Power Options 

 

Power Considerations 

Voltage in the range of 10

–36 VDC or 24 VAC must deliver current commensurate with 

power consumption.  Recommended size for solid power conductors is 16

–22 AWG; for 

stranded conductors, use 16

–18 AWG.  Ground is directly connected to zero volts and 

the chassis is isolated from zero volts.  Input connections are reverse-polarity protected. 

Network Connections 

The switch employs Auto-MDIX technology so that either straight-through or crossover 
cables can be used to connect to network interface adapters or to another hub.  

LED Indicators 

The ―PWR‖ LED glows solid green when the switch is properly powered.  To aid in 
troubleshooting, each port has 

two LEDs.  The Port 2 LED labelled ―L‖ glows solid if a 

link exists, flashes to show activity and shows data rate by colour: green for 100 Mbps 
and yellow for 10 Mbps.  The LED labelled ―D‖ glows solid green if full-duplex is on or 
is unlit when that port is operating in half-duplex mode 

— but in half-duplex operation it 

will flash if a collision occurs.  The other port LEDs are unlabeled but work the same.