When the appliance is connected to the mains
supply and the wall socket is switched ‘ON’ the
mains neon indicator will light, showing that the
power is available to the unit.
4
continuously. Set the current time of day onto the timer
by rotating the dial face clockwise until the correct
time is indicated against the timer reference mark on
the 24-hour clock face. For frost protection mode,
move the switch immediately beneath the timer to the
manual position designated .
Automatic Operation
Move the switch immediately beneath the timer to the
auto position designated by the clock icon. The 24-hour
timer can be set to give any combination of On/Off
intervals to a minimum of 20 minutes on.
•
Select the ‘On’ time required by pressing the
black segment (on the circumference of the
timer) adjacent to the time required outwards.
This will cause the heater to switch ‘On’ at the
selected time for 20 minutes operation. Each
additional segment pressed out will give a further
20 minutes of operation. In this way, select the
length of time required for the unit to be ‘On’
and push out the number of 20-minute segments
necessary to select the time period required.
The timer can be set to give as many ‘On’ periods as
required during any 24-hour period. This program will
repeat itself every 24 hours until changed. This program
may be overridden at any time by switching to manual
operation.
Manual Operation
Move the selector switch beneath the timer to the
manual position designated by the hand icon. The
heater will now run continuously, controlled by the heat
settings and thermostat as described under the
‘Controls’ section.
Mounting
To wall mount, the wall bracket supplied must be used.
Please refer to illustrations in Fig.1.
Remove wall bracket
from the heater. Fix wall bracket to wall using screw
holes provided. Present heater to bracket. Locate
heater onto bottom lugs via 2 sets of relevant slots in
rear panel. Hinge heater upwards and locate the top
tabs into the slots in the back of the heater and ‘click’
into position.
To remove the heater from the wall first disconnect the
power then press down on the two top tabs to release
the heater. Hinge the heater forward on the bottom
lugs. The heater can be now lifted off the bottom lugs
to remove it from the wall. The heater must not be
located immediately below a fixed socket outlet.
NOTE:
On the non-timer models there is no timer
control and selector switch.
The controls (except NC models) are located
behind a cover on the right hand end of the
appliance. The heaters (except the NC models)
are fitted with a build-in thermostat to control the
temperature level to which the room is heated.
The thermostat adjustment knob is located on the
right hand end and is numbered. Rotate the
knob clockwise to a higher number against the
thermostat reference mark to raise the room
temperature. Once set it is unlikely to require
being touched again. To set the heater to the
Frost Watch mode, ensure that at least one heat
switch is in the on position and turn the
thermostat control knob fully anti-clockwise until
the frost symbol aligns with mark.
Using the Timer (TI Models only)
The heater must be connected to the mains
supply in order for the timer to operate
Timer reference
mark
Selector switch
Thermostat reference
mark
Heat Switches (Each
gives half heat, both
depressed - full heat
Thermostat
adjustment knob