Conrad FP500 Скачать руководство пользователя страница 4

3. Step: Programming User Fingerprints

After the master was programmed, any other authorised "user fingerprints" can be programmed.
Clearance by the master fingerprint is required, however, to prevent programming of any undesired users!

To programme the user fingerprint, proceed as follows:

1. Set jumper "J1". "LED1" goes out after approx. 10 seconds. The "LED2" and "STATUS LED" light up.
2. Now the master fingerprint is required for clearance! For this, the "master finger" must be pulled over

the sensor (as described in "Correct Sensor Operation"). When the master fingerprint was recognized
successfully, "LED1" lights up to indicate readiness for programming new user fingerprints.

3. Now put the desired user finger in place and pull it out over the sensor. If the fingerprint was programmed

correctly, "LED1" goes out for approx. one second, and "STATUS LED" lights up for that time. This
programming procedure may have to be repeated several times depending on the quality of the
fingerprint recorded (approx. five times). If "LED1" and "LED2" flash twice, this indicates that the
programming procedure for the authorised user was completely successfully.

If other users are to be programmed, repeat no. 3.

4. If you want to exit the programming process, remove jumper "J1". After approx. 30 seconds, your

information is computed and encoded. "LED1" and "LED2" light up.
The user programming process is now completed.  Replace the cover of the evaluation unit. The device
is ready for operation.

Note:

When "LED2" lights up during the programming process of the "user fingerprints",
clearance by the master fingerprint must be repeated (see "no. 2").
If the memory is full, "LED1" and "LED2" will flash 5 times.
Never forget to remove jumper "J1" after completing the programming, or the device will
remain in programming mode!
The change from programming mode to any other operating mode takes approx. 30
seconds.

Operation (Relay Operation)

In normal operating mode (relay mode), the two jumpers "J1" and "J2" must not
be inserted.
In this mode, "LED1" and "LED2" are lit and the "STATUS LED" is off. (if "J1"
and "J2" are inserted but the USB socket is not connected to a computer, the
device is in relay mode, too)

For operation, proceed as follows:

1. Insert the respective finger to the deep stop as usual and pull it over the sensor as described in "Correct

Sensor Operation". When the finger is inserted "LED2" goes out, and after it is pulled out, "LED1" goes
out.

2. If the fingerprint was recognized, this is confirmed by "LED1" and "LED2" lighting up shortly, and the

switching contact is activated for three seconds (or the time set by the computer software.

3. When "LED1" and "LED2" are lit again, the module is ready for the next recognition.

Error message of LED1 and LED2 / fingerprint was not detected

If a reading attempt does not recognise the fingerprint, this is indicated after no more than 10 seconds by
"LED1" and "LED2" blinking fast for three times. Repeat the reading process again when the two LEDs
("LED1" and "LED2") are lit again.

A short flickering of "LED1" and "LED2" during operation is system-related and does not
indicate any defect.

Resetting to Default Settings (Deleting the programmed fingerprints)

The programmed fingerprints can only be deleted altogether. Individual deletion is not
possible without the PC software.

To delete all fingerprints (including the master!), proceed as follows:

• If applicable, remove all jumpers from the evaluation unit.
• Insert the "J2" jumper and wait for approx. 20 seconds until "LED1" goes out.
• After this time (and not before), all memorized fingerprints are deleted.
• The switching time of the relay is reset to approx. three seconds.
• Remove jumper "J2". The module is back in its default state.

Hardware Reset

If "LED1" and "LED2" do not show any reaction to touching the sensor caused by external influence like
voltage peaks, wrong operation or forgetting to pull of the jumpers, the operating voltage has to be
interrupted at the "POWER" clamp for 20 seconds. The programmed fingerprint data is preserved.

PC Mode (USB Interface)

Install the drivers before connecting the device to the PC! For this, first read the instructions
on the fingerprint access system software CD.

The fingerprint module has a USB interface. It can be used to connect to a computer through a USB cable
(type A plug to mini USB plug).
The included software provides a number of other functions for making operating of the system and
managing the fingerprints easier. The relay switching time may also be adjusted from approx. 1 to 30
seconds within the software.
To install the software, insert the provided CD in the respective drive of your computer and run the file
"setup.exe" in the root directory of the CD. Follow the instructions (see "readme.txt" for "Notes on
installation").

Operating Modus Overview

In the following table, "x" indicates an attached jumper, "-" indicates a removed jumper. "J1" and "J2" are
on the evaluation unit.

J1

J2

Mode

 -

 -

Normal (Relay operation)

 x

 -

Programming mode (after 10 seconds)

 -

 x

(> 30 seconds) Deletion of fingerprints / reset default settings

 x

 x

USB connected: PC mode
USB not connected: Normal (Relay operation)

Disposal

Electronic products are raw material and do not belong in the household waste. When the
device has reached the end of its service life, please dispose of it, according to the current
statutory requirements, at your local collecting site. It is prohibited to dispose of the device
in the household waste.

Technical Data

Operating Voltage ....................................... 12 V/DC or 8 V/AC +/-15%
Power input ................................................. max. 200 mA, stand-by approx. 80 mA
Possible fingerprints (depending on size) . approx. 100 (incl. master)
Switching output relay: ............................... 35 V/AC or 35 V/DC, 3 A
Switching time ............................................. Default setting 3 seconds

(by PC software adjustable 1-30 seconds)

Interface ...................................................... USB ("Mini-B" socket)
Weight (without installation adapter) ......... approx. 105g
Dimensions evaluation unit ........................ Approx. 60 mm x 54 mm x 33 mm (L x W x H)
Protection level of the evaluation unit ........ IP30
Reading unit dimensions: ........................... Approx. 80 mm x 80 mm x 48 mm (L x W x H)
Protection level of the reading unit ............ IP44

(front-side in assembled state, front-flap closed)

Length of the connection cable .................. approx. 50 cm

These operating instructions are a publication by Conrad Electronic SE, Klaus-
Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment
reserved.

© Copyright 2010 by Conrad Electronic SE.

Содержание FP500

Страница 1: ...Einheit den Master Finger nicht beim ersten oder zweiten Versuch erkennen kein h rbares Klicken des Relais l schen Sie die Daten des Moduls wie in Punkt R cksetzen auf Werkseinstellungen L schen der...

Страница 2: ...L schen der eingelesenen Fin gerabdr cke Die eingelesenen Fingerprints k nnen nur gesamt gel scht werden Einzelne L schungen sind ohne die PC Software nicht m glich Zum L schen aller Fingerprints auch...

Страница 3: ...e relay will close for approx three seconds If the unit does not detect the master finger at the 1st or 2nd attempt the relay does not click delete the module data as described in Reset to default set...

Страница 4: ...r Individual deletion is not possible without the PC software To delete all fingerprints including the master proceed as follows If applicable remove all jumpers from the evaluation unit Insert the J2...

Страница 5: ...alis e par l allumage bref de LED1 et LED2 Puis le relais est actif pendant trois secondes environ Si l unit n identifie pas le doigt ma tre lors de la premi re ou de la deuxi me tentative le relais n...

Страница 6: ...giciel PC Pour effacer toutes les empreintes digitales m me l empreinte ma tre proc dez comme suit Enlevez tous les cavaliers enfich s de l unit d valuation Mettez le cavalier enfich sur J2 et attende...

Страница 7: ...de mastervinger niet bij de eerste of tweede poging geen hoorbaar klikken van het relais wis dan de gegevens van de module zoals bij Herstellen van de fabrieksinstellingen Wissen van ingelezen vingera...

Страница 8: ...e ingelezen vingerafdrukken kunnen alleen compleet worden gewist Individuele oplossingen zijn zonder PC software niet mogelijk Voor het wissen van alle vingerafdrukken ook master gaat u als volgt te w...

Отзывы: