6. Notes on batteries and rechargeable batteries

For safety reasons, the smoke detector should not be operated using recharge-
able batteries.

Due to the its low voltage (rechargeable battery = 1.2V, battery = 1.5V) the
smoke alarm may perceive that the rechargeable battery is low even though it
is fully charged. It then emits a soft signal tone every 48 seconds and the red
LED blinks three times every 48 seconds.

Therefore, please make sure that you only use high-quality alkaline batteries
(Conrad item no. 650117, for example. Order 3 batteries).

• Keep batteries (and rechargeable batteries) out of the reach of children.

• Make sure that the polarity is correct when inserting the batteries.

• Do not leave batteries/rechargeable batteries lying around as they could be swallowed by

children or pets. In such case seek immediate medical care.

• Leaking or damaged batteries/rechargeable batteries may cause acid burns, if they come

into contact with skin. Therefore, please make sure you use suitable protective gloves.

• Make sure that batteries/rechargeable batteries are not short-circuited, taken apart or

thrown into fire. They might explode!

• Conventional batteries must not be recharged. They might explode!

• If the device is not used for a longer period of time (when stored, for example), remove the

inserted batteries. This way, you can prevent the aging batteries from leaking and causing
damage.

For safety reasons, the device’s casing cannot be locked, if no batteries
have been inserted!

Содержание 75 06 66

Страница 1: ...Version 12 06 OPERATING INSTRUCTIONS Radio smoke detector RM 100 2 Uni S Item no 75 06 66...

Страница 2: ...ff 16 d Starting the sensor search on the HMS 100 Z 17 e Inserting the batteries into the smoke detector 18 f Starting the sensor search on the HMS 100 Z 19 g Locking the smoke detector into its socke...

Страница 3: ...n the radio range 32 16 Maintenance and cleaning 33 17 Disposal 33 a General information 33 b Batteries and rechargeable batteries 33 18 The smoke detector s signal output 34 19 Declaration of conform...

Страница 4: ...these operating instructions Please read the operating instructions completely and observe the safety and operation notes before using the product All company names and product names contained herein...

Страница 5: ...llows rooms to be monitored whose current conditions make radio monitoring technically difficult For further information please see section 7 The radio smoke detector should not be used in environment...

Страница 6: ...th a lightning flash in a triangle is used to alert you to potential personal injury hazards such as electric shock The icon with an exclamation mark in a triangle points to important instructions in...

Страница 7: ...on or installation you are not sure or have doubts about how to proceed contact a skilled technician For safety and licensing CE reasons any unauthorised alterations to and or modification of the prod...

Страница 8: ...larity is correct when inserting the batteries Do not leave batteries rechargeable batteries lying around as they could be swallowed by children or pets In such case seek immediate medical care Leakin...

Страница 9: ...the HMS 100 hazard detection system or the FHZ 1000 home radio central unit This ensures that a fire which is some distance away on another floor of the house for example can be responded to in good...

Страница 10: ...ough a closed bedroom door The smoke detector should always be mounted to the centre of a room s ceiling Bedroom Hallway Study Living room Children s room Entrance area Kitchen Minimal protection Reco...

Страница 11: ...that rising smoke does not reach the smoke detector or it reaches it too late We generally recommend that the smoke detector be mounted to the ceiling in the centre of a room However you should make...

Страница 12: ...me less sensitive so that the alarm is activated later or not at all Places with a strong movement of air Late smoke detection and alarm due to the proximity of windows fans lamps lamp tubes halogen t...

Страница 13: ...g an installation box B Holder for cable ties C Alternative installation using spacers You can use the two mounting holes to screw the lower plate securely to a wall or a ceiling for example Depending...

Страница 14: ...ON DIP 10 Initial operation Initial operation varies for the two HMS 100 and FHZ 1000 systems Please make sure you read the following subsections a Setting the house code for the smoke detector You o...

Страница 15: ...fkt appears on the display Keep the PROG button pressed until Ext Alarm Ext Alarm Ext Alarm Ext Alarm Ext Alarm appears on the display of the FHZ 1000 Use the scroller to set the house code that you p...

Страница 16: ...n the ON position for this function to work 1 2 3 4 5 ON DIP HMS 100 function on If you do not intend to operate the smoke detector as part of the HMS 100 system you can use DIP switch 5 to switch off...

Страница 17: ...display Use the scroller or the x and w buttons to select the Sensor einstellen Sensor einstellen Sensor einstellen Sensor einstellen Sensor einstellen menu item Press the OK button Sensor hinzuf gen...

Страница 18: ...ion 10 d Insert three new AA batteries LR06 Conrad item no 650117 for example into the three battery holders making sure that the polarity is correct Useful figures are located in the battery compartm...

Страница 19: ...lauts digits space characters at the cursor position Then select the next position using the x and w buttons and repeat the procedure until you have entered the complete name You can also use the x an...

Страница 20: ...detector s smoke chamber A triggered alarm is signalised by an acoustic and an optical signal about every second The alarm is automatically terminated after 48 seconds once the smoke alarm s electroni...

Страница 21: ...lay to optically indicate that an alarm has been triggered d Periodic monitoring and error display You can find an overview of the smoke detector s optical and acoustic output in section 18 You should...

Страница 22: ...replacing the batteries if the smoke detector is part of a HMS 100 radio system the central unit stores the battery level as a fault St rung Note that the HMS 100 Z should first be set to the maintena...

Страница 23: ...lar rigid installation cable A total cable length of up to 400m is feasible in the ideal case You can connect up to 40 smoke detectors of the type RM 100 with one another via cable in the case of a ra...

Страница 24: ...24 Observe the correct polarity Cable terminal Installation of cable in the de vice when using radio modules Avoid contacting the cable with the antenna loop on the circuit board...

Страница 25: ...e the cables through the opening of the module cover plate and then outwards When placing the smoke detector on the lower plate make sure that the cables are not clamped while sealing Any additional c...

Страница 26: ...f a radio or a remote control for example When using an important device such as a smoke detector however this could have fatal consequences For this reason the smoke detector emits a short alarm sign...

Страница 27: ...ress the OK button Use the scroller or the x or w buttons to select the Sensor warten Sensor warten Sensor warten Sensor warten Sensor warten menu item Press the OK button Now you can use the x or w b...

Страница 28: ...o use any remaining capacity of the batteries in noncritical devices such as radios clocks and so on Insert three new AA batteries LR06 making sure that the polarity is correct plus and minus Useful d...

Страница 29: ...Once the central unit has received the sensor s new address it transmits the following notification Sensor x xx Sensor x xx Sensor x xx Sensor x xx Sensor x xx x old address for example 01 xx old nam...

Страница 30: ...oyed by the fire By doing this you waste the few seconds or minutes that could save lives Simply make copies of important documents personal ID driver s licence and so on You can use a conventional co...

Страница 31: ...rs are not familiar with it or they do not know what they should do when a fire alarm sounds Organise a family meeting in order to discuss the escape plan Explain to each person what they should do in...

Страница 32: ...stallation location and the environment As a rule when mounted in a family home for example the smoke detector should work properly and there should be no radio reception problems Other causes of redu...

Страница 33: ...es As the consumer you are legally obliged to return all your used batteries and rechargeable batteries Do not dispose of your used batteries via the household rubbish Batteries rechargeable batteries...

Страница 34: ...oustic signal tone white LED indicator short signal tone 3 short tones every 4 seconds white LED indicator is activated 3 short tones every 4 seconds white LED indicator is activated short signal tone...

Страница 35: ...C Relative humidity 5 to 93 non condensing Internal signal transmitter 85dB A 3m Dimensions dia x H 120mm x 44mm Max cable length for cable connection 400m J Y St Y2 x 2 x 0 6mm Max no of devices for...

Страница 36: ...s permitted in whole or part e g photocopy microfilmingorstorageinelectronicdataprocessingequipment without the express written consent of the publisher The operating instructions reflect the current...