background image

-1

FOX-2003SJ-1

-1

5A250V

(COMP, Defrost), 5A(FAN)

Heater

ON

Read carefully this instruction manual before use and use 
the product properly.
   The specifications, appearance and dimension may be changed
for improvement of performance without a prior notice

WARNING

1. This product is not made as a safety device, so when it is used for
    a control of devices feared to cause casualties, damages to the
    peripheral devices or huge property loss, the double safety 
    devices should be arranged before use.
2. Avoid connecting lines, checking and repairing the products while
    power is supplied.

3. Connect power after making sure the terminal number.
4. Never disassemble modify, improve or repair the product.

CAUTIONS

Be well-informed of how to use, safety regulations, warnings, etc
before installation of this device and apply it to the extent of the defined 
specifications and relevant capacity without fail.

Avoid wiring or installation to a motor or solenoid with a large inductive load.

Use a shiled cable for extention of the sensor and ensure not to make it longer
than the necessity.

Ensure not to use the parts generating arc when switching at the same power
source or near to it.
Keep the power cable away from a high-tention power line and ensure not to
install it at a place with serious oil and dirt.
Avoid strong magnetic field or serious noise, vibration or impact.
Keep away from the place where strong alkaline or acid material is directly 
released and use an independent pipe line.
When it is installed at kitchen, ensure not to pour water directly over the product 
for cleaning.

Keep the sensor cable away from signal line, power source, power line or
loaded line and use an independent pipe line.
Note that the mark of         in terminal connection diagram is the safety 
expression for warnings or cautions. 

Avoid using the product close to the device generating noises(high frequency
welder, high frequency sewing machine, high frequency radio, large capacity
SCR Controller, etc).
The use in any way other than what is instructed by the manufacturer may 
cause injury or property loss.
It is not a toy and keep it out of reach of children’s hand.
The installation of the device should be performed by an expert or a qualified
personnel without fail.
We shall not take any responsibility for the damage caused by non-compliance
with the above-mentioned warnings or cautions or by any consumer’s mistake.

Power 

Operating machine
         (load)

Example for connection of relay

Relay contact
output terminal

DANGER

Electric shock -Do not touch AC terminal during application of 
electric current. It may cause electric shock.
Cut the power supply without fail during checking the input power.

Model

DEFROST

DEFROST

(Cooler only)

Functions

Temp. Range

Relay contact

Sensor

Controlled output

control

Defrost control

control

ON

Defrost

FAN

Heater

Down switch

Function changing switch

UP switch

Defrost switch

Setting Temperature

By pressing this key, the set value is flickered.

Displays the present temperature

flickering the

setting temp.

By pressing this key, the set value is changed.

setting temp.
change

After changing 
of the set value

press this key.

Setting value saving confirmed Letter(O-K) 
is displayed, then present temperature.

setting confirm.
letter O-K

present temp.

Program Setting

   

 

setting

after defrost

FAN ON delay

time setting

low temp.

stoppage

deviation

setting

COMP cumulative

time defrost

selection

How to change the setting temp. for M ain output

If press it once, the setting value is flickered        .

or

the value can be up &  down with these keys.

A key to enter to installer mode if press for more than 5 sec,

How to set mode function for installer

change with these keys.

Relay contact capacity is less than 250VAC 2A.

If using the load to exceed contact capacity,

be cautious on those can be caused by 

contact deposited, contact failure, relay damaged,etc.

Version  0.91(2016.12.27)

www.conotec.co.kr

2A250V

AC LINE

set to 

defrost

time

setting

RESET

Exisiting

setting

PV

Rebooting-->display
the model name
-->display PV

set to 

defrost

OFF time

temp. correction

(correction the

 differential

 between the 

 indicated value

 and real value)

output delay

time setting

hysteresys

(deviation)

temp.setting

selection

To be reset after 
initialized 
except of 

press for more than 5 seconds.

-1

COMP output display
Defrost output display
FAN output display
Heater/LTS
(low temp. stop) display

Defrost

ON

FAN

Отзывы: