1. Introduction

C1000 is a flexible keypad and Mifare reader in one unit for many different 

 

applications.

In standby the yellow LED is lit (

 ○ ○)

By correct code the yellow and the green LED lights (

 

 ○)

By incorrect code the red LED is lit (

○ ○ 

)

C1000 has a buzzer for indicating while keying, correct code, incorrect etc. and 2 tran

-

sistor outputs, independant from each other, so the C1000 can give access by code.

The C1000 is a stand alone unit, the can be programmed directly by Master code and 

Service code.

2. Installation

Mount the reader on a even surface. (use the following drill template for precise fit

-

ting).

Connect the wires to power supply, door strike, assembly board etc.

Colour scheme

Red:   

9 - 25V DC /30mA

Black:  

0V  GND

Yellow: 

Output 2 (open collector, max. 500mA) 0V active

White: 

Output 1 (open collector, max. 500mA) 0V active

Orange: 

External controlling red LED, 0V active

Green: 

External controlling green LED, 0V active

Blue:   

REX, 0V active

Brown: 

High security / external buzzer

Note: 

Right after applying the voltage all the LED’s lights and the buzzer sounds 

do not

 touch the reader untill the yellow LED lights and the buzzer is silent.

See connection examples on the last page.

Содержание 480000

Страница 1: ...Codetastatur C1000 Mykey Art Nr 480000 sort 480001 hvid Classic Art Nr 482000 sort 482001 hvid User manual C1000_usermanual_ENGjan20...

Страница 2: ...iguration of C1000 4 1 Service code 4 2 Configuration overview 4 3 Change the Master code 4 4 Change the Service code 4 5 LED Indications 4 6 Outputs 4 7 Special settings 5 Blocking 6 Manual reset 7 T...

Страница 3: ...Service code 2 Installation Mount the reader on a even surface use the following drill template for precise fit ting Connect the wires to power supply door strike assembly board etc Colour scheme Red...

Страница 4: ...utput 1 and 2 191 200 Reserved for special functions 3 2 Programming user codes The Master code is used to program change delete the users By default the Master code is 4711 LED indication No light Li...

Страница 5: ...oggles the output Ie the code is entered to unlock the door and entered to lock it again Programming the same user 3 times By programming the same code on the same position 3 times the output is desig...

Страница 6: ...s Key in a position and it counts automatically to the next position Codes can be programmed alternatively as you see fit For more codes tags repeat from here Note This programming mode overwrites exi...

Страница 7: ...00 goes back to the previous point and the next setting can be made The navigation is by entering the position value followed by 4 2 Configuration overview Position Setting Factory default 00 Master c...

Страница 8: ...normal adjust the LED s for correct code tag indication active adjust the keying indication how the LED will react while keying To adjust the LED s press on the following yellow LED toggle by press gr...

Страница 9: ...nds is the value automatically 0 which corresonds to set the output as toggle bonding the positions and output 1 bonding the positions and output 2 Both outputs are bonded to specific positions By fac...

Страница 10: ...codes and Mifare tags only activate output 2 High Security High Security increases the C1000 s security by ensuring 2 positions have to be activat ed before the output is activated the positions must...

Страница 11: ...lights and the buzzer sounds Turn the voltage off and disconnect the yellow and brown wire The C1000 is now reset to factory default and the user codes tags are deleted 7 Technical specifications Volt...

Страница 12: ...ED 0V active External controlling red LED 0V active CT 2000 Prox ALARM SYSTEM A S Prox 1 3 5 7 9 2 4 6 8 0 0V GND Doorstrike 12V DC 12V DC 0V GND Doorstrike 12V DC 12V DC 12V DC 0V DC REX 0V active Hi...

Отзывы: