5
I3984069 Iss 03
22. Power adapter for fixed installation (cont’d)
23. Open Window Detection
locking screws
USB power ports
temperature sensor
wall fixing
wall fixing
The CRX2 is guaranteed for one year against faulty material or workmanship. This applies only if the appliance has been used for
purposes in accordance with the instructions provided and has not been misused, neglected, damaged, modified or repaired
by any person not authorised by us. This guarantee is offered to you as an extra benefit and does not affect your legal rights.
Reasonable care has been taken to ensure that this guide is accurate at the time of printing. In the interest of progress, the
Company reserve the right to vary specifications from time to time without notice.
Should you need any advice on the use of you new Consort product please contact our Helpline:
Consort Equipment Products Limited
Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT
Tel: 01646 692172 | Fax: 01646 695195
Email: [email protected] Web: www.consortepl.com
Operation hours: Mon to Thu 8.30am to 4.30pm | Fri 8.30am to 3.30pm
BS EN ISO 9001 Registered Company No FM12671
Customer Helpline
24. Setup menu
1.
Touch and hold and icons together for 10
seconds.
2.
The CRX2 will enter the setup menu.
3.
Use and to change a value.
4.
Use to scroll between the settings.
01 – temperature calibration
The temperature reading has been factory calibrated but if
for any reason it needs adjusting (better accuracy required,
to suit different position in the room etc.), the reading can be
recalibrated in 0.5 degrees steps.
Please note that if the unit is powered by the power adapter, the
temperature reading REQUIRES recalibration. Lower the value by 1.5
degrees.
02 – change between degrees Celsius or Fahrenheit
03 – set minimum temperature
(- - - = heating OFF, 4deg = frost protection)
04 – set maximum temperature
05 - information about the software version
06 - 0 or 1 manual mode enable / disable
07 - open window detection 0 = off, 1 = on
08 - 600 - open window detection time 600 seconds
09 - 2 - temperature drop of 2°C in the detection time
10 - 30 - closed window detection time of 30 seconds
11 - 2 - temperature rise of 2°C in the detection time
Ensuring you don’t waste energy on heating the outside
world, the heater is equipped with optional open /
closed window detection. The heater recognises sudden
drops in temperature when a window or a door is
opened and turns the heating off to save energy. When
the window is closed, the heater will automatically
detect a temperature rise, and switch itself back on.
Once enabled in the setup menu, the open window
detection is fully automatic and does not require any
human intervention to be activated.
Setting-up Open Window Detection
The system has been factory set to default time and
temperature values. If necessary, all values can be
adjusted. When the heating is on, open window
detection sensor will automatically switch the heater off
when it detects a fall in temperature of 2
°
C in less than
10 minutes (this temperature can be changed in menu 7
and time in menu 6). If a temperature rise of 2
°
C in less
than 30 seconds is detected, the heater will switch itself
back on (this temperature can be changed in menu 9
and time in menu 8).