Contec DAI12-4(USB)GY Скачать руководство пользователя страница 62

6. Connecting with Expansion Accessories

 

 

 

 

DAI12-4(USB)GY 

57

 

How the Stack Connection Locking Device Works 

Locking 

Unlocking 

Push the pawl of the locking device 
with a tool that has a slender tip 
downward from above to open the 
spring for the locking device (the 
groove moves toward you). 

Push the groove of the locking device 
with a tool that has a slender tip in the 
direction of the arrow until the device is 
locked. 

 

 

Figure 6.5.  How the Stack Connection Locking Device Works 

Locking device

Stacking hook

Locking device

Stacking hook

Содержание DAI12-4(USB)GY

Страница 1: ...PC HELPER Isolated Analog Output Module for USB DAI12 4 USB GY User s Guide CONTEC CO LTD...

Страница 2: ...is subject to change without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel fre...

Страница 3: ...oftware and User s Guide this guide Check the contents to make sure that you have everything listed below If you do not have all the items or have any damage contact your distributor or CONTEC group o...

Страница 4: ...formation 6 Operation Precautions 7 FCC PART 15 Class A Notice 9 Environment 10 Inspection 10 Storage 10 2 MODULE NOMENCLATURE 11 3 SETUP 13 CONNECTION OVERALL DIAGRAM 13 SETTING A MODULE ID 14 SETUP...

Страница 5: ...BLESHOOTING 41 TROUBLESHOOTING 41 Q A 42 DIAGNOSTIC PROGRAM 44 VERSION UPGRADE 45 How to Upgrade the Firmware 45 RETURNING TO INITIAL STATE 47 6 CONNECTING WITH EXPANSION ACCESSORIES 53 SETTING A DEVI...

Страница 6: ...20 sec 12 bit 4ch Compatible to USB1 1 USB2 0 and capable to achieve high speed transfer at HighSpeed 480 Mbps The voltage or current output range set voltage 10V 5V 0 10V 0 5V current 0 20mA The ran...

Страница 7: ...utput channels The unique structure for connection by stacking enables easy and compact system configuration Screw less connector plug facilitating wiring and plugging unplugging Wiring and plugging u...

Страница 8: ...ry software and which supplies command of hardware produced by our company in the form of standard Win32 API function DLL Using programming languages supporting Win32API functions such as Visual Basic...

Страница 9: ...GY AC adapter input 90 264VAC output 5VDC 2 0A POA200 20 2 AC DC power supply unit input 85 132VAC output 5VDC 3 0A POW AC13GY AC DC power supply unit input 85 264VAC output 5VDC 2 0A POW AD22GY DC D...

Страница 10: ...ery time or estimate information Limited One Year Warranty CONTEC product is warranted by CONTEC CO LTD to be free from defects in material and workmanship for up to one year from the date of purchase...

Страница 11: ...perienced usage misuse or malfunction of this device Use with Safety Please use this product with safety on the basis of understanding following content Notice icon for safety information In order to...

Страница 12: ...off the power for the USB module Please do not touch the module with a wet hand when the power for the module is turned on It is danger of electric shock Be sure to turn off the power for the USB modu...

Страница 13: ...uct loan service to confirm operation before purchasing Regarding CE EMC Directive Notice Please connect the Interface Connector with a shielded cable to meet the mentioned standard above The ferrite...

Страница 14: ...1 Introduction DAI12 4 USB GY 9 FCC PART 15 Class A Notice...

Страница 15: ...product with safety Storage Please store the product according to the state in which you purchased 1 Store the module into a storage bag 2 Store the module into a box with wrapper 3 Please store the...

Страница 16: ...s LED Functions DAI12 4 USB GY Name Function Indicator color LED indicator ON Communication established OFF Communication unestablished ON Operation enabled OFF Operation disabled ON D A conversion er...

Страница 17: ...2 Module Nomenclature 12 DAI12 4 USB GY...

Страница 18: ...overall diagram Please reference to this page for actual connection Figure 3 1 Connection Overall Diagram Software Installation page 15 Connecting to a PC page 17 Connecting to an External Device page...

Страница 19: ...ssigned a unique Module ID in the range of 00 7Fh when several modules with the same model are being connected There are two rotary switches moreover x16 and x1 represent high bits and low bits of Mod...

Страница 20: ...ically If the menu do not start launch X AUTORUN EXE X CD ROM drive from Run in Start menu The screen design may be different Connecting to a PC Installing USB driver Setting Properties Using Device M...

Страница 21: ...ogram in all language in order to use API function Step1 Clicking on Install Development or Execution Environment API USBP WDM Installer dialog box displays Step2 Selecting Advanced Analog I O driver...

Страница 22: ...d of USB hub If you use the USB hub we encourage you to take advantage of the CONTEC s product loan service to confirm operation before purchasing Step1 Setting Supplied CD ROM API USBP WDM The menu s...

Страница 23: ...etect setup information from supplied CD automatically for installing USB driver XXXXXX device name being searched out the name from getting rid of GY from the model Point Please specify the path for...

Страница 24: ...er XXXXX within CONTEC Devices expresses the name from getting rid of GY from the model of USB module In the case of Windows XP 2000 From Start menu click on Settings Control Panel System and then cli...

Страница 25: ...loped by users is running on an other PC please perform foregoing operation on the target computer no need to install software introduced on next page Please use the device name specified in last step...

Страница 26: ...annel 0ch voltage output Channel 0ch current output Analog ground Channel 1ch voltage output Channel 1ch current output Analog ground Not connected Not connected Not connected Not connected Not connec...

Страница 27: ...plug Releasing the orange button after the wire is inserted fixes the cable Compatible wires are AWG 28 20 Removing the connector plug by grasping the cable can break the wire Figure 3 4 Connecting an...

Страница 28: ...ions where the module is at a relatively large distance from the external device or when the noise immunity of the module must be improved In this case the voltage output and the analog ground for eac...

Страница 29: ...wer for the module or the external device is on The maximum current capacity for a voltage output signal is 5mA To avoid any malfunction do not connect an external device that generates a load exceedi...

Страница 30: ...wer supply The use of current output requires an external power supply 17 24V In such a case a power supply with a small ripple should be used in order to avoid an adverse impact on the conversion acc...

Страница 31: ...nt output signal should not be connected to another analog output signal or the output signal of an external device To avoid any malfunction the connector plug should not be attached or detached when...

Страница 32: ...voltage value within the range of 0 10V Because the converted data is based on the value of dividing 10V voltage width voltage span by 4096 the converted data increases every 1 the voltage value incre...

Страница 33: ...he converted data increase every 1 the voltage value increase 4 88mV Moreover the converted data increase every 1 the voltage value increase 2 44mV in case of 5V range Decimal Hexadecimal 10V 4095 FFF...

Страница 34: ...h is inside of module The practicable minimum conversion period is about 400 sec at single channel mode through 1msec at multi channel mode up to 16 channels which is depends on the conversion process...

Страница 35: ...lable and the memory size per channel is up to 64k data at 4 channel use It is able to be D A conversion over 256k data if transferring D A conversion data from host computer before the memory is empt...

Страница 36: ...ansion module Please reference to 6 Connecting with Expansion Accessories Installation method 1 Pushing the fixing hook with a flat head screwdriver renders it into a lock enabled condition this shoul...

Страница 37: ...ule from the upper part of the DIN rail and press the lower part of the unit onto the DIN rail Figure 3 7 Mounting on a DIN Rail 2 3 3 The fixing hook is automatically locked and the module can be mou...

Страница 38: ...to unlock it this operation should be performed on all connected modules Figure 3 8 Removing the Module from the DIN Rail 1 3 2 With the fixing hook unlocked pull the lower part of the unit toward you...

Страница 39: ...e DIN rail Figure 3 8 Removing the Module from the DIN Rail 3 3 Any operation involving the disconnection of modules in a unit in which multiple modules are connected that is attached to a DIN rail sh...

Страница 40: ...gth decreases an ability of peeling strength if once removing a magnet from the enclosure of USB module The example of magneto attachment Notes Please attach in a DIN rail on the wall and use USB Modu...

Страница 41: ...n a desk It should be noted that lateral slit of the module being covered brings about malfunction In addition please use the supplied two rubber feet when setting on a desk or others as figure 3 9 A...

Страница 42: ...ize them when several modules of the same model are being used Factory settings 00 can be used when only one module is connected to one computer Unnecessary to set Module ID Necessary to set Module ID...

Страница 43: ...3 Setup 38 DAI12 4 USB GY...

Страница 44: ...rence is provided in API USBP W32 Help Detailed introduction to search method for help should be found from How to navigate Help in the help For basic usage please reference to Tutorial for help Print...

Страница 45: ...rogram Files CONTEC Sample programs in all language are provided here To run a sample program click on Programs CONTEC API USBP WDM AIO Sample Name from Start menu Distributing Developed Application P...

Страница 46: ...ing with a USB module Follow the following procedure to delete unknown device Start device manager select USB Device and then right click Delete Select Run form Start menu and then type X AUTORUN EXE...

Страница 47: ...tions supporting this form It can not be used by language which do not support corresponding argument type The integrity of the operation cannot be guaranteed because we do not verify the operation Th...

Страница 48: ...4 including the USB module when channels more than this number are wanted please purchase the necessary USB module s and expansion accessories When USB modules are added the USB ports corresponding to...

