background image

1 Before Using the Product 

 

 

 

CPS-PWD-30AW24-01 

1

 

1.

 

Before Using the Product 

This chapter provides necessary information before using the product. 

 

About the Unit 

This product is an optional power supply unit for the following. 

When using with non-CONTEC equipment, please refer to the maker website for the basic features data 
and guidance of KH series regarding the specification. 

(https://www.cosel.co.jp/en/products/sub01-26.html) 

 

CPS-PWD-30AW24-01 
CONPROSYS Series : CPS-MCS341 Series etc. 

 

Specifications   

Requirement 

Description 

 

Power supply space 
Rated input voltage 

100 to 240VAC, 50 to 60Hz 

Permissible input voltage 

85 to 264VAC, 50 to 60Hz 

Input current 

0.55A typ (115VAC), 0.35A typ (230VAC) 

Rated output voltage 

24VDC 

Rated output current 

1.3A (Max.) 

Isolation 

Input-Output  3000VAC 1minute 50M

 (500VDC) (At room temperature) 

Input-PE 

2000VAC 1minute 50MΩ (500VDC) (At room temperature)

 

Output-PE 

500VAC    1minute 50MΩ(500VDC) (At room temperature)

 

 

Environmental specs 
Temperature 

Operating : -20 to +70°C, non operating : - 30 to + 85°C 

Humidity 

Operating : 20 to 90%RH (No condensation) 
Non operating : 20 to 90%RH (No condensation) 

Floating dust particles 

Not to be excessive 

Corrosive gases 

None 

Vibration resistance 

10 to 55Hz / 2.0G 

 

Construction 
Length of DC cable (mm)  200 (not include connector) 
External dimensions (mm)  22.5(W)×75(D)×90 (H) (not include projection) 
Weight 

Main body : 165g Max. 

Longevity 

7years (temperature 50°C, Input 100VAC, Output 0.9A)   

* The derating is required. Please see chapter 3.Function Description for more details. 

 

 

Содержание CPS-PWD-30AW24-01

Страница 1: ...CONPROSYS 24VDC AC DC Converter CPS PWD 30AW24 01 User s Guide CONTEC CO LTD...

Страница 2: ...e product consists of the items listed below Check with the following list that your package is complete If you find missing or damaged items please contact your retailer Product Configuration list Po...

Страница 3: ...this document is subject to change without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document p...

Страница 4: ...iler if you have any technical questions about a CONTEC product or need its price delivery time or estimate information How to Obtain Service For replacement or repair return the device freight prepai...

Страница 5: ...contact the CONTEC sales representative or sales office To avoid electrocution do not use the product with a wet hand Be sure to connect the product to the stipulated power supply voltage Connecting...

Страница 6: ...e chemicals or a volatile solvent such as benzene and thinner to prevent peeling or discoloration of the paint When transporting the product provide adequate measures to protect it from vibration or s...

Страница 7: ...re Using the Product 1 About the Unit 1 Specifications 1 2 Physical Dimensions and Component Identification 3 Physical Dimensions 3 Interface 3 Assembly Layout 4 3 Function Description 5 The Range of...

Страница 8: ...rrent 0 55A typ 115VAC 0 35A typ 230VAC Rated output voltage 24VDC Rated output current 1 3A Max Isolation Input Output 3000VAC 1minute 50M 500VDC At room temperature Input PE 2000VAC 1minute 50M 500V...

Страница 9: ...1 Before Using the Product 2 CPS PWD 30AW24 01...

Страница 10: ...terface Table 2 1 Interface Power supply unit Type CPS PWD 30AW24 01 Pin Number 1 2 3 4 5 Signal name AC GND 100 240VAC PE 24VDC DC GND Table 2 2 Connector DC cable 6 6 9 3 8 3 10 9 6 6 9 3 60 1 47 5...

Страница 11: ...Component Identification 4 CPS PWD 30AW24 01 Assembly Layout Terminal tightening torque 10KgFcm When you use the our optional AC cable IPC ACCODE3 Figure 2 2 Assembly drawing Red Black Green Black Wh...

Страница 12: ...e range If input value doesn t fall within above range a unit may not operate in accordance with specifi cations and or start hunting or operate protection circuit or fail If you need to apply a squar...

Страница 13: ...gradually When blocking the power use a dial to decrease gradually as well Refrain from conducting a withstand voltage test with a timer since it may drive the excessive apply voltage when the timer o...

Страница 14: ...rail either push down the area marked C or insert a tool such as driver to the area marked D and pull the unit apart from the rail When you couldn t remove the unit easily push down the area marked C...

Страница 15: ...ent temperature as different by input voltage Derating curve is shown below In the hatched area the specification of Ripple Ripple Noise is different from other area Derating Curve Convection Figure 3...

Страница 16: ...3 Function Description CPS PWD 30AW24 01 9 Figure 3 6 Derating curve depend on ambient temperature...

Страница 17: ...3 Function Description 10 CPS PWD 30AW24 01 Expected Lifetime Expected Lifetime Table 3 1 Expected lifetime...

Страница 18: ...electricity and for a while after turning off please don t touch the inside of a power supply because there are some hot parts in that When a mass capacitor is connected with the output terminal load...

Страница 19: ...3 Function Description 12 CPS PWD 30AW24 01...

Страница 20: ...oducts CPS PWD 30AW24 01 13 4 List of Optional Products AC power cable IPC ACCODE3 AC cable with 3 round end terminal Length 2 meters Rating 7A 125V Visit the Contec website regarding information on t...

Страница 21: ...ecification note July 2020 Change signal name for Interface connector CPS PWD 30AW24 01 User s Guide CONTEC CO LTD July 2020 Edition 3 9 31 Himesato Nishiyodogawa ku Osaka 555 0025 Japan https www con...

Отзывы: