3.8 Fault warning silence

When the device is in a fault state, press the TEST/SILENCE button, it 

will enter the fault warning mute state for about 9 hours, while dis-

playing „     „ on the LCD, and the FAULT indicator (yellow) remains 

flashing.

NOTE: The silence feature of fault warning is a temporary action to 

cancel warning sound effect, you need replace the device as soon 

as possible.

3.9 End-of-life warning

If the device chirps 3 times every 40 seconds with FAULT indicator 

(yellow) flash and the LCD displays ‘End’. It indicates end of life of CO 

alarm. You need to immediately replace the CO alarm.

3.10 End-of-life warning silence

When the device is in the End-of-life state, press the TEST/SILENCE 

button, it will enter the End-of-life warning mute state for about 9 

hours, while displaying „       „ on the LCD, and the FAULT indicator 

(yellow) remains flashing.

NOTE: The silence feature of fault warning is a temporary action to 

cancel warning sound effect, you need replace the device as soon 

as possible.

3.11 Test the device

When the device under normal operation status, you can test the 

device by TEST/SILENCE button, PRESS and HOLD the TEST/SILENCE 

button, you should hear alarm sound pattern (<85dB) and with a cor-

responding ALARM indicator (red) flash. After the eighth sound, the 

device will issuing a normal alarm volume (≥85dB). Test process will 

stop when release the button. The LCD displays all segments during 

testing.

NOTE: After the TEST/SILENCE button is enabled, the alarm sounds 

and the red alarm light flashes. This does not indicate that CO is 

present.

NOTE: Test the device every year! If at any time your device does 

not perform as described, replace it immediately.

3.12 Automatic brightness adjustment

Automatic brightness adjustment of POWER indicator (green). If the 

ambient brightness is very low (night, indoor & lights off). The flas-

hing brightness of the POWER indicator (green) will be reduced, so 

as to reduce the impact of the standby indicator light

on people.

NOTE: This function does not affect the brightness of the ALARM 

indicator (red) and the FAULT indicator (yellow).

3.13 Weekly test

Recommend test the alarm weekly by pressing the TEST/SILENCE 

button to ensure the normal operation of the equipment.

3.14 Alarm memory

48 hours alarm memory function. When the device detects CO and 

alarms, when the device return to standby mode, and the CO concen-

tration <20PPM, LCD displays „AL“ and ALARM indicator (red) flash 

per 40 seconds. After press TEST/SILENCE button or after 48 hours, 

will reset the historical memory function and enter normal operation 

status.

4. What to do if the alarm sounds

WARNING! – Actuation of your CO alarm indicates the presence of 

Carbon Monoxide (CO) which can KILL YOU.

WARNING! – Action of this device indicates the presence of dan-

gerous levels of CO! CO can be fatal!  

 

If the alarm sounds:

4.1 Keep calm and open all doors and windows to increase the rate 

of ventilation. Stop using all fuel-burning appliances and ensure, if 

possible, that they are turned off, e.g. for gas appliances, isolate the 

emergency control valve;

4.2 If the alarm continues to be activated, then evacuate the premi-

ses. Leave the doors and windows open, and only reenter the buil-

ding when the alarm has stopped. In multi-occupancy and multi-sto-

rey premises, ensure that all the occupants are alerted to the risk;

4.3 Get medical help for anyone suffering the effects of carbon mon-

oxide poisoning, and advise that carbon monoxide inhalation is su-

spected;

4.4 Telephone the appropriate appliance servicing and/or mainte-

nance agency or, when necessary, the relevant fuel supplier on their 

emergency number or the national Gas Emergency Service Provider, 

if appropriate, so that the source of carbon monoxide emissions can 

be identified and corrected. Unless the reason for the alarm is obvi-

ously spurious, do not use the fuel-burning appliances again, until 

they have been checked and cleared for use by a competent person 

according to national regulations.

5. Battery installation/replacement

Once chirps with corresponding FAULT indicator (yellow LED) flas-

hing once every 40 seconds indicates that the battery is low battery, 

you must to replace with battery specified, please see “8. Specifica-

tion“.

To install or replace the battery in unit, please perform the following 

steps:

5.1 Take down the unit from screw heads of the wall.

5.2 Open battery compartment.

5.3 Remove the old battery, and replaced by new battery.

5.4 Put the battery into the battery box.

5.5 Hook the alarm over the screw heads onto keyholes in back of 

the unit.

5.6 Test alarm using the TEST/SILENCE button, if the testing alarm is 

ok, means the product can work normally.

WARNING! - Use only the battery specified. Use of different battery 

may have a detrimental effect on the CO alarm. A good safety mea-

sure is to replace the battery at least once a year.

CAUTION: Please replace new 2pcs same type batteries in the me-

antime.

CAUTION: Test the alarm for correct operation using the TEST/SI-

LENCE button, whenever the battery is replaced!

6. Gerneral maintenance

To keep your CO alarm in good working order, please follow these 

simple steps: