V10A SPECIFICATIONS
Line Level Section:
Gain: 18 dB
Maximum Output: 20V
Hum and noise: 92 dB below 2.5V output
Distortion: less than .1% THD or IMD
Phase: line section inverts phase of all inputs (including phono) at
main out
Output impedance: less than 800 ohms
Phono Section: Applies only to PV10A with phono stage.
Gain: 48.5 dB (to tape out)
Overload: in excess of 125 mv at 1kHz
Phase: phono stage is phase correct (at tape out).
RIAA Equalization: +/- .25dB (20Hz-20KHz)
Hum and noise(20Hz-20KHz): 75 dB below 10mv input
Mechanical:
Dimensions: 15.75"W x 3.75"H x 11"D
Weight: 12 lbs.
Fuse
The power transformer of the PV10A is protected by a fuse on the ac
power line (mains). A failure of this fuses is a symptom of a more serious
problem, and a competent service technician should be consulted. The
fuse is located on the printed circuit board, near the transformer.
In no
event should the fuse be replaced with a value or type different
than that originally supplied. The correct fuse value is:
PV10A (with phono):
100 or 120V AC 3/4 amp, slow blow
220 or 240V AC 1/2 amp, slow blow
PV10AL (line stage only):
100 or 120V AC 1/2 amp, slow blow
220 or 240V AC 1/4 amp, slow blow