background image

GEP-6612 

Rev. G  103961 
Ref. I.D.: 16128 

 

 
 
 

 
 
 
 
 
 

 

BDI-FLX

TM

 2W-IS BURST DISC SENSOR SYSTEM 

OPERATOR’S MANUAL 

 
 
 

 

 

 
 
 
 
 

 

 
 
 
 

 
 

 
 
 
 

IMPORTANT 

USER SHOULD READ CAREFULLY AND UNDERSTAND 

THIS MANUAL BEFORE INSTALLING, OPERATING OR 

TESTING THIS UNIT 

 

3160 WEST HEARTLAND DRIVE   LIBERTY, MISSOURI  64068-3385 

PHONE:  (816) 792-1500     FAX:  (816) 792-2277 / 5447 

Содержание BDI-FLX 2W-IS

Страница 1: ...BURST DISC SENSOR SYSTEM OPERATOR S MANUAL IMPORTANT USER SHOULD READ CAREFULLY AND UNDERSTAND THIS MANUAL BEFORE INSTALLING OPERATING OR TESTING THIS UNIT 3160 WEST HEARTLAND DRIVE LIBERTY MISSOURI...

Страница 2: ...E OF CONTENTS I PRODUCT DESCRIPTION 3 II SPECIFICATIONS 4 III HANDLING AND UNPACKING 4 IV STORAGE 5 V INSTALLATION 5 VI MAINTENANCE 9 VII LIMITED WARRANTY 9 VIII DISCLAIMER OF WARRANTIES 9 IX DISCLAIM...

Страница 3: ...DI FLX 2W IS for use in hazardous environments and intrinsically safe applications BDI FLX 2W NIS for direct PLC or discrete input BDI FLX 4W NIS for use as dry contact switch that can be used a wide...

Страница 4: ...C Ta 204 C IECEx IEC Ex Scheme Ex ia IIC T4 Ga Ex ia IIIC T135 C Da IP67 UL cULus Hazloc Refer to UL C US Intrinsic Safety Control Drawing GEP 6615 Mechanical Specifications Housing Material ABS Hous...

Страница 5: ...e required conditions for the specific unit 2 The BDI FLX 2W IS System drops a certain amount of voltage in operation typically about 5 5 V This voltage drop determines how many volts the load e g the...

Страница 6: ...r Requirements 1 2W IS maximum intrinsically safe input parameters Ui 12 V Ii 60 mA Pi 180 mW 2 2W IS equivalent internal parameters Ci 1 11 F Li 0 Associate IS Barrier entity parameters must meet the...

Страница 7: ...the BDI FLX 2W IS System since these barriers typically provide highly restrictive voltage for the hazardous field devices However some Zener barriers can be utilized if both the parameter entity and...

Страница 8: ...el 2W IS Connect the BDI FLX sensor pigtail to the BDI FLX interface cable through the M12 connector After insertion fasten the M12 screw ring to lock the connection 3 Connect Output Cable Terminate t...

Страница 9: ...s are designed with industrial category components and every effort has been made to make the unit as easily serviceable as possible Should there be a problem before or during operation please contact...

Страница 10: ...assemblies and their component parts Customer acknowledges and understands that the provisions of these additional terms and conditions including this paragraph concerning disclaimer of consequential...

Отзывы: