background image

 

 

64000284 Iss 01 

Important 

 

When installed in a bathroom the unit must not be 
connected via a plug and socket. 

The heater must also be located in the appropriate 
zone of the bathroom, in accordance with section 
701 of the Wiring Regulations BS 7671).  The appliance 
should be fitted horizontally such that the cable entry 
is uppermost.  The unit must be mounted a minimum 
of 1.8 metres from the floor, also a minimum of 150mm 
below ceiling level or any other projecting surface.  It 
must also not be less than 350mm from any adjacent 
projecting surface.  The unit must not be located 
immediately below a fixed socket outlet.  

The heater is to be installed so that the appliance 
cannot be touched by a person in the bath or 
shower. The heater must not be installed in front of a 
socket-outlet.   

Means for disconnection must be incorporated in the 
fixed wiring in accordance with the wiring rules.  If the 
supply cord is damaged, it must be replaced by the 
manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard. 

Ensure that when in use the airstream is not 
obstructed. 

 

Warning – Do NOT place aerosols or similar containers 
or materials susceptible to heat in the direct airstream. 

 
Mounting Procedure 

Using the mounting template supplied, position it 
horizontally a minimum of 1.8 m from floor to 
underside and mark the position of the three fixing 
holes. 

Drill and plug the wall suitable for No 8 screws. 

Insert the two keyhole screws in wall leaving 
approximately 2 mm gap between head and wall. 

Position the appliance on the partially inserted wall 
screws and secure the third wall screw immediately 
above appliance. 

 

 
This heater can only be used when connected to any 
SL wireless controller
.   
 
Each SL controller can control any number of heaters 
providing they are in the RF range. 

SLPB 

SLTI 

SLVT 

Operation 

 

When the appliance is connected to the mains supply, 
the LED indicator will light up green, showing that the 
power is available to the unit. 
 
When the heat output has been enabled by a 
controller, the LED indicator light will turn red. 

Please refer to the SL installation and control guide for 
full operational details. 

SL wireless controllers 

SLVTB 