Overview

Overview

Overview

Overview

The pulse oxygen saturation is the percentage of HbO

2

in the total Hb in the blood, so-called the O

2

concentration in the blood. It is an important bio-parameter for the respiration. A number of diseases

relating to respiratory system may cause the decrease of SpO

2

in the blood, furthermore, some other

causes such as the malfunction of human body's self-adjustment, damages during surgery, and the

injuries caused by some medical checkup would also lead to the difficulty of oxygen supply in

human body, and the corresponding symptoms would appear as a consequence, such as vertigo,

impotence, vomit etc. Serious symptoms might bring danger to human's life. Therefore, prompt

information of patients' SpO

2

is of great help for the doctor to discover the potential danger, and is of

great importance in the clinical medical field. The Pulse Oximeter features in small volume, low

power consumption, convenient operation and being portable.It is only necessary for patients to put

one of his fingers into a probe for diagnosis, and a display screen will directly show the measured

value of pulse oxygen saturation with the high veracity and repetition.

2

2

2

2.1

.1

.1

.1....

Features

Features

Features

Features

A.

A.

A.

A.

Operation of the product is simple and convenient.

B.

B.

B.

B.

The product is small in volume, light in weight and convenient in carrying.

C.

C.

C.

C.

Low power consumption

2

2

2

2.2

.2

.2

.2....

Major

Major

Major

Major applications

applications

applications

applications and

and

and

and scope

scope

scope

scope of

of

of

of application

application

application

application

The Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through

finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare,

physical care in sports (It can be used before or after doing sports, and it is not recommended to use

the device during the process of having sport) and etc.

The problem of overrating would emerge when the patient is suffering from toxicosis which

caused by carbon monoxide, the device is not recommended to be used under this circumstance.

2

2

2

2.3

.3

.3

.3....

Environment

Environment

Environment

Environment requirements

requirements

requirements

requirements

Storage Environment

a) Temperature :-40

℃~

+60

b) Relative humidity :5%

95%

c) Atmospheric pressure :500hPa

1060hPa

Operating Environment
a) Temperature:10

℃~

40

b) Relative Humidity :3 0%

75%

c) Atmospheric pressure:700hPa

1060hPa

3

3

3

3....

Principle

Principle

Principle

Principle

Principle of the Oximeter is as follows: An experience formula of data process is established taking

use of Lambert Beer Law according to Spectrum Absorption Characteristics of Reductive

Содержание CMS50EW

Страница 1: ...I...

Страница 2: ...sensor sensor sensor sensor should should should should not not not not be be be be applied applied applied applied to to to to the the the the same same same same finger finger finger finger for for...

Страница 3: ...tions 4 4 1 Main performance 4 4 2 Main Parameters 4 5 Installation 5 5 1 View of the front panel 5 5 2 Installing the hanging rope 5 5 3 Accessories 5 6 Operating Guide 6 6 1 Application method 6 6 2...

Страница 4: ...anyard is made of non sensitive material Please do not use lanyard if the user is allergic to lanyard Do not enwind neck with lanyard in order to avoid accident The disposal of scrap instrument and it...

Страница 5: ...is used to adult or infant it depends on the probe selected optional The update period of data is less than 5 seconds which is changeable according to different individual pulse rate Please read the...

Страница 6: ...peration of the product is simple and convenient B B B B The product is small in volume light in weight and convenient in carrying C C C C Low power consumption 2 2 2 2 2 2 2 2 Major Major Major Major...

Страница 7: ...ore working abnormally which is due to low voltage E Automatically power off function when the device is under the state of measuring interface without external probe it will automatically power off w...

Страница 8: ...rement DC 3 6 V 4 2V G G G G Optical Optical Optical Optical Sensor Sensor Sensor Sensor Red light wavelength is 660nm 6 65mW Infrared wavelength is 880nm 6 75mW H H H H Adjustable Adjustable Adjustab...

Страница 9: ...side side side side If If If If the the the the alarm alarm alarm alarm function function function function is is is is on the on the on the on the device device device device will will will will prov...

Страница 10: ...Bluetooth The specific operation methods are as follows Please note in the Settings Menu CLICK CLICK CLICK CLICK short push of button and PRESS PRESS PRESS PRESS prolonged push of power button 1sec Fi...

Страница 11: ...he the Alarm Alarm Alarm Alarm setting setting setting settings s s s Click button to select EXIT then Press button to exit the Alarm Settings Menu C C C C ID ID ID ID setting setting setting setting...

Страница 12: ...u Click button to select EXIT then Press button to exit the Main Menu 6 1 6 6 1 6 6 1 6 6 1 6 PC PC PC PC software software software software operation operation operation operation By PC software the...

Страница 13: ...Please clean and disinfect the device after operating according to the User Manual 7 1 6 6 6 6 3 3 3 3 Clinical Clinical Clinical Clinical restrictions restrictions restrictions restrictions A A A A A...

Страница 14: ...se Pulse Pulse Pulse Rate Rate Rate Rate are are are are not not not not display display display displayed ed ed ed stabl stabl stabl stably y y y 1 The finger is not laid inside deep enough 2 The fin...

Страница 15: ...EE 2002 96 EC 10 10 10 10 Function Function Function Function Specification Specification Specification Specification Information Information Information Information Display Display Display Display Mo...

Страница 16: ...ensity Range Continuous bar graph display the higher display indicate the stronger pulse Battery Battery Battery Battery Requirement Requirement Requirement Requirement Voltage 3 7 rechargeable lithiu...

Страница 17: ...14 Appendix Appendix Appendix Appendix State Alarm condition delay Alarm signal generation delay Low voltage alarm 1s 20ms Spo2 alarm 330ms 20ms Pulse rate alarm 330ms 20ms Probe error alarm 16ms 20ms...

Отзывы: