Contec AO-1604CI3-PCI Скачать руководство пользователя страница 2

 

Ver.1.02 

  AO-1604CI3-PCI   

  2   

 

Support Software 

 

Windows version of digital I/O driver API-AIO(WDM)   

[Stored on the bundled disk driver library API-PAC(W32)] 

The API-AIO(WDM) is the Windows version driver library software that 

provides products in the form of Win32 API functions (DLL).    Various 

sample programs such as Visual Basic and Visual C++, etc and diagnostic 

program useful for checking operation is provided. 

For more details on the supported OS, applicable language and new 

information, please visit the CONTEC’s Web site. 

Linux version of digital I/O driver API-AIO(LNX)  

[Stored on the bundled disk driver library API-PAC(W32)] 

The API-AIO(LNX) is the Linux version driver software which provides 

device drivers (modules) by shared library and kernel version.    Various 

sample programs of gcc are provided. 

For more details on the supported OS, applicable language and new 

information, please visit the CONTEC’s Web site. 

Data acquisition VI library for LabVIEW    VI-DAQ  

(Available for downloading (free of charge) from the CONTEC web 

site.) 

This is a VI library to use in National Instruments LabVIEW. VI-DAQ is 

created with a function form similar to that of LabVIEW's Data Acquisition 

VI, allowing you to use various devices without complicated settings. 

For more details on the library and download of VI-DAQ, please visit the 

CONTEC’s Web site. 

 

 

Cable & Connector

 

 

Cable (Option) 

Shielded Cable with Two 37-pin D- SUB Connectors 

  : PCB37PS-0.5P (0.5m), PCB37PS-1.5P (1.5m) 

Flat Cable with Two 37-pin D- SUB Connectors 

  : PCB37P-1.5 (1.5m) 

Shielded Cable with One 37-pin D- SUB Connector 

  : PCA37PS-0.5P (0.5m), PCA37PS-1.5P (1.5m) 

Flat Cable with One 37-pin D- SUB Connector 

  : PCA37P-1.5 (1.5m) 

 

 

Accessories

 

 

Accessories (Option) 

Screw Terminal (M3 x 37P) 

 

: EPD-37A *1*2 

Screw Terminal (M3.5 x 37P)   

: EPD-37 *1 

General Purpose Terminal (M3 x 37P) 

: DTP-3C *1 

Screw Terminal (M2.5 x 37P) 

: DTP-4C *1 

*1  PCB37PS -*P optional cable is required separately (0.5m is recommended.). 
*2  "Spring-up" type terminal is used to prevent terminal screws from falling off. 

 

 

Packing List 

 

Board [AO-1604CI3-PCI] …1 
First step guide … 1 
Disk *1 [API-PAC(W32)] …1 
Warranty Certificate …1 
Serial number label …1 

 

*1   The bundled disk contains the driver software and User’s Guide 

 

 

 

 

Connector Pin Assignment

 

 

 

Voltage Output 0 
  - Voltage Output3 

Analog voltage output signal. 
The numbers correspond to channel numbers. 

Current Output 0 
  - Current Output 3 

Analog current output signal.     
The numbers correspond to channel numbers. 

Analog Ground 0 
  - Analog Ground 3 

Analog grounds for identically numbered output signals. 

External Trigger Input 

External trigger input signal 

External Sampling Clock 
Input 

External sampling clock input signal. 

Timer Output 

Output signal of programmable timer 

Settling Busy Output 

Output signal indicating that the board is performing DA conversion. 

Plus Common 

Connect the plus side of external device.     
Common for each "External Trigger Input", "External Sampling Clock Input", "Timer 
Out", "Settling Busy Output" signal. 

Minus Common 

Connect the minus side of external device. 
Common for each "Timer Out", "Settling Busy Output" signal. 

N.C. 

No connection to this pin. 

 

CAUTION 

 

Do not connect any of the outputs and power outputs to the analog or digital ground.     
Neither connect outputs to each other.    Doing either can result in a fault. 

 

 

Analog Output Signal Connection 

 

The sections below describe how to connect the signals using flat cable 

and shielded cable. 

Connecting example of voltage output 

The following figure shows an example of optional flat cable (PCA37P) 

connection. Connect the CN1 analog output channels and ground to the 

external device's input and ground. 

Connection of voltage output (Flat Cable) 

 

The following example connects a signal source to the board using a 

shielded cable.    Use shielded cable if the distance between the board 

and loading is long or if you want to provide better protection from 

noise.  Use the core of the shielded cable to connect the analog output 

of CN1 to the input of the external device and use the shield braid to 

connect the CN1's analog ground to the external device's ground. 

Analog Output Connection (Shield Cable) 

 

CAUTION 

If the board and the target receive noise or the distance between the board and the signal source is too long, 
data may not be input properly. 

The maximum output current-carrying capacity of the analog output signal is ±5 mA.    Check the 
specifications of the target before connecting the board to it. 

CN1

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Settling Busy Output

Timer Output

Minus Common

N.C.

N.C.

Analog Ground 3

N.C.

N.C.

N.C.

Analog Ground 2

N.C.

N.C.

N.C.

Analog Ground 1

N.C.

N.C.

N.C.

Analog Ground 0

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

Plus Common

External Trigger Input

External Sampling Clock Input

N.C.

N.C.

Current Output 3

Voltage Output 3

N.C.

N.C.

Current Output 2

Voltage Output 2

N.C.

N.C.

Current Output 1

Voltage Output 1

N.C.

N.C.

Current Output 0

Voltage Outpu 0

Voltage Output 0...3

Analog Ground 0...3

Target

BOARD

Cable

CN1

Digital Multi-Meter etc.

MOSFET Relay

+

-

CN1

Target

Coaxial cable

Voltage Output 0...3

Analog Ground 0...3

BOARD

MOSFET Relay

Digital Multi-Meter etc.

+

-