6
Current
1A
2A
3A
4A
5A
6A
7A
8A
9A
10A
Cable Type
Cable Length
Maximum
Cable
Length
Round
Cable
(CSA)
1mm
2
1319m
659m 440m 330m 264m 220m 188m 165m 147m
132m
1.5mm
2
1547m
773m
516m
387m
309m 258m 221m
193m
172m
155m
2.5mm
2
1739m
870m 580m 435m 348m 290m 248m 217m
193m
174m
Flat
Cable
(Width)
10mm
979m
489m 326m 245m 196m
163m
140m 122m
109m 98m
12.5mm
1851m
925m 617m
463m 370m 308m 264m 231m
206m 185m
25mm
2450m 1225m 817m
613m
490m 408m 350m 306m 272m 245m
Double-Turn Loop
Single-Turn Loop
The tables in this section show the metric maximum cable lengths for
different maximum required currents.
No clipping below 1.6kHz (IEC specifications):
Example:
If an installed cable is
520m of 25mm flat single turn
and the
required current noted in Step 3 (7) of Set-Up (see page 14) is
5
amps or greater, the driver is clipping.
Suitable Cable Lengths (Metric)
Current
1A
2A
3A
4A
5A
6A
7A
8A
9A
10A
Cable Type
Cable Length
Maximum
Cable
Length
Round
Cable
(CSA)
1mm
2
959m
479m 320m 240m 192m
160m 137m
120m 107m
96m
1.5mm
2
1036m 518m
345m 259m 207m 173m
148m 130m
115m
104m
2.5mm
2
1089m 544m 363m 272m
218m
181m
156m 136m
121m
109m
Flat
Cable
(Width)
10mm
856m
428m 285m 214m
171m
143m
122m
107m
95m
86m
12.5mm
1324m
662m 441m
331m
265m 221m
189m
166m 147m
132m
25mm
1568m 784m 523m 392m
314m
261m
224m 196m 174m
157m
The tables in this section show the metric maximum cable lengths for
different maximum required currents.
No clipping below 1.6kHz (IEC specifications):
Example:
If an installed cable is
166m of 1.5mm² (round) single turn
and
the required current noted in Step 3 (7) of Set-Up (see page 14)
is
4 amps or greater,
the below table indicates that
the driver
is clipping
. If the required current noted in Step 3 (7) is
less
than 4 amps, the driver is not clipping
.