Connected IO Inc., CONFIDENTIAL
7
CIO Router: ER2500T-XX-CAT1 User Manual
Revision: 4.0
Power LED, Yellow: Power is connected/Off: unit is off
Cellcular Connection Strenght Indicators, Green: Cellcular
Connection
The following table lists the signal strength range corresponding to
the number of LEDs lit:
5-LEDs On: > -61dBm
4-LEDs On: -63 dBm to -71 dBm
3-LEDs On: -73 dBm to -83 dBm
2-LEDs On: -85 dBm to -98 dBm
1-LED On: -97 dBm to -107 dBm
No-LEDs: < -109 dBm
2.2.
Radio Configurations
Model Name
LTE Band (MHz)
3G (MHz)
WiFi
ER2500T-NA-CAT1
B2: 1900 PCS
B4: 1700/2100 AWS 1
B5: 850
B12: 700 ac
B13: 700 c
B2: 1900
B5: 850
Yes, 802.11 b/g/n
compliant
ER2500T-VZ-CAT1
B2: 1900 PCS
B4: 1700/2100 AWS 1
B13: 700 c
No Fallback
Yes, 802.11 b/g/n
compliant
3.
System Configuration
3.1.
Initial IP Setup
The Router Management GUI can be accessed through the Ethernet ports with the default IP address of
192.168.71.1
.
To configure The Router, follow the following sequence:
•
Connect the Ethernet cable between the
computer and The Router LAN port
•
Setup the
desktop as a static IP in
192.168.71.
x
domain or DHCP client to get IP from The Router
•
Open a browser and type http://
192.199.71.1
to start the settings
On login page, you can just click the Login icon to enter the GUI as shown in Figure 1. Default password
is
“
password
”
, it is recommended that a new password be created under Web GUI
System->Administration page.