Connect Tech Xtreme Xtreme/PSU-UC User Manual
Revision 0.00
15
Turn Supply OFF
Connecting the SHUTDOWN# pin to ground the Xtreme/PSU-UC’ +5V and +12V will turn OFF.
Alternatively the Xtreme/PSU-UC can be turned OFF by driving the SHUTDOWN# pin to a voltage below
+1.3V.
Connection Example A - Mechanical Switch Method
Connection Example B - External I/O Control Method