Connerton A-1F Скачать руководство пользователя страница 12

LIMITED

 

WARRANTY

The

 

Connerton

 

warrants

 

to

 

the

 

original

 

user

 

for

 

a

 

period

 

of

 

one

 

year

 

from

 

date

 

of

 

installation,

 

not

 

to

 

exceed

 

18

 

months

 

from

 

date

 

of

 

shipment

 

by

 

Connerton,

 

that

 

the

 

equipment

 

manufactured

 

is

 

free

 

from

 

defects

 

in

 

material

 

or

 

workmanship.

Our

 

obligation

 

under

 

this

 

warranty

 

shall

 

be

 

limited

 

to

 

furnishing

 

without

 

charge

 

any

 

part

 

of

 

said

 

product

 

which,

 

upon

 

examination

 

by

 

The

 

Connerton

 

shall

 

prove

 

to

 

be

 

defective.

 

Parts

 

wear

 

is

 

not

 

considered

 

a

 

defect.

 

The

 

Connerton

 

will

 

not

 

be

 

responsible

 

for

 

labor

 

or

 

transportation

 

charges

 

incidental

 

to

 

the

 

replacement

 

of

 

same.

The

 

Connerton

 

assumes

 

no

 

responsibility

 

for

 

failure

 

of

 

the

 

equipment

 

to

 

operate

 

properly

 

due

 

to

 

improper

 

installation

 

or

 

operation.

 

This

 

warranty

 

applies

 

to

 

all

 

equipment

 

that

 

has

 

been

 

unaltered,

 

properly

 

installed

 

and

 

maintained

 

in

 

accordance

 

with

 

national

 

and

 

local

 

codes

 

and

 

in

 

accordance

 

with

 

the

 

installation

 

and

 

operating

 

instructions

 

included

 

with

 

this

 

equipment.

This

 

warranty

 

does

 

not

 

extend

 

to

 

normal

 

maintenance

 

items,

 

including

 

but

 

not

 

limited

 

to,

 

thermostatic

 

calibrations,

 

air

 

and

 

gas

 

adjustments

 

and

 

adjustments

 

to

 

pilot

 

flames.

 

Proper

 

installation,

 

adjustments,

 

calibration

 

and

 

initial

 

checkout

 

is

 

the

 

responsibility

 

of

 

the

 

dealer,

 

the

 

owner-user

 

or

 

installer

 

and

 

not

 

that

 

of

 

The

 

Connerton.

Exceptions

 

to

 

warranty:

1)

 

Flexible

 

gas

 

connectors

 

that

 

are

 

bent

 

or

 

twisted

 

due

 

to

 

improper

 

installation

 

or

 

operation

 

and/or

 

modifying

 

the

 

location

 

of

 

fittings

 

that

 

the

 

tube

 

is

 

connected

 

to.

Please fill out and refer to the following when contacting the factory:

Model # A-1F

Serial#

Gas Type:

Purchase Date:

TROUBLESHOOTING GUIDE (cont.)

Bottom drawer hard to

Spring tension too tight

Loosen spring adjustment rod until

Push to down position

drawer can be pushed down with one
finger.

Top griddle not level

Broiler has not been

Adjust bullet feet inserts until broiler

setup properly.

is level from side to side, and from
front to rear.

Condition

Probable Cause

Solution

Bottom drawer does not

Detent setup

Clean detent plate depressions, ball

remain in middle positions

bearings and springs. Replace with
new parts if necessary.

Bottom griddle not level

Leveling rod setting

Adjust left and right side rods evenly,
top nut first then bottom nut, until
pitch drops 1/8” in rear.

Содержание A-1F

Страница 1: ...ivery agency immediately RETAIN THIS MANUAL FOR FUTURE USE 1 Preparation For Installation Z223 1 Initial setup must be made by a licensed service company Safe and satisfactory operation of the broiler...

Страница 2: ...P gasses For proper performance the broiler must be level Adjusting feet are provided at the bottom of the legs Carefully level the broiler using bubble type level on top plate If the broiler is suppl...

Страница 3: ...ove front bolt from bar on inner track that assembly rolls on Pull inner track out to rear stop bolt Lift off broiling griddle from drawer Lift out broiler drawer through slots cut in inner track Clea...

Страница 4: ...nto burner aligning holes in the top of the radiant with the tabs extending from the burner Check radiant to make sure that it is centered and resting on top of the burner held in position by the tabs...

Страница 5: ...the product thus compromising quality Do not use corrosive cleaning agents on the grill They may appear to work well on the top of the grill surfaces but they also destroy the interior walls of the g...

Страница 6: ...creasing spring tension To decrease spring tension loosen the nuts NOTE Make equal adjustments to BOTH springs to prevent unbalanced tension Checking the Detent Assembly The detent assembly regulates...

Страница 7: ...und on the main gas manifold at the base of the unit Top Burners Clean top burners using the following steps 1 Scrub thoroughly with a wire brush 2 Use a 49 drill or drill sized as close as possible w...

Страница 8: ...iner 18 L Removable Side Liner left 18 R Removable Side Liner right 21 Flexible Gas Connector 22 Track Support 22 A Grease Deflector 23 Grease Pan 5 A Manifold Air Mixer 24 B Manual Valve mpt x cc 24...

Страница 9: ...Bearings 34 Bottom Burner 34 B Air Shutter 35 Bottom Pilot 35 B Tubing for Bottom Pilot 36 Bottom Carryover Orifice 37 Bottom Griddle Support Frame 38 Support Frame Leveling Rod 39 Axis Shaft 40 Sprin...

Страница 10: ...e connector is attached The connector is provided with hex shaped fittings on each end Fitting A should be held firmly with a wrench and not allowed to turn while a second wrench is used to tighten fi...

Страница 11: ...ice No bottom burner flame Thermostat Check calibration and by pass setting recalibrate or replace Top griddle too hot Insulation board failing Replace insulation board Top burners set full open Chang...

Страница 12: ...not limited to thermostatic calibrations air and gas adjustments and adjustments to pilot flames Proper installation adjustments calibration and initial checkout is the responsibility of the dealer t...