Contec AD12-64(PCI) Скачать руководство пользователя страница 2

Ver.3.00

AD12-64(PCI)

2

Specification

Item 

AD12-64(PCI) 

 Analog input  

  

  

  

 Number of input  

  

 channels 

 
 

64 single -ended input channels or 32 differential input channels   
(specified by software) 

  

 Input range 

 Non-insulated bipolar ±10V, ±5V, ±2.5V, ±1.25V  

  

  

 or Non-insulated unipo lar 0~10V, 0~5V, 0~2.5V, 0~1.25V  

  

  

 (specifiable by software for each channel) 

 

 

  

 Maximum input voltage 

 ±15V 

 

 

   Input impedance  1 M Ohm  or higher   
  

 Resolution 

 12bit 

 

 

  

 Non-1inear error  *1 

 ±2LSB (±10V, ±5V, 0~10V. 0~5V range) 

 

 

     ±4LSB (±2.5V, ±1.25V, 0~2.5V range)   

  

  

 ±8LSB (0~1.25V range) 

 

 

  

 Conversion rate 

 10µsec/ch at Max. 

 

 

  

 Conversion start trigger 

 Software/sampling clock 

 

 

  

 

 
Sampling clock 

 

Internal sampling clock : 10,000~1,073,741,824,000nsec  
(specified in steps of 250nsec) 

  

  

 External sampling clock : TTL-level falling edge  

 Digital input/output  

  

 

 

   Number of output points  Non-insulated 4 output points (TTL-level active high) 
  

 Number of input points 

 Non-insulated 4 input points (TTL-level active high) 

 Programmable timer 

  

 

 

  

 Specifiable cycles  

 500~1,073,741,824,000nsec (specifiable in steps of 250nsec)  

  

 Status  

 Count -up, count -up overrun  

 

 

  

 Timer output signal 

 TTL -level 250nesc low pulse, low output current I

O L

 = 24mA 

 External trigger input  

  

 

 

  

 External trigger input signal    Non-insulated one point input (TTL-level rising edge)  

 

 

 Status  

 Trigger input, trigger input overrun 

 

 

 Interrupt 

  

 

 

  

 Interrupt level 

 1point 

 

 

 

 

 Interrupt source  

 8types 

 

 

 Interface connector  

  

 

 

  

 CN1 

 

PCR-E96LMD (product of HONDA TUSUSHIN KOGYO Co.,   
LTD.) or equivalent 

 General  

  

 

 

  

 I/O addresses  

 32ports occupied 

 

 

  

 Operating c onditions 

 0~50°C, 20~90% (No condensation) 

 

 

  

 Current consumption *2 

 DC+5V  700mA (Max.) 

 

 

  

 Dimensions (mm) 

 176.4(L) x 107.0(H)  

 

 

  

 Weight 

 150g  

 

 

  

  

  

 

 

*1   

  

 

The nonlinearity error can be 0.1% of the maximum range at an ambient temperature of  0 or 
50°C Celsius.  The error can  be minimized by calibrating the board at the temperature equalto 
the temperature of the operating environment. 

*2 
 

 

2 Current consumption increases if power (+5V) is supplied to an external device from 
connector.  

 

176.4

1

0

7

.0

[mm]

 Board size

Содержание AD12-64(PCI)

Страница 1: ...et up by software 10V 5V 2 5V 1 25V 0 10V 0 5V 0 2 5V 0 1 25V Input range setup by software A sampling to the arbitrary timing by software or the periodic sampling which synchronized with the sampling...

Страница 2: ...4 input points TTL level active high Programmable timer Specifiable cycles 500 1 073 741 824 000nsec specifiable in steps of 250nsec Status Count up count up overrun Timer output signal TTL level 250...

Страница 3: ...driver and download service http www contec co jp apipac of difference file are also offered Optional Support Software Collection for measurement systems development of ActiveX components ACX PAC W32...

Страница 4: ...nd Ana log I nput 47 23 A na log In put 39 23 Ana log I nput 46 22 A na log In put 38 22 Ana log I nput 45 21 A na log In put 37 21 Ana log I nput 44 20 A na log In put 36 20 An alog G r ou nd An alog...

Страница 5: ...og I nput14 6 Ana log Input 6 6 An alog I nput13 5 Ana log Input 5 5 An alog I nput12 4 Ana log Input 4 4 Ana log Gr ou nd Ana log Gr ou nd 5V D C fr om P C 5V D C fr om P C Sa mpling Busy Tim er O ut...

Страница 6: ...ch is not connected to the source of a signal Differential input mode It is an example of connection when using a flat cable input of each analog input channel of CN1 is connected to a signal and inpu...

Страница 7: ...ng the Control Signal Inputs D igita l Gr ound Tar get Cable CN1 Input 10k BOARD ALS540 or equivalent Connecting the Control Signal Outputs Digita l Gr ound Tar get Cable CN1 Output IOL 24mA BO ARD AL...

Отзывы: