8. Appendix
RP-COM(FIT)H, RP-COM(FIT)H-AF
41
Table 8.4. Memory Register List < 2 / 2 >
Register number
Function
Access
Initial
value
Supplement
*REG085 Device
ID
of
opposing
station
R/W
0
0 - 255
Enable through mode only
(255: Broadcasting)
REG086 Command
input
timeout
R/W
3sec Inter-character
monitor
time
REG087 Response
OK
("OK")
R/W
Response
0: No response
1: Response
REG088 Response
error
("E?")
R/W
Response
altogether
11111111B E1 - E8
*REG089 Start
with
receive data
output enabled
R/W
Output
prohibition
0: Output prohibition
1: Output permission
0bit: Binary
1bit: Text
2bit: MAC
3bit: UDP
REG090 Reception
type
R/W
00000011B
Initial value = "Do not receive MAC or UDP"
0: Disabled
1: Enabled
REG091 UDP
port
setting
R/W
Disabled
Only applies when UDP is set as the type of data to receive.
REG092
and above
Minimum
value of UDP
port 1
R/W
6000h
0: With no setup
REG094
and above
Maximum
value of UDP
port 1
R/W
6000h
REG096
and above
Minimum
value of UDP
port 2
R/W
0000h
REG098
and above
Maximum
value of UDP
port 2
R/W
0000h
REG100
and above
Minimum
value of UDP
port 3
R/W
0000h
REG102
and above
Maximum
value of UDP
port 3
R/W
0000h
REG104
and above
Minimum
value of UDP
port 4
R/W
0000h
REG106
and above
Maximum
value of UDP
port 4
R/W
0000h
Note that 5000h - 500Fh are reserved and cannot
be used. If specifying the UDP number during
operation, change the reception type to "do not
receive UDP".
Note : In the "Access" column, "R" indicates read.
Содержание RP-COM(FIT)H
Страница 13: ...1 Before Using the Product 8 RP COM FIT H RP COM FIT H AF ...
Страница 23: ...3 Explanation in Mode of Operation 18 RP COM FIT H RP COM FIT H AF ...
Страница 33: ...4 Installation and Connection 28 RP COM FIT H RP COM FIT H AF ...
Страница 35: ...5 Setup 30 RP COM FIT H RP COM FIT H AF ...
Страница 39: ...6 SNMP Agent Functions 34 RP COM FIT H RP COM FIT H AF ...
Страница 41: ...7 Troubleshooting 36 RP COM FIT H RP COM FIT H AF ...