Страница 1: ...Industrial Multi Controller MC 310B DC355 User s Manual CONTEC CO LTD...

Страница 2: ...used with the earth terminal 1 The bracket fittings 2 M3 screw Use it for fixing bracket fittings 4 Power connector 1 Contact For power connector 4 SD card holder 1 Rubber feet 4 Serial number label 1...

Страница 3: ...to use a power supply that meets this product s power supply specification Copyright Copyright 2012 CONTEC CO LTD ALL RIGHTS RESERVED No part of this document may be copied or reproduced in any form...

Страница 4: ...ety Precautions 4 Safety Information 4 Handling Precautions 5 Environment 7 Inspection 7 Storage 7 Disposal 7 2 Each Component Function 9 Component Name 9 Component Function 10 1 LAN port 10 2 DVI D 1...

Страница 5: ...Installation 21 Distances between this product and its vicinity 22 Software Setup 22 4 Specification 23 Specification 23 Hardware or Factory Setting 23 Functional Specification 24 Installation Enviro...

Страница 6: ...the PC Features Powerful execution platform supporting fanless operation It is a powerful general purpose execution platform for open source applications equipped with SoC AM3517 that incorporates a...

Страница 7: ...7PS 5P 5m D SUB37P Male Connector Set 5pieses CN5 D37M Terminal Unit Power Supply Screw Terminal Unit M3 x 37P EPD 37A 1 2 Screw Terminal Unit M3 5 x 37P EPD 37 1 General Purpose Terminal M3 x 37P DTP...

Страница 8: ...ilable in several languages Note For product information Contact your retailer if you have any technical question about a CONTEC product or need its price delivery time or estimate information How to...

Страница 9: ...ion of equipment and resources Understand the meanings of these labels to operate the equipment safely DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in dea...

Страница 10: ...store the product in the presence of chemicals Before inserting removing an SD card or plugging unplugging connectors or cables be sure to unplug the power cable Do not modify this product CONTEC wil...

Страница 11: ...than 2 kgf cm Regardless of the foregoing statements CONTEC is not liable for any damages whatsoever including damages for loss of business profits arising out of the use or inability to use this CON...

Страница 12: ...CN3 SD RST 12 24 VDC CN1 L1 L2 L3 POW Storage When storing this product keep it in its original packing form 1 Put the product in the storage bag 2 Wrap it in the packing material then put it in the b...

Страница 13: ...1 Introduction 8 MC 310B DC355...

Страница 14: ...e devices for saving data Do not use during operation in environments with a lot of electromagnetic interference 5 Power supply connector Accepts the power connector Supports AWG 24 18 cables 6 Ground...

Страница 15: ...C Not connected 2 DVI D It is a connector for display connection The screen resolutions supported by this product are 1280 x 720 720p 1024 x 786 XGA 800 x 600 SVGA and 640 x 480 VGA For more informati...

Страница 16: ...Pin No Signal name 1 Vcc 2 DATA 3 DATA 4 GND CAUTION It may cause a trouble in recognizing and operating the device according to the kind of USB hub If you use the USB hub we encourage you to take adv...

Страница 17: ...tal fitting into a space between the metal sheet and the screw CN 2 SW CN 3 SD RS T 12 24 VD C CN 1 L 1 L2 L3 PO W O N 3 4 2 1 CN 2 SW CN 3 SD RS T 12 24 VD C CN 1 L1 L2 L3 PO W O N 3 4 2 1 Tighten th...

Страница 18: ...2 RS 485 communication x 2 ports are provided Use the attached communication connector The applicable cable is AWG28 16 Pin No Signal name Pin No Signal name 1 TXD0 6 TXD1 2 TXD0 7 TXD1 3 RXD0 8 RXD1...

Страница 19: ...sponds to a different signal line bit 7 for RxD bit 8 for CTS bit 9 for TxD and bit 10 for RTS If you wish to use a terminator of other than 100 set the terminator switch OFF and insert an external te...

Страница 20: ...using see Removing the battery in Chapter 4 Figure 2 6 Location of SW1 SW2 12 External extended connector It is a connector for external I O Pin No Signal name Pin No Signal name Pin No Signal name Pi...

Страница 21: ...s product is illustrated in Figure 2 7 Connect the input signals to a device which can be current driven such as a switch or transistor output device This product inputs the ON OFF state of the curren...

Страница 22: ...so be connected to a TTL level input as it uses a low saturated transistor for output The residual voltage low level voltage between the collector and emitter with the output on is 0 5 V or less at an...

Страница 23: ...emperature environment Here we give some examples of analog input connections by using flat cable or shield cable Flat cable connection Connect one wire from the signal source to one ground point for...

Страница 24: ...er of LED lighting on start up 1 After power activation ON POW L1 L2 L3 2 Initialization completion ON POW OFF L1 L2 L3 3 Starts OS ON POW L1 L2 L3 4 Finishes starting OS ON POW Blinking L2 OFF L1 L3...

Страница 25: ...2 Each Component Function 20 MC 310B DC355...

Страница 26: ...ies the power supply specifications for this product 12 24VDC 5 The use of a power supply other than the above may result in product failure or accidents Recommended power IPC ACAP12 04L For more info...

Страница 27: ...ed spaces Installation on the wall or desk Ensure a clearance between this product and surrounding equipment of at least 50mm for the top and bottom and front side Figure 3 2 Distances between this pr...

Страница 28: ...terminal software Set all four pins of the switch to OFF and then turn the power on Connect this product to a PC using a crossover LAN cable and access it using SSH Default LAN settings are shown in t...

Страница 29: ...er of channel 4 channels single ended input Input range Bipolar 5V Max input voltage 15V Resolution 12bit Non Linearity error 1 10LSB Conversion speed 100 sec ch Digital input Input point 4 points Inp...

Страница 30: ...le 4 3 Installation Environment Requirements Item Specification Operating temperature 0 50 C Operating humidity 10 90 RH No condensation Floating dust particles Not to be excessive Corrosive gases Non...

Страница 31: ...d on the back x 1 2 Remove DVI D screws x 2 3 After sliding the upper and lower housings apart from each other about by 1 cm separate them vertically 4 Cut the cable tie with scissors and remove the b...