14
Table 2.2. Installation Environment Requirements
Model
PT-S3000HX Series
Ambient
specificatio
ns
Operating
temperature
*1
0°C~50°C with Air Flow: 0.5 m/s (w/ Standard Temp.
SSD) (w/
Extended Temp.
mSATA)
0°C~40°C with Air Flow: 0.6 m/s (w/ Standard Temp. HDD)
Storage
temperature
-10 - 60
°
C
Humidity
10% - 90%RH (No condensation)
Floating dust
particles
Not to be excessive
Corrosive gases
None
Line-
noise
resistanc
e
Line noise
AC line /
±
2kV
Signal line /
±
1kV (IEC61000-4-4 Level 3, EN61000-4-4 Level 3)
Static
electricity
resistance
Contact discharge /
±
4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2)
Atmospheric discharge /
±
8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level
3)
Vibration
resistance
HDD
mode
Operati
on
JIS C 60068-2-6 : 2010
10~ 50Hz/4.9m/ s
2
(0.5G)
1oct/min, 1 cycle (10-150-10 Hz)
5 cycles X,Y,Z per axis(25 mins/axis)
Non-operation
JIS C 60068-2-6 : 2010
10~ 57Hz/0.15 mm(0-p)
57~ 150Hz/19.6m/s
2
(2G)
1oct/min, 1 cycle (10-150-10 Hz)
5 cycles X,Y,Z per axis (40 mins/axis)
SSD mode
Operati
on
JIS C 60068-2-6 : 2010
10~ 57Hz/0.15mm(0-p)
57~150Hz/19.6m/s
2
(2G)
1oct/min, 1 cycle (10-150-10 Hz)
5 cycles, X,Y,Z per axis (40 mins/axis)
Impact
resistance
HDD
mode
Operati
on
JIS C 60068-2-27 : 2011
98m/s
2
(10G)
11ms
Half Sine
3 times X,Y,Z per axis
SSD mode
Operati
on
JIS C 60068-2-27 : 2011
98m/s
2
(10G)
11ms
Half Sine
3 times X,Y,Z per axis
Grounding
Class D grounding, SG-FG / continuity
*1
: For more details on this, please refer to chapter 3, “Installation Requirements”.
*2
: CS field strength of VGA port is 3V; other I/O ports field strength are 10V.
*3
: If using USB extended cable, please use below 1.8 m USB cable. (RS)
Содержание PT-S3000HX-DC Series
Страница 1: ...1 Panel PC S Series PT S3000HX DC Series User s Manual CONTEC CO LTD ...
Страница 17: ...17 Physical dimensions PT S3000HX Figure 2 2 Physical Dimensions PT S3000HX ...
Страница 48: ...48 Figure 5 8 UEFI setting 2 2 SATA Mode Selection change to Intel RST Premium ...
Страница 49: ...49 Figure 5 9 UEFI setting 3 Figure 5 10 UEFI setting 4 Please set RAID ...
Страница 52: ...52 Press CTRL I Figure 5 15 Legancy setting 4 ...
Страница 70: ...70 Save Exit Load save setup items and exit the setup menu Figure 5 28 Save Exit menu ...
Страница 83: ...83 Disposing the battery Dispose the removed battery properly as instructed by local government ...