Consort PLE050MWIFI Скачать руководство пользователя страница 7

 

66001142 Iss 01 

16. Control using the Consort Connect app 

Basic control of an individual heater 

When you open the Consort Connect app, select the 
heater you would like to control. This will bring you to the 
main page for controlling the heater. In this page, you 
can change the operating mode and comfort tempera-
ture on this screen. The dial in the middle of the screen is 
used to adjust the temperature. The icons on the top of 
the screen are used to change the operating mode. 

 

In the settings menu, select the title ‘basic’ to access the 

basic menu. In this menu, you can view the wattage of 
the heater, adjust the temperature correction and tog-
gle open window detection, the occupancy sensor and 
self learning mode on/off.  The occupancy sensor and 
self learning mode are for MWIFI models only.

 

17. Basic settings menu 

18. Pin number locking 

The lock feature allows you to lock 2 different aspects of 
the system using a pin number. You can either lock the 
heater completely so that it cannot be tampered with, 
or  only  lock  the  WIFI  pairing.  Locking  the  WIFI  pairing 
prevents  people  from  pairing  the  heater  to  their 
smartphones unless they have the pin.  
These  settings  can  be  implemented  under  the  title 

‘Lock’  in  the  settings  menu.  You  cannot  view  the  lock 

settings until the WIFI pairing lock is enabled. 
 
To disable the pairing lock via the timer, hold down the 

TIME  and  PROG  buttons.  To  disable  the  heater  lock  via 
timer, hold down the TIME and TEMP buttons. 
This  will  prompt  you  to  enter  a  4-digit  pin.  Enter  the  4-
digit  pin  using  the  TEMP  and  MODE  buttons  to  select  a 
value, the TIME button to advance to the next digit, and 
the PROG button to confirm. 
 
Once the pin has been entered, the lock is disabled and 
the pin does not need to be re-entered. 
 

NOTE: 

Once this pin has been confirmed, the lock can-

not be removed without knowing the correct pin num-
ber.  
 

The pin is NOT recoverable. 

20. Occupancy sensor (MWIFI models only) 

In order to detect movement in the room, the heater has 
a built in microwave sensor. For the occupancy detection 
to work correctly it is necessary to find the right settings for 
the sensor. This will minimise erroneous triggering.  
All settings can be changed using the Consort Connect 

app. This can be done under the title ‘Occupancy Sensor’ 

in the settings menu. 

 

There are 3 values which can be changed. These are the 

sensitivity

responsiveness 

and the 

occupancy timeout

.  

 
The value for 

sensitivity

 adjusts the point at which a dis-

turbance counts toward the decision to trigger the heater. 
It is adjustable from 0 to 9 which adjusts the sensitivity. 0 is 
minimum sensitivity, 9 is maximum sensitivity. Setting sensi-
tivity to the minimum setting (zero) disables the sensor. 
 
The value for 

responsiveness

 is used to consider several 

readings before triggering occupancy. This value is also 
adjustable from 0 to 9, the higher it is set the less sensor 
readings are required to trigger occupancy. 0 is minimum 
responsiveness, 9 is maximum responsiveness. 
 
The 

occupancy timeout 

is the length of time the heater 

stays on for without movement being triggered. 

 

How does the microwave sensor work? 

The occupancy sensor works differently depending on 
what operating mode is manually selected.  

 

When in MANUAL mode, the microwave sensor will  switch 
the heater into FROST mode automatically when the oc-
cupancy timeout is reached. The app display will then 

show ’Auto off’. When this is shown, the heater will switch 

back to manual mode automatically once movement is 
detected.  

 

When  in  automatic  mode,  the  heating  will  automatically 
switch off when the occupancy timeout is reached. It will 
then  switch  back  on  when  movement  is  detected.  The 
preheat  function  is  unaffected  by  this  and  operates  as 
normal. 

19. Self-learning mode (MWIFI models only) 

21. Energy consumption 

Selecting the         icon will load the Energy consumption 
menu.  This menu shows how  much power the individual 
heater has used in the last day, week, month and year.  
 
The  energy  usage  values  are  approximate.  They  are 
based  on  recording  time  the  heaters  are  producing 
heat.  The  mains  voltage  and  actual  heater  wattage 

aren’t taking to account when calculating  values.

 

This mode allows the heater  to monitor movement 
patterns and predict when people are likely to use the 
room. Once a pattern is detected, the heater  will add 
the pattern to the automatic timer. The learning mode 
will only switch the heater on automatically if the product 
is left in auto mode. 
Occupancy  sensor  data  is  recorded  in  a  week  period. 
Time  is  divided  up  into  hour  segments.  Any  occupancy 

detected  during  the  hour  counts  as  an  ‘occupied’ 

segment in the data. There are 2 different learning mode 
options  available,  2  weeks  and  3  weeks.  The  default 
mode  is  the  2  week  learning  period.  In  this  operating 
mode,  if  there  are  readings  of  occupancy  at  the  same 
time  and  day  3  weeks  in  a  row,  then  a  pattern  is 
detected and added to the automatic timer. In 2 week 
mode,  only  2  consecutive  weeks  are  required.  The 
parameters  can  be  changed  via  the  app.  To  do  this, 

enter the settings menu and select the title ‘self

-learning 

programme’. 

 

After the 

self-learning function 

is enabled, 

the heater will start overwriting the existing 

time schedules immediately. It is 

recommended to leave the heaters in manual 

mode with occupancy sensor enabled for the 

period of 2 or 3 weeks to allow the time 

schedules to be  recognised by the heaters. 

Содержание PLE050MWIFI

Страница 1: ...dified or repaired by any person not authorized by us This guarantee is offered to you as an extra benefit and does not affect your legal rights The correct electricity supply voltage is shown on the...

Страница 2: ...d Cut Out The appliance is fitted with a thermally operated cut out TOC This is a safety device which switches the heater off if for any reason the appliance overheats The TOC can only be re set after...

Страница 3: ...LE100WIFI MWIFI 1000 614 477 PLE125WIFI MWIFI 1250 720 582 PLE150WIFI MWIFI 1500 720 582 PLE200WIFI MWIFI 2000 852 713 Fig 1 3 See Note 16 for Mounting The heater MUST be fully secured in the vertical...

Страница 4: ...Once the temperature is set leave the display to return to the main screen and the settings will be saved 4 BOOST 15 minutes The boost feature increases the room temperature for 15 minutes 1 Use TEMP...

Страница 5: ...temperature For example should the display read 10 22 the heater would maintain a temperature of 22 C between 10am and 11am Once the time has passed 11am it will move to program 11 Setup instructions...

Страница 6: ...o change a value 4 Use TIME to scroll between the settings 01 temperature calibration The temperature reading has been factory calibrated but if for any reason it needs adjusting better accuracy requi...

Страница 7: ...minimum sensitivity 9 is maximum sensitivity Setting sensi tivity to the minimum setting zero disables the sensor The value for responsiveness is used to consider several readings before triggering o...

Страница 8: ...the app it is given a gener ic name and icon These can both be changed To do this when the controller menu is open this is the menu you can control the product with select the icon in the top right co...

Отзывы: