Chapter 4
Installing the Drive
Page 28
Filepro CFP2105 Series
Installing a CFP2105E
The following paragraphs describe the installation procedure for a 16-bit Single
Connector Attachment (SCA) interface, model CFP2105E drive.
Setting the Drive's Jumpers - CFP2105E
There are no jumpers to set on the model CFP2105E and CFP1007E drives since
all the necessary control signals are on the SCA connector. This drive is
intended for applications where the drive is configured at the interface when the
drive is plugged into the interface connector.
Setting the SCSI Bus Address - CFP2105E
The SCSI bus ID of the drive is set by grounding the Interface bus signals shown
below in Table 4-4.
Table 4-4
Setting the SCSI ID
SCSI ID
SCSI ID(0)
SCSI ID(1)
SCSI ID(2)
SCSI ID(3)
0
Open
Open
Open
Open
1
Ground
Open
Open
Open
2
Open
Ground
Open
Open
3
Ground
Ground
Open
Open
4
Open
Open
Ground
Open
5
Ground
Open
Ground
Open
6
Open
Ground
Ground
Open
7
Ground
Ground
Ground
Open
8
Open
Open
Open
Ground
9
Ground
Open
Open
Ground
10
Open
Ground
Open
Ground
11
Ground
Ground
Open
Ground
12
Open
Open
Ground
Ground
13
Ground
Open
Ground
Ground
14
Open
Ground
Ground
Ground
15
Ground
Ground
Ground
Ground
Содержание CFP2105 series
Страница 2: ......
Страница 16: ...Chapter 1 Overview of the Drives Page 8 Filepro CFP2105 Series...
Страница 28: ...Chapter 2 Specifications Page 20 Filepro CFP2105 Series...
Страница 60: ...Chapter 4 Installing the Drive Page 52 Filepro CFP2105 Series...
Страница 79: ...SCSI Physical Characteristics Chapter 5 Technical Reference Manual Page 71...
Страница 80: ......