background image

Consilium Building Safety AB

Phone:

+46 31 28 59 40

Fax:

+46 31 28 85 95

E-mail:

[email protected]
[email protected]

 
The contents of this document are subject to revision without notice
due to continued progress in methodology, design and
manufacturing. Consilium Building Safety AB assumes no legal
responsibility for any error or damage resulting from the usage of
this document.
 
January 2014
Document no. 5103029_Salwico ST400 O2_Calibration Instruction_I0_EN_2014_B

Part no. 5103029

© Copyright 2014, Consilium Building Safety AB

Содержание Salwico ST400 O2

Страница 1: ...Salwico ST400 O2 Salwico GS5000 Calibration Instruction ...

Страница 2: ... to revision without notice due to continued progress in methodology design and manufacturing Consilium Building Safety AB assumes no legal responsibility for any error or damage resulting from the usage of this document January 2014 Document no 5103029_Salwico ST400 O2_Calibration Instruction_I0_EN_2014_B Part no 5103029 Copyright 2014 Consilium Building Safety AB ...

Страница 3: ...an of the sensor is about one year and it has a short shelf life stocking it on board is not advised and this will reduce the operational lifetime Consilium Replacement article for sensor only of ST400 O2 detector is no 004472 A new sensor is supplied without the metal housing and must be fitted in the housing This applies to both H2S and O2 sensors of ST400 type Calibration equipment The O2 is ca...

Страница 4: ... 2 Prerequisites 1 Use the arrow keys on the control panel to manoeuvre through the different menus Press the right arrow key to access the menu tree 2 Scroll to 4 Gas Detectors and press Continue 3 Scroll to the detector that should be calibrated and press Options 4 Scroll to 3 Disable and choose Continue 5 You have to confirm the disablement before you can proceed Press Disable to continue ...

Страница 5: ... 17 4 mA signal even with the SPAN potentiometer in max position 1 Connect a Multi meter set to mA to the test points and adjust the readout on the SPAN pot to 17 4 mA when normal breathing air is present 1 4 Calibrating the sensor Zero calibration For Zero adjustment a Nitrogen mix should be used with a pure N2 Nitrogen concentration A gas bottle with Hydrocarbons in N2 can also be used as long a...

Страница 6: ...ction_I0_EN_2014_B 1 5 Reconnecting disabled detectors All disablements in the Salwico GS5000 gas detection system are presented in the disablements list Any enablement is made from this list 1 Scroll to Menu Disablements 2 Choose the detector you just disabled and press Options 3 Select Reconnect and press Continue ...

Страница 7: ...Calibration Instruction 1 Calibration Instruction for Salwico ST400 O2 5103029_Salwico ST400 O2_Calibration Instruction_I0_EN_2014_B 5 ...

Страница 8: ...www consiliumbuildingsafety com ...

Отзывы: