background image

 

 

Contents   

 

 

 

 

 

 

 

 

 

 

DFlex-4/104 User's Manual, ver. 0.04 

Table of Contents 

 

Chapter 1: Introduction

 

Introduction.................................................................................1-1 
Manual Overview........................................................................1-1 

Conventions & Symbols.....................................................1-2 

Product Overview .......................................................................1-3 

DFlex-4/104 Adapter..........................................................1-3 
DFlex-4/104 Software ........................................................1-6 

Customer Service Overview .......................................................1-6 
RMA Overview...........................................................................1-9 

 

Chapter 2: Hardware Installation

 

Introduction.................................................................................2-1 
Configuration ..............................................................................2-1 

Port Addresses....................................................................2-2 

Status Port Addresses ................................................2-3 
Custom Port Addresses..............................................2-4 

Interrupt Selection ..............................................................2-6 

Mode 1 (one IRQ)......................................................2-7 
Mode 2 (two IRQs)....................................................2-9 
Mode 3 (four IRQs) .................................................2-11 

Baud Rate Selection .........................................................2-12 
Serial Line Interface Modules (SLIM).............................2-15 

SLIM Installation.....................................................2-15 
SLIM compatibility .................................................2-18 

Installing the DFlex-4/104 Adapter in your System ........2-18 

 

Chapter 3: Software Installation 

Introduction.................................................................................3-1 
Configuration ..............................................................................3-1 

DOS 3.XX - 6.XX ..............................................................3-1 
Linux...................................................................................3-2 
Multiuser DOS 7 GOLD ....................................................3-2 
OS/2....................................................................................3-2 
QNX 2.XX..........................................................................3-2 
QNX 4.XX..........................................................................3-3 
SCO Unix ...........................................................................3-3 
Windows 3.XX...................................................................3-3 
Windows 95/98...................................................................3-3 
Windows NT ......................................................................3-4 

Utilities........................................................................................3-4 

Portfind ...............................................................................3-4 
Porttest................................................................................3-4 
SeePORT ............................................................................3-4 

Содержание DFlex-4/104

Страница 1: ... Multi port Serial Communications Adapter User Manual Connect Tech Inc 42 Arrow Road Guelph Ontario N1K 1S6 Tel 519 836 1291 1 800 426 8979 Fax 519 836 4878 Email sales connecttech com FTP ftp connecttech com URL http www connecttech com CTIM 00144 Revision 0 04 February 26 2001 Part Number MAN045 ...

Страница 2: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 3: ... been subjected to abuse misuse accident disaster or non Connect Tech Inc authorized modification or repair You may obtain Limited Warranty service by delivering this product to an authorized Connect Tech dealer or to Connect Tech Inc along with proof of purchase If this product is shipped you agree to insure the product or assume risk of loss or damage in transit and to prepay shipping charges to...

Страница 4: ...hts are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Connect Tech Inc Copyright 1987 1988 1989 1990 1996 1997 1998 1999 and 2001 by Connect Tech Inc Trademark Acknowledgment Connect Tech Inc acknowledges all trademarks registered trademarks and or copyrights referred to in this document as the property of the...

Страница 5: ... Manual ver 0 04 Certification DFlex 4 104 The DFlex 4 104 is to be included into a device ultimately subject to FCC DOC IC and CE certification The customer is responsible for bringing the completed device into compliance prior to resale ...

Страница 6: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 7: ...t Addresses 2 3 Custom Port Addresses 2 4 Interrupt Selection 2 6 Mode 1 one IRQ 2 7 Mode 2 two IRQs 2 9 Mode 3 four IRQs 2 11 Baud Rate Selection 2 12 Serial Line Interface Modules SLIM 2 15 SLIM Installation 2 15 SLIM compatibility 2 18 Installing the DFlex 4 104 Adapter in your System 2 18 Chapter 3 Software Installation Introduction 3 1 Configuration 3 1 DOS 3 XX 6 XX 3 1 Linux 3 2 Multiuser D...

Страница 8: ...ower Connector Pinouts 4 5 SLIM Pinouts 4 6 Appendix C Factory Settings 4 7 I O Status Port Address Setting 4 7 IRQ Setting 4 8 Baud Rate Setting 4 9 Appendix D SLIM Insertion Removal 4 11 SLIM insertion 4 11 SLIM removal 4 12 Appendix E RS 232 SLIM Option 4 13 Installation 4 15 Appendix F RS 485 422 Options 4 17 Installation 4 17 RS 485 422 SLIM 4 18 RS 485 422 Cable Wiring 4 21 Appendix G RS 423...

Страница 9: ...SW1 2 4 Figure 5 IRQ jumper switch blocks 2 6 Figure 6 Baud rate jumper block J1 2 13 Figure 7 SLIM socket to serial port relationship 2 16 Figure 8 I O Status port address factory settings 4 7 Figure 9 IRQ factory setting 4 8 Figure 10 Baud rate factory setting J1 4 9 Figure 11 SLIM insertion 4 11 Figure 12 SLIM removal 4 12 Figure 13 RS 232 RS 232 Fast SLIM partial schematic 4 14 Figure 14 RS 48...

Страница 10: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 11: ...s Manual ver 0 04 Chapter 1 Introduction Introduction 1 1 Manual Overview 1 1 Conventions Symbols 1 2 Product Overview 1 3 DFlex 4 104 Adapter 1 3 DFlex 4 104 Software 1 6 Customer Service Overview 1 6 RMA Overview 1 9 ...

Страница 12: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 13: ...nnect Tech products Manual Overview The purpose of the DFlex 4 104 User s Manual is to help you install the DFlex 4 104 as effortlessly as possible The manual includes four main sections Introduction the section you are currently reading covers the DFlex 4 104 features Connect Tech s customer services and return merchandise authorization RMA policies and procedures Hardware Installation describes ...

Страница 14: ...ns or special cases Example the Example convention outlines hardware and software installation examples Technical Tip the Technical Tip convention offers technical tips to assist you in hardware and software installation or problems WARNING The Warning convention advises you to take certain precautions in order to avoid possible damage to your Connect Tech product This message warns you that your ...

Страница 15: ...ces Electrical interfaces are on Serial Line Interface Modules SLIM and are field upgradeable multiple DFlex 4 104 adapters may reside in a system 16C654 quad UARTs are used to control each port The 16C654 quad UART has 64 byte transmit and receive FIFO for each port and automatic software hardware flow control each port has independent baud rate selection offering baud rates from 50 460 8 KBPS wi...

Страница 16: ...ctors SLIM sockets Quad UART Power connector PC 104 bus connector IRQ jumper block J2 9 2 10 Maximum baud rate jumper block J1 11 Port IRQ address switch block SW1 The DFlex 4 104 adapters can accommodate both small and large multi channel applications You can combine DFlex 4 104 adapters in a single system Figure 2 below represents a sample configuration for a system requiring 16 ports ...

Страница 17: ...5 DFlex 4 104 User s Manual ver 0 04 Figure 2 DFlex 4 104 16 port configuration Host System Terminals Terminals Terminals Terminals DFlex 4 104 DFlex 4 104 DFlex 4 104 DFlex 4 104 9 2 1 0 1 1 9 2 1 0 1 1 9 2 1 0 1 1 9 2 1 0 1 1 ...

Страница 18: ...ience difficulties after reading the manual and using the product contact the Connect Tech reseller from which you purchased the product In most cases the reseller can help you with product installation and difficulties In the event that the reseller is unable to resolve your problem our highly qualified support staff can assist you Please refer to and complete the problem summary sheet found in F...

Страница 19: ...No of serial ports IRQ selected Base address selected I O port address selected Device driver Revision no System Description Operating system Revision no System type manufacturer Amount of RAM CPU type speed Video adapter Settings Network adapter Settings Hard disk adapter Settings Tape adapter Settings Other serial adapters Settings Other adapters Settings Devices connected to ports ...

Страница 20: ...r Internet email address OR 2 You can refer to our knowledge database found in the Customer Support section of our World Wide Web site OR 3 You can fill out the problem summary form found in the Customer Support section of our World Wide Web site and submit it to our customer support engineers via the Web OR 4 You can obtain the latest versions of software drivers and manuals from the Customer Sup...

Страница 21: ...iption of the problem and the RMA number Clearly display the RMA number on the external packaging Please refer to the Limited Warranty for further restrictions or requirements Your DFlex adapter is very sensitive to static electricity Make sure that before you remove the card from your computer you wear an anti static wristband When you remove the board from your computer handle it only by the edg...

Страница 22: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 23: ...esses 2 2 Status Port Addresses 2 3 Custom Port Addresses 2 4 Interrupt Selection 2 6 Mode 1 one IRQ 2 7 Mode 2 two IRQs 2 9 Mode 3 four IRQs 2 11 Baud Rate Selection 2 12 Serial Line Interface Modules SLIM 2 15 SLIM Installation 2 15 SLIM compatibility 2 18 Installing the DFlex 4 104 Adapter in your System 2 18 ...

Страница 24: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 25: ...your DFlex 4 104 adapter in your system In order to insure a successful installation please follow the steps in the order specified below 1 Selection of I O and status port addresses 2 Selection of IRQs 3 Baud rate selection 4 Serial Line Interface Module SLIM options 5 Installation of Serial Line Interface Modules SLIM 6 Configuration of RS 232 and or RS 485 422 and or RS 423 and or Current Loop ...

Страница 26: ...puter s I O address space In most cases the factory setting is sufficient but when there is a conflict SW1 may require a different setting Table 1 summarizes typical I O port address usage WARNING Do not use a pencil to set the DIP switches as the lead graphite may short circuit the switch Table 1 Typical port address usage Port Address Hex Usage 000 0FF Reserved 170 177 Fixed disk controller prim...

Страница 27: ...enabled and disabled using DIP switch 6 on switch block SW1 When DIP switch 6 is in the on position the status port is enabled and when it is in the off position it is disabled Please refer to Table 2 for a list of supported status port addresses and to Figure 4 for a description and location of switch block SW1 Technical tip You should set DIP switch 6 on switch block SW1 to the off position if y...

Страница 28: ...resses by making changes to the PALs found on the DFlex 4 104 adapter If you require specific port addresses not listed in Table 2 please contact the Connect Tech sales department for further information Figure 4 Port address SW1 Port address switch block 9 2 10 11 4 5 SW1 ON 1 2 3 6 Port address switches Status Port switch ...

Страница 29: ...xample shows the port address jumper block set for the factory setting of port addreses 200 208 210 218 hex and status port disabled Port address switch block 4 5 SW1 ON 1 2 3 6 Port address switches Status Port switch 2 The following example shows the port address jumper block set for port addreses 2F8 3F8 340 348 hex and status port disabled Port address switch block 4 5 SW1 ON 1 2 3 6 Port addr...

Страница 30: ...ock J2 and DIP switches 4 and 5 on switch block SW1 situated near the PC 104 bus connector on the DFlex 4 104 adapter Please refer to Figure 5 for a description and location of the jumper block J2 and switch block SW1 Figure 5 IRQ jumper switch blocks IRQ jumper block 3 5 7 9 2 4 6 10 12 14 15 11 9 2 10 11 B A D C J2 IRQ IRQ switches ON 1 2 6 SW1 Off 3 5 4 ...

Страница 31: ...each port interrupts on it s own interrupt Mode 1 one IRQ Mode 1 allows you to select one IRQ for all ports This mode is recommended for most installations Please follow these steps to choose this mode 1 Choose an available IRQ you wish the ports to interrupt on 2 Make sure that switch block SW1 has DIP switches 4 and 5 in the off position 3 Install a jumper across the corresponding IRQ pins on th...

Страница 32: ...5 7 9 2 4 6 10 12 14 15 11 B A D C J2 IRQ Port address switch block ON 1 2 6 SW1 3 4 IRQ switches 5 Off 2 The following example shows the settings on J2 and SW1 so that all ports will interrupt on IRQ 10 IRQ jumper block 3 5 7 9 2 4 6 10 12 14 15 11 B A D C J2 IRQ Port address switch block ON 1 2 6 SW1 3 4 IRQ switches 5 Off Note Ensure that all other unused jumpers on J2 are removed or not contac...

Страница 33: ...le interrupt for ports 2 and 4 2 Make sure that switch block SW1 has DIP switch 4 in the on position and DIP switch 5 in the off position 3 Install a jumper across the corresponding IRQ pins on the A C row and the middle row of jumper block J2 for ports 1 and 3 Then install a jumper across the corresponding IRQ pins on the B D row and the middle row of jumper block J2 for ports 2 and 4 4 Ensure th...

Страница 34: ... 10 12 14 15 11 B A D C J2 IRQ Port address switch block ON 1 2 6 SW1 Off 3 4 IRQ switches 5 2 The following example shows the settings on J2 and SW1so that ports 1 and 3 will interrupt on IRQ 10 and ports 2 and 4 will interrupt on IRQ 15 IRQ jumper block 3 5 7 9 2 4 6 10 12 14 15 11 B A D C J2 IRQ Port address switch block ON 1 2 6 SW1 Off 3 4 IRQ switches 5 Note Ensure that all other unused jump...

Страница 35: ...ins 4 First install a jumper across an IRQ pin on the A portion of J2 and the corresponding pin in the middle row of J2 for port 1 5 Next install a jumper across an IRQ pin on the B portion of J2 and the corresponding pin in the middle row of J2 for port 2 6 Then install a jumper across an IRQ pin on the C portion of J2 and the corresponding pin in the middle row of J2 for port 3 7 Finally install...

Страница 36: ... SW1so that port 1 interrupts on IRQ 5 port 2 interrupts on IRQ 7 port 3 interrupts on IRQ 12 and port 4 interupts on IRQ 15 IRQ jumper block 3 5 7 9 2 4 6 10 12 14 15 11 B A D C J2 IRQ Port address switch block ON 1 2 6 SW1 Off 3 4 IRQ switches 5 Note Ensure that all other unused jumpers on J2 are removed or not contacting more than one pin Baud Rate Selection The DFlex 4 104 is a high speed seri...

Страница 37: ...f jumper J1 If the jumper is in the off position default during a hardware reset the maximum baud rate will be 115 2 kbps However if the jumper is in the on position during a hardware reset the maximum baud rate will be 460 8 kbps Please refer to Figure 6 for a description and location of the jumper block J1 Figure 6 Baud rate jumper block J1 Baud rate jumper block J1 Off 115K J1 On 460K 9 2 10 11...

Страница 38: ...evice drivers actually autodetect or allow the user to specify the oscillator frequency in order to select the desired baud rate correctly The Connect Tech Windows95 driver Control Panel Applet has a selection for DFlex Fast or DFlex 4 104 Manual The OS2 driver from Ray Gwinn SIO autodetects the oscillator Automatic The QNX4 driver Dev ctiser allows the user to specify what divisor to use Selected...

Страница 39: ...odules please refer to Appendix G RS 423 Option for more technical information If you order 20mA current loop modules please refer to Appendix H 20mA Current Loop Option for more technical information SLIM Installation The DFlex 4 104 adapter has two sockets that accept Serial Line Interface Modules SLIM Each SLIM provides the RS 232 or RS 485 422 or RS 423 or 20mA current loop receivers and trans...

Страница 40: ...ese steps 1 Place the SLIM into the socket almost vertically about a 75 degree angle making sure to align it properly before inserting it into the socket 2 Press downward and sideways on the SLIM until it latches into the socket Do NOT force the SLIM the installation process requires a small amount of force and should be very smooth and easy If you experience resistance check the alignment and ins...

Страница 41: ... 104 adapter The force required to open the clips is small and the SLIM naturally springs upwards when the clips are open wide enough If removal is difficult then you are probably trying to raise the SLIM before the clips are open Refer to Appendix D SLIM Insertion Removal regarding the removal of a SLIM The RS 232 RS 232 Fast RS 485 422 RS 423 and 20mA current loop SLIMs are very sensitive to sta...

Страница 42: ...w these steps Computer components are very sensitive to static electricity When installing adapters in your computer make sure that you wear an anti static wristband Handle the adapter by its edges and place it on the anti static bag or an anti static mat 1 Turn the power off to your system 2 Open your system to expose the PC 104 bus connector consult the system documentation for information on th...

Страница 43: ...re Installation Introduction 3 1 Configuration 3 1 DOS 3 XX 6 XX 3 1 Linux 3 2 Multiuser DOS 7 GOLD 3 2 OS 2 3 2 QNX 2 XX 3 2 QNX 4 XX 3 3 SCO Unix 3 3 Windows 3 XX 3 3 Windows 95 98 3 3 Windows NT 3 4 Utilities 3 4 Portfind 3 4 Porttest 3 4 SeePORT 3 4 ...

Страница 44: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 45: ...e notes concerning installation and configuration of various device drivers and software utilities If you require more information please contact Connect Tech Customer Service Configuration The following sections detail some recommended configurations for the DFlex 4 104 running under various operating systems These settings will depend on both the number of boards being installed and the existing...

Страница 46: ...ltiple serial ports sharing one IRQ Please refer to the MULTDOS7 TXT file on the DFlex 4 104 distribution diskette for more information about installing the DFlex 4 104 for the Multiuser DOS 7 GOLD operating system OS 2 OS 2 is a leading multi tasking operating system for Intel based personal computers Please contact Connect Tech Customer Support about installing the DFlex 4 104 for the OS 2 opera...

Страница 47: ...allow users to configure their computer systems with multiple serial ports sharing one IRQ Please contact Connect Tech Customer Support about installing the DFlex 4 104 for the SCO Unix operating system Windows 3 XX Windows 3 XX is a leading operating system for Intel based personal computers Please refer to the WIN31 TXT file on the DFlex 4 104 distribution diskette for more information about ins...

Страница 48: ... tests on the RxD TxD RTS CTS DTR and DCD signals of the serial ports in your system For more information on the use of Porttest please refer to the readme file porttest txt on the DFlex 4 104 distribution diskette SeePORT SeePORT is a full featured serial data analyzer included with Blue Heat PCI DFlex and DFlex 4 104 adapters This handy utility enables the user to examine the data associated wit...

Страница 49: ...onnector Pinouts 4 5 SLIM Pinouts 4 6 Appendix C Factory Settings 4 7 I O Status Port Address Setting 4 7 IRQ Setting 4 8 Baud Rate Setting 4 9 Appendix D SLIM Insertion Removal 4 11 SLIM insertion 4 11 SLIM removal 4 12 Appendix E RS 232 SLIM Option 4 13 Installation 4 15 Appendix F RS 485 422 Options 4 17 Installation 4 17 RS 485 422 SLIM 4 18 RS 485 422 Cable Wiring 4 21 Appendix G RS 423 Optio...

Страница 50: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 51: ...5 1 mA typ RS 232 Fast SLIM no load 5 VDC 5 30 mA typ 12 VDC 10 38 mA typ 12 VDC 10 36 mA typ RS 485 422 SLIM no load 5 VDC 5 120 mA typ RS 423 SLIM no load 5 VDC 5 70 mA typ 12 VDC 10 26 mA typ 12 VDC 10 26 mA typ 20mA Current loop SLIM no load 5 VDC 5 30 mA typ 12 VDC 5 4 mA typ PC Bus Interface PC interrupts are jumper selectable 2 3 4 5 6 7 9 10 11 12 14 15 Base address for I O ports is DIP sw...

Страница 52: ... D4104654XX DFlex 4 104 4 port c w 16C654 UARTs unpopulated D4104654NC DFlex 4 104 4 port c w 16C654 UARTs unpopulated no cable SIMM RS232 RS 232 SLIM module SIMM F232 RS 232 Fast SLIM module SIMM RS485 RS 485 SLIM module SIMM RS423 RS 423 SLIM module SIMM 20MA Current Loop SLIM module CAB104 DFlex 4 104 cable c w male DB9 connector Certification DFlex 4 104 The DFlex 4 104 is to be included into ...

Страница 53: ... Connector Pinouts Tables 4 shows the pinouts for the DFlex 4 104 10 pin port header connectors Table 4 10 pin port header pinouts Pin No RS 232 Signal RS 485 Signal RS 423 Signal Current Loop Signal 1 DCD RxD RxD RxD 2 N C CTS CTS RxD Return 3 RxD TxD TxD Ref TxD 4 RTS RTS RTS TxD 5 TxD TxD TxD TxD Source 6 CTS RTS RTS Ref RxD 7 DTR RxD RxD TxD Return 8 N C CTS CTS RxD Source 9 SG SR SR SG 10 5V ...

Страница 54: ...gnal RS 485 Signal RS 423 Signal Current Loop Signal 1 DCD RxD B RxD RxD 2 RxD TxD B TxD Ref TxD 3 TxD TxD A TxD TxD Source 4 DTR RxD A RxD TxD Return 5 SG SR SR SG 6 N C CTS A CTS RxD Return 7 RTS RTS A RTS TxD 8 CTS RTS B RTS Ref RxD 9 N C CTS B CTS RxD Source Male DB 9 Connector 1 5 6 9 Technical Tip Please ensure that you terminate the DCD or CTS signals if your application does not use them T...

Страница 55: ... User s Manual ver 0 04 Power Connector Pinouts Table 6 shows the pinouts for the DFlex 4 104 8 pin power header connector Table 6 Power connector pinouts Pin No Description 1 GND 2 5V 3 5V 4 12V 5 N C 6 12V 7 GND 8 5V 7 5 3 1 2 4 6 8 Printed circuit board ...

Страница 56: ... 1 TxD Return 1 8 N C CTS B 1 CTS B 1 RxD Source 1 9 DCD 1 RxD B 1 RxD B 1 RxD 1 10 RTS 2 RTS A 2 RTS 2 TxD 2 11 TxD 2 TxD A 2 TxD 2 TxD Source 2 12 CTS 2 RTS B 2 RTS Ref 2 RxD 2 13 RxD 2 TxD B 2 TxD Ref 2 TxD 2 14 N C CTS A 2 CTS A 2 RxD Return 2 15 DTR 2 RxD A 2 RxD A 2 TxD Return 2 16 N C CTS B 2 CTS B 2 RxD Source 2 17 DCD 2 RxD B 2 RxD B 2 RxD 2 18 Ground 19 12 V 20 12 V 21 5 V 22 DCD 2 Tied ...

Страница 57: ...us Port Address Setting Switch block S1 sets the I O and status port addresses for the DFlex 4 104 adapter Connect Tech ships the DFlex 4 104 adapter with S1 set for I O port addresses 200 208 210 218 hex and the status port disabled Figure 8 shows the location and factory setting of this jumper block Figure 8 I O Status port address factory settings Port address switch block 9 2 10 11 4 5 SW1 ON ...

Страница 58: ...ne for the DFlex 4 104 adapter Connect Tech ships the DFlex 4 104 with a shorting block installed across pins to set all ports to interrrupt on IRQ 4 Figure 9 shows the location and factory setting of jumper block J2 and switch block SW1 Figure 9 IRQ factory setting IRQ jumper block 3 5 7 9 2 4 6 10 12 14 15 11 9 2 10 11 B A D C J2 IRQ IRQ switches ON 1 2 6 SW1 Off 3 5 4 ...

Страница 59: ... block J1 sets the maximum baud rate for the DFlex 4 104 adapter Connect Tech ships the DFlex 4 104 set for a maximum baud rate of 115K baud Figure 10 shows the location and factory setting of jumper block J1 Figure 10 Baud rate factory setting J1 Baud rate jumper block J1 Off 115K J1 On 460K 9 2 10 11 ...

Страница 60: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 61: ...dules SLIM Figure 11 SLIM insertion Clip Peg Hole 1 2 1 Place the SLIM into the socket almost vertically about 75 degree angle making sure that it is properly oriented and fully inserted into the socket 2 Press downward and sideways on the SLIM until it latches into the socket Do NOT force the SLIM the installation process requires a small force and should be very smooth and easy If you encounter ...

Страница 62: ... hold the SLIM into the socket and place your index fingers on the edge of the SLIM 2 Push outwards with your thumbs on the clips until the SLIM is released from the clips Your index fingers can then raise the SLIM past the clips The SLIM is then free to be removed from the DFlex 4 104 board The force required to open the clips is small and the SLIM naturally springs upwards as soon as the clips a...

Страница 63: ...32 Fast SLIMs offer the following features The RS 232 electrical interface an industry standard that offers connection to a wide range of peripheral devices Each SLIM controls two ports SLIMS are field upgradeable providing you with more flexibility for your application WARNING You must insert Serial Line Interface Modules into all of the SLIM sockets to attain the communications functionality of ...

Страница 64: ... the RS 232 or RS 232 Fast SLIM Figure 13 RS 232 RS 232 Fast SLIM partial schematic UART RS 232 RS 232 Fast SLIM Partial Schematic DB9 Connector DTR RXD RTS 1 3 8 2 4 7 CTS TxD DCD 5 SG Note The RS 232 and RS 232 Fast Serial Line Interface Module controls two ports and therefore the schematic shows only a portion of the circuit ...

Страница 65: ...aces ports 1 and 2 SLIM 2 socket interfaces ports 3 and 4 Please refer to Chapter 2 Hardware Installation for the location of the SLIM sockets and to Appendix D SLIM Insertion Removal for the proper procedures to installing and removing SLIMs Your DFlex adapter and Serial Line Interface Module SLIM are very sensitive to static electricity Make sure that before you remove them from the anti static ...

Страница 66: ... 1 9 DCD 1 RxD B 1 RxD B 1 RxD 1 10 RTS 2 RTS A 2 RTS 2 TxD 2 11 TxD 2 TxD A 2 TxD 2 TxD Source 2 12 CTS 2 RTS B 2 RTS Ref 2 RxD 2 13 RxD 2 TxD B 2 TxD Ref 2 TxD 2 14 N C CTS A 2 CTS A 2 RxD Return 2 15 DTR 2 RxD A 2 RxD A 2 TxD Return 2 16 N C CTS B 2 CTS B 2 RxD Source 2 17 DCD 2 RxD B 2 RxD B 2 RxD 2 18 Ground 19 12 V 20 12 V 21 5 V 22 DCD 2 Tied high Tied high Tied high 23 CTS 2 Tied high 24 R...

Страница 67: ...ctionality of your DFlex 4 104 adapter Installation The DFlex 4 104 adapter has two SLIM sockets that accept Serial Line Interface Modules SLIM 1 socket interfaces ports 1 and 2 SLIM 2 socket interfaces ports 3 and 4 Please refer to Chapter 2 Hardware Installation for the location of the SLIM sockets and to Appendix D SLIM Insertion Removal for the proper procedures to installing and removing SLIM...

Страница 68: ...rted then the driver will be enabled only when RTS is asserted To disable the RS 485 line driver you must not assert DTR and RTS Also the receivers on the RS 485 SLIM are biased high through fixed resistors Please refer to Figure 14 for a partial schematic of the RS 485 422 SLIM circuit while Table 9 shows the pinouts for the SLIM sockets found on the DFlex 4 104 adapter Your DFlex 4 104 adapter i...

Страница 69: ...M Pin 31 SLIM Pin 28 SLIM Pin 32 SLIM Pin 33 SLIM Pin 3 SLIM Pin 5 SLIM Pin 2 SLIM Pin 7 SLIM Pin 9 SLIM Pin 6 SLIM Pin 8 SLIM Pin 21 SLIM Pin 18 SLIM Pin 4 NET 4 NET 3 RxD CTS DCD RxD B CTS B RxD A CTS A U1 U1 5 V Port 2 9 10 11 5 7 6 SLIM Pin 27 SLIM Pin 23 SLIM Pin 22 SLIM Pin 15 SLIM Pin 17 SLIM Pin 14 SLIM Pin 16 DTR U3 12 13 11 SLIM Pin 30 TxD RTS TxD A RTS A TxD B RTS B U2 U2 5 7 3 6 2 1 SL...

Страница 70: ...ce 1 9 DCD 1 RxD B 1 RxD B 1 RxD 1 10 RTS 2 RTS A 2 RTS 2 TxD 2 11 TxD 2 TxD A 2 TxD 2 TxD Source 2 12 CTS 2 RTS B 2 RTS Ref 2 RxD 2 13 RxD 2 TxD B 2 TxD Ref 2 TxD 2 14 N C CTS A 2 CTS A 2 RxD Return 2 15 DTR 2 RxD A 2 RxD A 2 TxD Return 2 16 N C CTS B 2 CTS B 2 RxD Source 2 17 DCD 2 RxD B 2 RxD B 2 RxD 2 18 Ground 19 12 V 20 12 V 21 5 V 22 DCD 2 Tied high Tied high Tied high 23 CTS 2 Tied high 24...

Страница 71: ...etween a port on the DFlex 4 104 adapter to a port on the RS 485 422 peripheral Figure 15 RS 485 422 wiring diagram 4 wire RTS RTS CTS CTS TxD TxD RxD RxD RxD TxD RxD TxD RTS CTS RTS CTS SR SR DFlex 4 104 adapter RS 485 peripheral 2 3 4 5 6 7 8 9 1 Figure 16 describes a 2 wire cabling scheme between a port on the DFlex 4 104 adapter to a port on the RS 485 422 peripheral Figure 16 RS 485 422 wirin...

Страница 72: ...DFlex 4 104 User s Manual ver 0 04 ...

Страница 73: ... Interface Modules into all of the SLIM sockets to attain the communications functionality of your DFlex 4 104 adapter Please refer to Figure 17 for a partial schematic of the RS 423 SLIM circuit Figure 17 RS 423 SLIM partial schematic UART RS 423 SLIM Partial Schematic DB9 Connector RxD RTS 1 3 9 4 8 7 CTS TxD TxD Ref 2 6 CTS RxD NET 2 NET 1 NET 1 NET 2 22K 22K 5V 22K 22K 5V RTS Ref 5 SR Note Not...

Страница 74: ...nd to Appendix D SLIM Insertion Removal for the proper procedures to installing and removing SLIMs Your DFlex 4 104 adapter and Serial Line Interface Module SLIM are very sensitive to static electricity Make sure that before you remove them from the anti static shipping bag you wear an anti static wrist band When you remove them from the anti static bag handle them only by the edges and place them...

Страница 75: ...e 1 9 DCD 1 RxD B 1 RxD B 1 RxD 1 10 RTS 2 RTS A 2 RTS 2 TxD 2 11 TxD 2 TxD A 2 TxD 2 TxD Source 2 12 CTS 2 RTS B 2 RTS Ref 2 RxD 2 13 RxD 2 TxD B 2 TxD Ref 2 TxD 2 14 N C CTS A 2 CTS A 2 RxD Return 2 15 DTR 2 RxD A 2 RxD A 2 TxD Return 2 16 N C CTS B 2 CTS B 2 RxD Source 2 17 DCD 2 RxD B 2 RxD B 2 RxD 2 18 Ground 19 12 V 20 12 V 21 5 V 22 DCD 2 Tied high Tied high Tied high 23 CTS 2 Tied high 24 ...

Страница 76: ...heme between a port on the DFlex 4 104 adapter to a port on the RS 423 peripheral Figure 18 RS 423 wiring diagram 4 wire SG CTS TxD RxD RxD RxD RxD TxD RTS CTS SR SR DFlex 4 104 adapter RS 423 peripheral 2 3 4 5 6 7 8 9 1 SR SG Figure 19 describes an all wire cabling scheme between a port on the DFlex 4 104 adapter to a port on the RS 423 peripheral Figure 19 RS 423 wiring diagram all wire SR CTS ...

Страница 77: ... 104 adapter Installation The DFlex 4 104 adapter has two SLIM sockets that accept Serial Line Interface Modules SLIM 1 socket interfaces ports 1 and 2 SLIM 2 socket interfaces ports 3 and 4 Please refer to Chapter 2 Hardware Installation for the location of the SLIM sockets and to Appendix D SLIM Insertion Removal for the proper procedures to installing and removing SLIMs Your DFlex 4 104 adapter...

Страница 78: ...ckard Optoelectronics Manual Catalogue for a complete description of HPCL 4100 and HPCL 4200 specifications Figure 20 20mA Current Loop SLIM schematic 33 Ohm 51 Ohm VF 1 5V 12V RxD SRC 12V RxD RET 2N2907A 22K 5V 5V 5V 3 TxD TxD 6 4 TxD HCPL 4100 5 8 HCPL 4200 8 5 6 RxD 7 1 RxD 2 RxD CTS DCD 33 Ohm 51 Ohm VF 1 5V 12V RxD SRC 12V RxD RET 2N2907A 22K 20mA Current Loop SLIM Partial Schematic Where SLI...

Страница 79: ...d passive modes When you use a current loop SLIM as a current source in the loop and the 20mA is flowing the corresponding LED on the Serial Line Interface Module will light If the loop is open or the current loop SLIM is not used as a current source the LED will be off WARNING When using the current source in a loop with low resistance the transistor will run hot This can be avoided by increasing...

Страница 80: ...rce 1 9 DCD 1 RxD B 1 RxD B 1 RxD 1 10 RTS 2 RTS A 2 RTS 2 TxD 2 11 TxD 2 TxD A 2 TxD 2 TxD Source 2 12 CTS 2 RTS B 2 RTS Ref 2 RxD 2 13 RxD 2 TxD B 2 TxD Ref 2 TxD 2 14 N C CTS A 2 CTS A 2 RxD Return 2 15 DTR 2 RxD A 2 RxD A 2 TxD Return 2 16 N C CTS B 2 CTS B 2 RxD Source 2 17 DCD 2 RxD B 2 RxD B 2 RxD 2 18 Ground 19 12 V 20 12 V 21 5 V 22 DCD 2 Tied high Tied high Tied high 23 CTS 2 Tied high 2...

Страница 81: ...he DFlex 4 104 adapter Figure 21 Current Loop wiring diagram 4 wire 1 8 2 7 RxD TxD RxD TxD 4 7 9 8 20mA 20mA TxD RxD RxD TxD 3 2 6 1 XMTR HCPL 4100 RCVR HCPL 4200 TxD Source TxD Return RxD Source RxD Return Optically isolated station Passive transmitters receivers Non isolated station Active transmitters receivers Port 1 DB 9 male Port 2 DB 9 male I SRC XMTR HCPL 4100 RCVR HCPL 4200 I SRC Note Th...

Страница 82: ...DFlex 4 104 User s Manual ver 0 04 ...

Отзывы: