Consort PLC050/SS Скачать руководство пользователя страница 4

 

 

66000652 Iss 01 

Controls 

 
When the appliance is connected to the mains 
supply and the wall socket is switched ‘ON’ the 
mains neon indicator will light, showing that the 
power is available to the unit. 

continuously. Set the current time of day onto the timer 
by rotating the dial face clockwise until the correct 
time is indicated against the timer reference mark on 
the 24-hour clock face. For frost protection mode, 
move the switch immediately beneath the timer to the 
manual position designated       . 

 

Automatic Operation

 

 
Move the switch immediately beneath the timer to the 
auto position designated by the clock icon. The 24-hour 
timer can be set to give any combination of On/Off 
intervals to a minimum of 20 minutes on. 
 

• 

Select the ‘On’ time required by pressing the 
black segment (on the circumference of the 
timer) adjacent to the time required outwards.  
This will cause the heater to switch ‘On’ at the 
selected time for 20 minutes operation.  Each 
additional segment pressed out will give a further 
20 minutes of operation.  In this way, select the 
length of time required for the unit to be ‘On’ 
and push out the number of 20-minute segments 
necessary to select the time period required. 

 
The timer can be set to give as many ‘On’ periods as 
required during any 24-hour period.  This program will 
repeat itself every 24 hours until changed.  This program 
may be overridden at any time by switching to manual 
operation. 
 

Manual Operation 

 
Move the selector switch beneath the timer to the 

manual position designated by the hand icon.  The 
heater will now run continuously, controlled by the heat 
settings and thermostat as described under the 
‘Controls’ section.  
 

Mounting 

 
To wall mount, the wall bracket supplied must be used. 

Please refer to illustrations in Fig.1. 

Remove wall bracket 

from the heater. Fix wall bracket to wall using screw 
holes provided. Present heater to bracket. Locate 
heater onto bottom lugs via 2 sets of relevant slots in 
rear panel.  Hinge heater upwards and locate the top 
tabs into the slots in the back of the heater and ‘click’ 
into position. 
 
To remove the heater from the wall first disconnect the 
power then press down on the two top tabs to release 
the heater. Hinge the heater forward on the bottom 
lugs. The heater can be now lifted off the bottom lugs 
to remove it from the wall. The heater must not be 
located immediately below a fixed socket outlet. 

NOTE: 

On the non-timer models there is no timer 

control and selector switch. 
 
The controls (except NC models) are located 
behind a cover on the right hand end of the 
appliance. The heaters (except the NC models) 
are fitted with a build-in thermostat to control the 
temperature level to which the room is heated.  
The thermostat adjustment knob is located on the 
right hand end and is numbered.  Rotate the 
knob clockwise to a higher number against the 
thermostat reference mark to raise the room 
temperature.  Once set it is unlikely to require 
being touched again. To set the heater to the 
Frost Watch mode, ensure that at least one heat 
switch is in the on position and turn the 
thermostat control knob fully anti-clockwise until 
the frost symbol aligns with mark. 
 

Using the Timer (TI Models only) 

 

The heater must be connected to the mains 
supply in order for the timer to operate 

Timer reference 
mark 

Selector switch 

Thermostat reference 
mark 

Heat Switches (Each 
gives half heat, both 
depressed - full heat 

Thermostat 
adjustment knob 