install the bot...

Страница 14: ...per rod below the door 5 3 DOOR HANDLE INSTALLATION BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE DO NOT STRIKE OR SLAM DOOR N...

Страница 15: ...10 5 4 FLASHING INSTALLATION The top flashing has been shipped flat To install the flashing rest the bottom against the top of the appliance and secure using the tabs as illustrated below Slide the tr...

Страница 16: ...rmally During the break in period the first 2 or 3 fires create only small hot fires using kindling this will allow the firebrick to cure Do not be alarmed if small hairline cracks develop in the fire...

Страница 17: ...us and 450 degrees Fahrenheit 270 degrees Celsius A surface thermometer will help regulate this Without a appliance thermometer you are working blindly and have no idea of how the appliance is operat...

Страница 18: ...e fully out Inadequate draft may cause back puffing into the room through the appliance and chimney connector points and may cause plugging of the chimney Too much draft may cause an excessive tempera...

Страница 19: ...be ready for burning that fall Dry firewood has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of a likelihood that the wood wil...

Страница 20: ...control on HIGH fully open for long periods of time one or two hours C Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door Has a direct flue connection...

Страница 21: ...eaned at least once a year or as often as necessary Remove fibre baffles and clean above them once a year Replace any broken bricks WARNING TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE APPLIANCE...

Страница 22: ...t local authorities for further informa tion on how to handle a chimney fire After the chimney fire is out clean and inspect the chimney or chimney liner for stress and cracks prior to lighting anothe...

Страница 23: ...EN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION DO NOT STRIKE SLAM OR SCRATCH GLASS DO NO...

Страница 24: ...ng do not open the door until the fire is out and do not operate the appliance again until the glass has been replaced available from your Authorized dealer DO NOT SUBSTITUTE MATERIALS 5 3 HOT GLASS W...

Страница 25: ...wo screws from the outer edge of the side panel s C Push the side panel toward the door and pull away from the insert releasing the panel from the keyed slot D Service or replace the blower s as requi...

Страница 26: ...ILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING COMPONENTS RE...

Страница 27: ...W BLACK DOOR EARLY AMERICAN 22 H222 GW GOLD DOOR EARLY AMERICAN 22 H222 SSW BRUSHED STAINLESS STEEL DOOR EARLY AMERICAN 23 CISK CAST IRON SURROUND KIT PAINTED BLACK 24 CISK A CAST IRON SURROUND KIT E...

Страница 28: ...kage Inspect chimney Smokes when door is open Cold air blockage Burn a piece of paper to establish a draft Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are pos...

Страница 29: ...ust fans furnaces clothes dryers etc Any damages to appliance combustion chamber heat exchanger plated trim or other component due to water weather damage long periods of dampness condensation damagin...

Страница 30: ...30 W415 0872 B 12 02 10 43 1 11 0 SERVICE HISTORY...

Страница 31: ...31 W415 0872 B 12 02 10 44 1 12 0 NOTES...

Страница 32: ...32 W415 0872 B 12 02 10 44 1...