LED Indicators 

The “PWR” LED glows solid green when the switch is properly powered.  To aid in
troubleshooting, each port has two LEDs.  The Port 2 LED labeled “L” glows solid if a  
link exists, flashes to 
show activity and shows 
data rate by color: green 
for 100 Mbps and yellow 
for 10 Mbps.  The LED 
labeled “D” glows solid 
green if full-duplex is on 
or is unlit when that port is 
operating in half-duplex 
mode — but in half-duplex 
operation it will flash if a 
collision occurs.  The other 
port LEDs are unlabeled 
but work the same.

 

 

Power Considerations 

Voltage in the range of 10–36 VDC or 24 VAC ±10% must deliver current commensurate 
with 10-watt power consumption.  The recommended size for solid power conductors is 
16–22 AWG; for stranded conductors, use 16–18 AWG.  Ground is directly connected 
to zero volts and the chassis is isolated from zero volts.  Input connections are reverse-
polarity protected. 

Network Connections 

The switch employs Auto-MDIX technology so that either straight-through or crossover 
cables can be used to connect to network interface adapters or to another hub.

 

 

Mechanical

Отзывы: