5.2.Service Auto Test Steps
STEPS
Control
Possible Errors
While pushing SW2 button for 5 sec, position knob to
Program 1. Then press Start/Pause button. Machine enters
to service autotest.
F2: All warning leds makes fast blink for 2 sec and then
becomes fix off.
Machine shows the last error saved by machine. When
knob positioned to program 2, control steps starts.
The
Routine to
Enter
Servis
Autotest
Step 2
Dryer check Aquaswitch, if aquaswitch ON go
*Aquaswitch connector is taken out
(Knob
to next step (pump activation), if aquaswitch
LD6
*Aquaswitch connector is short circuit
Position 2) OFF give water tank full error
*Styrofoam is borken or not
Step 3
Service must pour water to pump reservoir and
check whether water is pumped to tank.
(Knob
Pump is on
-
If water is not pumped to water tank;
Position 3)
*Pump connector is taken out
Service must check whether tumble is moving to CW.
Step 4
If not;
(Knob
Motor CCW (Tumble CW)-Motor stops
-
*Motor connector is taken out
Position 4)
*Motor might be locked
*Motor belt might be dislocated
Step 5
Service must check whether tumble is moving to
CCW
(Knob
Motor CW (Tumble CCW) -Motor stops
-
*If tumble is moving to CW again, then motor relay
Position 5)
short circuit CCW
Step 6
Check Compressor NTC if heater NTC
*Compressor NTC connector is taken out or short
(Knob
LD3
Position 6) T=255
LD5
circuit
Step 7
(Knob
Check Door NTC if heater NTC T=255
LD2
*Door NTC connector is taken out or short circuit
Position 7)
LD3
Step 8
Compressor OFF- Motor CCW (Tumble
Service must check power of at the home voltage
(Knob
-
and fan will be controlled manually by technical
CW) OFF- Cooling fan ON
Position 8)
service.
Step 9
Compressor ON- Motor CCW (Tumble CW)
(Knob
-
Service must check power of at the home voltage.
Motor OFF
Position 9)
Step 10
Service puts his hand on the humidity sensor plates
Check conductivity sensor when door is
and software checks sensor data
(Knob
LD2
opened and motor is off
*If sensor data=0, humidity sensor connector is taken
Position 10)
LD5
out
Содержание BANDEAU HP F1
Страница 1: ...SECHE LINGE MANUEL DE SERVICE HP F1 BANDEAU ...
Страница 18: ...HP F1 PANEL CUSTOMER SUPPORT SERVICE MANUAL 6 4 Side Panel 1 Remove 10 screws on side panels ...
Страница 22: ...HP F1 PANEL CUSTOMER SUPPORT SERVICE MANUAL 6 7 Rear Cover 1 Remove all screws shown in the photo ...
Страница 40: ...HP F1 PANEL CUSTOMER SUPPORT SERVICE MANUAL 6 22 Plinth Cover 1 Remove 2 plinth pin on Plinth cover ...
Страница 42: ...HP F1 PANEL CUSTOMER SUPPORT SERVICE MANUAL 6 24 Drum Bearing Wheel 1 Remove wheels as shown in the photo ...
Страница 52: ...HP F1 PANEL CUSTOMER SUPPORT SERVICE MANUAL 7 1 1 Motor Measurements 1 2 3 2 1 3 3 1 2 ...
Страница 54: ...HP F1 PANEL CUSTOMER SUPPORT SERVICE MANUAL 7 2 1 Pump Measurements 2 1 1 ...
Страница 58: ...HP F1 PANEL CUSTOMER SUPPORT SERVICE MANUAL 7 5 1 Compressor Measurements 2 1 3 c r s r c s c s r ...