background image

2

W415-0318 / 03.05.09

TABLE OF CONTENTS

1.0 INTRODUCTION 

3

1.1 WARRANTY 

4

1.2 DIMENSIONS 

5

1.3 GENERAL 

INSTRUCTIONS 

6

1.4 GENERAL 

INFORMATION 

7

1.5 

CARE OF GLASS 

7

1.6 

CARE OF PLATED PARTS 

7

2.0 INSTALLATION 

8

2.1 

INSERT VENT CONNECTION 

8

2.2 CHIMNEY 

CONNECTION 

8

2.3 GAS 

INSTALLATION 

10

2.4 

WALL SWITCH / THERMOSTAT 

10

2.5 OPTIONAL 

ACCESSORY 

REQUIREMENTS 

10

3.0 FINISHING 

11

3.1 

ALUMINUM EXTRUSION TRIM KIT INSTALLATION 

11

3.2 LOG 

PLACEMENT 

12

3.3 GLOWING 

EMBERS 

13

3.4 DOOR 

INSTALLATION 

13

3.5 

MINIMUM MANTEL CLEARANCE 

14

4.0 OPERATION 

 

15

4.1 

REAR BURNER CONTROL 

16

5.0 MAINTENANCE 

16

6.0 

REPLACEMENT BLOWER INSTALLATION 

16

7.0 ADJUSTMENTS 

17

7.1 VENT 

RESTRICTION 

17

7.2 PILOT 

BURNER 

ADJUSTMENT 

18

7.3 VENTURI 

ADJUSTMENT 

18

7.4 PRESSURE 

ADJUSTMENT 

19

7.5 FLAME 

ADJUSTMENT 

19

7.6 FLAME 

CHARACTERISTICS 

19

8.0 REPLACEMENTS 

20

9.0 TROUBLE 

SHOOTING 

23

10.0 SERVICE 

HISTORY 

25

11.0 NOTES 

26

NOTE: CHANGES, OTHER THAN EDITORIAL, ARE DENOTED BY A VERTICAL LINE IN THE MARGIN.

Содержание CDI-44N

Страница 1: ...tructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier SAFETY INFORMATION CERTIFIED...

Страница 2: ...NUM EXTRUSION TRIM KIT INSTALLATION 11 3 2 LOG PLACEMENT 12 3 3 GLOWING EMBERS 13 3 4 DOOR INSTALLATION 13 3 5 MINIMUM MANTEL CLEARANCE 14 4 0 OPERATION 15 4 1 REAR BURNER CONTROL 16 5 0 MAINTENANCE 1...

Страница 3: ...ents burners and circulating blower and its passageway in the heater and venting system are kept clean The heater and its venting system should be inspected before use and at least annually by a quali...

Страница 4: ...ers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discoloring caused by excessive heat abrasive and chemical cleaners nor chipping on porcela...

Страница 5: ...AUST 3 5 20 30 21 22 27 52 1 8 42 ALUMINUM TRIM 52 1 8 33 ALUMINUM TRIM 3 SIDED BACKER PLATE FRONT VIEW 4 SIDED BACKER PLATE FRONT VIEW TOP VIEW FIGURE 1 2a FIGURE 1 2b FIGURE 1 2c FIGURE 1 2e FIGURE...

Страница 6: ...disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The fireplace must be isolated from the gas supply piping syst...

Страница 7: ...ace prefabricated or masonry only The minimum fireplace opening size in which the heater is to be installed is HEIGHT 21 inches WIDTH 32 inches DEPTH 16 inches The minimum allowable chimney flue size...

Страница 8: ...chimney cleanouts fit properly The refractory glass doors screen rails screen mesh and log grates may be removed from the fireplace before installing the gas fireplace insert Smoke shelves shields and...

Страница 9: ...and log support are detached by removing the 12 perimeter screws of the back wall and the 3 screws located at the back of the log support Remove the vent connection assembly NOTE The vent connection a...

Страница 10: ...not bent or kinked Check for gas leaks by brushing on a soap and water solution For ease of accessibility an optional remote wall switch or millivolt thermostat may be installed in a convenient locat...

Страница 11: ...If this unit is being installed into an existing wood burning zero clearance fireplace then be aware of this precaution Any circulation air opening may be covered with material but not sealed The inse...

Страница 12: ...NG PIN LOCATING PIN B A C D The rear log should be centred on the log support and rest against the rear wall Log 3 rests against the far left grate post and onto the locating pin on the centre support...

Страница 13: ...Use only certified glowing embers and PHAZERTM logs available from your Continental dealer FIGURE 3 4 1 3 4 1 Insert the tool supplied which is located behind the left side trim into spring loaded do...

Страница 14: ...NIMUM MANTEL CLEARANCE This can vary according to the mantle depth Use the graph to help evaluate the clearance needed FIGURE 3 5b FIGURE 3 5a 0 4 14 3 5 H E I G H T M A N T E L MANTEL DEPTH 13 12 15...

Страница 15: ...off all gas to the fireplace Open windows Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s...

Страница 16: ...ory If ignition takes longer consult yourAuthorized dealer distributor 5 0 7 Check that the door gasketing is not broken or missing Replace if necessary The Continental gas fireplace insert comes stan...

Страница 17: ...Reinstall the fire viewing door 6 0 7 Turn the gas supply and electricity back on Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from coming int...

Страница 18: ...TTING 2 3 LINER SYSTEM FRONT REAR NG 1 8 1 4 LP 1 4 5 8 AIR SHUTTER SETTING This unit is approved for use with a 2 liner for air intake and a 3 liner for exhaust For best performance how ever it is re...

Страница 19: ...ne Check that main burner is operating on HI Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane Check that...

Страница 20: ...age or personal injury This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd WARNING COMPONENTS REF NO PART NO D...

Страница 21: ...FLEX LINER X 3 31 W175 0204 3 COUPLER 32 W010 0888 VENT CONNECTION ASSEMBLY 33 W290 0076 VENT CONNECTION ASSEMBLY GASKET 46ACCESSORIES46 REF NO PART NO DESCRIPTION 37 W690 0001 MILLIVOLT THERMOSTAT 38...

Страница 22: ...22 W415 0318 03 05 09 20 40 43 44 42 1 5 8 7 6 45 22 2 11 3 46 47 12 15 18 16 17 13 14 32 34...

Страница 23: ...n Remote wall switch is grounding Remote wall switch wire is grounding Faulty valve Turn up the pilot flame Replace pilot assembly Clean thermopile connection tot he valve Reconnect Replace thermopile...

Страница 24: ...ctrode tip and the pilot burner To ensure proper electrode location tighten securing nut finger tight plus 1 4 turn Check that the manual valve is turned on Check the pilot orifice for blockage Replac...

Страница 25: ...18 03 05 09 TP SERVICE HISTORY 10 0 SERVICE HISTORY Appliance Service History This heater must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns D...

Страница 26: ...26 W415 0318 03 05 09 TP NOTES 11 0 NOTES...

Страница 27: ...27 W415 0318 03 05 09...

Страница 28: ...28 W415 0318 03 05 09...

Отзывы: