68000801 Iss 02 

Fig 2 – Mounting Slot 

Model 

PHRX2 

500 

456 

95 

22 

PHRX3 

600 

540 

95 

30 

 

I

NSTALLATION 

R

ECOMMENDATIONS

 

 

 

It is recommended that careful thought be given to siting the appliance within the room.  

Try to avoid being directly in front of the heater for long periods.  Consider where you may 
stand, at a work surface or the like.  Position the heater to deliver the benefit of its warmth 

but not so as to overheat yourself. 
 

The heater must not be located immediately below a fixed socket outlet.

 

 

 

I

NSTALLATION 

R

EQUIREMENTS

 

 

 

The appliance is designed to fit behind the 

plinth board and below the base shelf of a 

kitchen-type cupboard ie within the free plinth 
space.  Figure 1 below shows the MINIMUM size 

cupboard unit into which the appliance may be 
fitted. 

 
  The appliance may be installed into a 

cupboard with dimensions larger than those 
given above. 

 
 
 

I

NSTALLATION PROCEDURE

 

 

1.

 

Cut a hole in the plinth board, to the 

dimensions given in Figure 2. 

2.

 

The power supply cable must be routed from 

the connecting unit into the plinth space.  The 
cable shall be sufficiently long as to pass 

through the plinth space and plinth board.  
This enables the appliance to be subsequently 

withdrawn from the plinth if maintenance is 
required.  Ensure no sharp edges are present 

along the power cable route. 

3.

 

The appliance can now be slid through the 

plinth board, until the fascia panel abuts the 
outside of the plinth board.  Screw the 

fascia panel to the plinth board with the 
screws provided. 

4.

 

Connect the unit to the mains power supply 
in accordance with the appropriate section 

of these instructions. 
 

To remove the appliance from the plinth space, should maintenance be required, 

disconnect mains power supply, unscrew fascia panel and slide out the appliance. 

 
These dimensions are for a 500mm (PHRX2) and 600mm (PHRX3) wide by 100mm (min) 

high plinth.  If the appliance is to be fitted into a plinth greater in length than specified then 
the hole shown in Figure 2 must be cut at least 22mm from one end. 

 

 

 

A

IRFLOW

 

 
 

 
 

 
 

 
 

 
 

O

PERATION

 

 

This  heater  can  only  be  used  when  connected  to  a  CRX2  wireless  programmable  timer.  

Each CRX2 can control any number of heaters.  The heater has an indicator light positioned on 
the fascia.  The light may be: 

 
Green 

- 

when no heat is needed 

Yellow 

- 

when some heat is needed to maintain the room temperature 

Red 

- 

when the heater is on full power 

Fast Flashing Red   -   when the heater has overheated and the Electronic Safety Control 
 

 

 

has switched the heater off. 

 
Please refer to the CRX2 user and operating instructions for full operational details. 

 

E

LECTRONIC 

S

AFETY 

C

ONTROL

 

 

 

The appliance is fitted with an electronic Safety Control (ES).  This is a safety device which 

switches off the heater if, for any reason, the appliance overheats.  Overheating is indicated 

by a fast flashing red light.  The ES Controls can only be reset after the appliance has cooled 
down.  In order to reset the ES Control proceed as follows: 

1.

 

Switch off appliance and leave for approximately 5 minutes. 

2.

 

Switch on appliance and the ES Control will reset. 

3.

 

Ensure that the appliance is functioning correctly.  If the ES Control operates again, 
the appliance should be checked by a competent electrician. 

 

C

ONNECTION TO THE 

M

AIN 

S

UPPLY

 

 

 

Electrical installation should be carried out by a competent installer, preferably registered 

with NICEIC (National Inspection Council for Electrical Installation Contracting) in accordance 
with the 16 edition of the IEE Wiring Regulations, (BS.7671), and any relevant Local Authority 

bye-laws. 
  This heater is fitted with a 3-core mains supply cable and should be permanently 

connected to the electricity supply via a double pole switch having 3 mm gap on each pole. 
  A switched Fused Connection unit to BS.1363 Part 4 is a recommended mains supply 

connection accessory to ensure compliance with safety requirements applicable to fixed wiring 
installation.

 

 

 

UNIT REF 

 

PHRX2 

 

PHRX3 

 

A - Width 

500mm 

600mm 

B - Plinth Height 

100mm 

100mm 

C - Base Shelf 

75mm - max 

75mm - max 

D - Depth 

500mm 

500mm 

 

Отзывы: