4
8. Warnings
6. Self Diagnostic
The controller is equipped with a self diagnostic software that will check functionality of all main components. If
there is a fault with any part of the controller or controller is operating outside of the temperature limits, the display
will show ‘Err’ on the display. If this happens, controller will not function in order to protect itself and the heaters.
Do NOT handle the appliance with wet hands.
Do NOT use the appliance in workshops or rooms where excessive dust is generated or present.
Ensure that nothing is pushed into any aperture of this controller.
Do NOT cover or restrict any aperture Do NOT use the appliance if damaged.
Do NOT leave the appliance unattended where young children are present.
If used in a bathroom, the heater is to be installed so that it cannot be touched by a person in the bath or
shower.
Operating temperature range -10 to +40ºC.
7. Pairing with heaters
In order to pair your appliance with the controller:
Turn power to the appliance ON.
Within 20 seconds, press and hold the ON button on the controller until the display shows ‘PAIR’.
After the pairing is finished, the display shows ‘TEST’.
If the pairing was successful, the appliance should emit heat. It can take up to 5 seconds.
Press the button to exit pairing and return to default OFF state.