Страница 49: ...lity exists in hardware or software Run diagnostic program open Properties for USB module of device manager and then click on Diagnosis button in Common Settings tab Using Diagnostic program you can n...

Страница 50: ...ted When using self power remove AC adapter in order to reset status Step2 Set Module ID to FFh Set Module ID to FFh It is special setting for firmware upgrade Point Modules should be performed firmwa...

Страница 51: ...cking Start Upgrade button Upgrade is completed automatically Step7 Setting properties using Device Manager once more After completing upgrade perform settings again by referencing to Setting Properti...

Страница 52: ...uitable for OS used Step1 Uninstalling Driver and the development environment Uninstall procedure for Windows Vista Uninstall of device driver 1 Run Device Manager From My Computer Control Panel selec...

Страница 53: ...e driver software for this device checkbox and then click OK Uninstall of development environment Use My Computer Control Panel Programs and Features to uninstall the development environment Select CO...

Страница 54: ...e driver Select Windows driver package CONTEC and then click Change Remove contains the driver category name caio ccnt cdio csmc etc Uninstall of development environment Use My Computer Control Panel...

Страница 55: ...rX XX development environment and then click Add Remove contains the driver category name AIO CNT DIO etc Uninstall procedure for Windows 98 98SecondEdition Uninstall of device driver Use My Computer...

Страница 56: ...5 Troubleshooting DAI12 4 USB GY 51 Step2 Drawing USB cable from a PC Step3 Restarting USB port...

Страница 57: ...5 Troubleshooting 52 DAI12 4 USB GY...

Страница 58: ...DAI12 4 FIT GY can be connected when adding channels In the case of combination of the USB module DAI12 4 USB GY and three expansion modules DAI12 4 FIT GY it is possible to control 16 channels outpu...

Страница 59: ...ontact Category Model Input Output External dimensions mm DIN rail AC adapter POA200 20 Bundled 90 264VAC 5 0VDC 5 2 0A Max 40 0 W x 105 0 D x 30 0 H exclusive of protrusions No AC DC power POW AD13GY...

Страница 60: ...supply in the following order 1 Remove USB cable 2 Remove external power connector stop power supplying to the USB module Setting a Device ID Set Device ID by rotary switch on the front when adding m...

Страница 61: ...es 56 DAI12 4 USB GY Connection between Modules Stack Connection Locking Devices The module contains connecting locking devices mark two units at the top and bottom Figure 6 4 Stack Connection Locking...

Страница 62: ...tool that has a slender tip downward from above to open the spring for the locking device the groove moves toward you Push the groove of the locking device with a tool that has a slender tip in the d...

Страница 63: ...e Inserting the stack hook by aligning it with the hook insertion inlet for the other device automatically locks the module If a stack connector protective cover is attached the connection operation s...

Страница 64: ...Connecting with Expansion Accessories DAI12 4 USB GY 59 Removing the Module Unlock the locking device at the top and the bottom Remove the connected module from the hook Figure 6 7 Removing the Modul...

Страница 65: ...6 Connecting with Expansion Accessories 60 DAI12 4 USB GY...

Страница 66: ...ns Weight of the module itself 100g Module installation method One touch connection to 35mm DIN rails standard connection mechanism provided in the system Expansion module DAI12 4 FIT GY 3 modules Max...

Страница 67: ...ional Home Edition Microsoft Windows Vista Microsoft Windows Server 2008 Microsoft Windows 7 Support language Microsoft Visual C Ver5 0 Ver 6 0 Microsoft Visual C NET2002 2003 Microsoft Visual Basic V...

Страница 68: ...vice ID of the USB module DAI12 4 USB GY is fixed at 0 DC DC Converter Device ID Interface Connector CH0 to CH1 Interface Connector CH2 to CH3 Control Circuit USB Controller Micro Processor USB Connec...

Страница 69: ...output A D conversion start command to each of DAI12 4 USB GY and two DAI12 4 FIT GY 3 Because DAI12 4 USB GY and DAI12 4 FIT GY together compose a double buffer set conversion data in advance before...

Страница 70: ...GY 65 Physical Dimensions Figure 7 3 Physical Dimensions of the USB Module mm 1 2 50 4 3 5 94 1 2 64 7 1 2 1 2 V AG C V AG C AG V C AG C V RUN LINK0 1 2 3 4 5 6 7 9 A BCD E F 8 0 1 2 3 4 5 6 7 9 A BCD...

Страница 71: ...7 Product Specification 66 DAI12 4 USB GY...

Страница 72: ...n Device Identifier order It is only for expansion modules The channel number is decided by the setting Self power Supplying power by using AC adapter is called Self Power Please make use of AC adapte...

Страница 73: ...31 Himesato Nishiyodogawa ku Osaka 555 0025 Japan https www contec com No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD 1225...

Отзывы: