d)
Data
Data
Data
Data
storage
storage
storage
storage
setting
setting
setting
setting
This instrument has the ability to store 24 hours worth of data.
It can store the measured pulse rate
and SpO
2
value accurately, transfer the data to the computer, display the data and print reports (with
the included SpO
2
Software - Green Heart)
a.
a.
a.
a.
From the “Settings Menu” Click the power button to select “Record”, then Press the power
button to enter the start time of data storage test (see figure 8).
b.
b.
b.
b.
Click the power button to move the underline to the time to be set (hours and minutes), then Press
and hold the power button to adjust the time setting. After setting the time, Click the power button to
move the underline to “Y”, Press the power button to exit the “time setting menu”, and recording will
begin. If you move the underline to “n”, and Press the power
button to quit the “time setting menu”,
the recording will not begin and the data stored in memory will not be deleted.
c.
c.
c.
c.
If the data storage function is being turned on, when return to the measuring interface, a red
"REC"sign and a flashing red dot would appear on screen, which means the device is in a state of
storing
d.
d.
d.
d.
In the state of storing, whatever interface the device is on (measuring interface, menu interface),
the sign "Recording" would appear on the screen in 30 seconds, then the screen will be automatically
shut down. If press the button shortly at this moment, the sign "Recording" would appear on the
screen, and then the screen will be automatically shut down again; if press the button long , the device
would return to the former interface.
e.
e.
e.
e.
If turning on the data storage function, the former data storage will be automatically removed.
f.
f.
f.
f.
In the state of data storing, after the screen is automatically shut down, the pulse sound indication
would be off for saving power.
g.
g.
g.
g.
When the storage space is full, it displays “Memory is full” on the screen, and then shut down in
a few seconds. But it will still display “Memory is full” by the next time you turn on the device on the
purpose of warning the user, if press the button again, it will enter the measuring interface.
Figure 8
e)
U
U
U
U
pload
pload
pload
pload
ing
ing
ing
ing
the
the
the
the
data
data
data
data
to
to
to
to
the
the
the
the
PC
PC
PC
PC
after
after
after
after
recording
recording
recording
recording
a.
a.
a.
a.
Please connect the device with computer by the data line which is affiliated with the device,then
double click"SpO
2
Review"icon to open"SpO
2
Review"program,click the ‘New Session’ Icon in the
software, enter the patient data and then click ‘ok’.
The Software will then display “device
connected, waiting for data”.
b
b
b
b
...
.
At this time , Press the power button to enter the “Settings Menu” and then Click the power
button to select “Upload”. Press the power button to select “on” then the data will be transferred to
your computer.
ccc
c
...
.
In the state of storing, it is not applicable for the users to upload the stored date to computer.
d
d
d
d
. In the state of uploaging, you cannot end it artificially, when the upload of stored data is
finished,the menu choice bar will move to "Exit"automatically.
f)
Exit
Exit
Exit
Exit
the
the
the
the
main
main
main
main
menu
menu
menu
menu
Click the power button to select “EXIT”, then Press the power button to exit the Main Menu.
E.
E
E
E
E
xternal
xternal
xternal
xternal
probe
probe
probe
probe
function
function
function
function
(optional)
(optional)
(optional)
(optional)