Contec AIO-121602AL-PCI Скачать руководство пользователя страница 5

 

 

Ver.1.02

 

 AIO-121602AL-PCI 

 

 

5

 

CAUTION

 

If the board or the connected wire receives noise, or the 
distance between the board and the target is long, data may 
not be outputted properly. 
For analog output signal, the current capacity is ±3mA (Max.).   
Check the specification of the connected device before 
connecting the board. 
Do not short the analog output signal to analog ground, 
digital ground, and/or power line.    Doing so may damage 
the board. 
Do not connect an analog output signal to any other analog 
output, either on the board or on an external device, as this 
may cause a fault on the board. 

 

 
 

The following sections show examples of how to connect digital 
I/O signals, counter I/O signals, and other control I/O signals 
(external trigger input signals, sampling clock input signals, 
etc.).

  

All the digital I/O signals and control signals are TTL 

level signals. 

Digital Input Connection 

10k

Ω

Digital Input

Digital Ground

BOARD

CN2

Cable

Target

 

Digital Output Connection 

Digital Ground

BOARD

CN2

Cable

Target

Digital Output

I

OL

=24mA

 

CAUTION

 

Do not short the output signals to analog ground, digital 
ground, and/or power line.

   

Doing so may damage the board. 

About the counter input control signal 

Counter Gate Control Input (refer to the page 3 Connector Pin 
Assignment) acts as an input that validate or invalidate the 
input of an external clock for the counter.    This function 
enables the control of an external clock input for the counter.   
The external clock for the counter is effective when input is 
"High", and invalid when input is "Low".    If unconnected, it is a 
pull-up in the board (card) and remains "High". Therefore the 
external clock for the counter is effective when the counter gate 
control input is not connected. 

CAUTION

 

Do not short the output signals to analog ground, digital 
ground, and/or power line.    Doing so may cause damage. 

Digital I/O signals, Counter signals and 
Control

 

signals Connection 

 

 